ECS G82 Drilling with Dwell for chip breaking
The only difference between this cycle and the standard drilling G81 is the dwell done by the bit after it reached the Depth quote (ENT) to broken the chip.
The cycle Data Entry is activated, in MDI and Edit modes, through this keys sequence:
Programming
G82 <ENT=..> <RAP=..> <RAL=..> <TIM=..>
Parameters
Parameter | Description |
---|---|
ENT | Depth quote reached at working feed |
RAP | Quote reached in rapid at the beginning of cycle |
RAL | Quote reached in rapid at the end of the cycle |
TIM | Dwell at the ENT quote [sec]. |