Haas Alarm Codes (Error Codes) for CNC Machinists.
Haas Alarm Codes
- 101 – COMM. FAILURE WITH MOCON/MOCON MEMORY FAULT
- 102 – SERVOS OFF
- 103 – X SERVO ERROR TOO LARGE
- 104 – Y SERVO ERROR TOO LARGE
- 105 – Z SERVO ERROR TOO LARGE
- 106 – A SERVO ERROR TOO LARGE
- 107 – EMERGENCY OFF
- 108 – X SERVO OVERLOAD
- 109 – Y SERVO OVERLOAD
- 110 – Z SERVO OVERLOAD
- 111 – A SERVO OVERLOAD
- 112 – NO INTERRUPT
- 113 – TURRET UNLOCK FAULT – Haas Lathe
- 113 – SHUTTLE IN FAULT – Haas Mill
- 114 – TURRET LOCK FAULT – Haas Lathe
- 114 – SHUTTLE OUT FAULT – Haas Mill
- 115 – TURRET ROTATE FAULT – Haas Lathe
- 115 – TURRET ROTATE FAULT – Haas Mill
- 116 – SPINDLE ORIENTATION FAULT
- 117 – SPINDLE HIGH GEAR FAULT
- 118 – SPINDLE LOW GEAR FAULT
- 119 – OVERVOLTAGE
- 120 – LOW AIR PRESSURE
- 121 – LOW LUBE OR LOW PRESSURE
- 122 – REGEN OVERHEAT
- 123 – SPINDLE DRIVE FAULT
- 124 – LOW BATTERY
- 125 – TOOL TURRET FAULT – Haas Lathe
- 125 – SHUTTLE FAULT – Haas Mill
- 126 – GEAR FAULT
- 127 – DOOR FAULT – Haas Lathe
- 127 – NO TURRET MARK – Haas Mill
- 128 – SUPER TRAVEL ENABLED ON MULTIPLE AXES – Haas Mill
- 129 – M FIN FAULT
- 130 – CHUCK UNCLAMPED – Haas Lathe
- 130 – TOOL UNCLAMPED – Haas Mill
- 131 – TOOL NOT CLAMPED – Haas Mill
- 132 – POWER DOWN FAILURE
- 133 – SPINDLE BRAKE ENGAGED – Haas Lathe
- 133 – SPINDLE INOPERATIVE – Haas Mill
- 134 – LOW HYDRAULIC PRESSURE – Haas Lathe
- 134 – TOOL CLAMP FAULT – Haas Mill
- 135 – X-AXIS MOTOR OVERHEAT
- 136 – Y-AXIS MOTOR OVERHEAT
- 137 – Z-AXIS MOTOR OVERHEAT
- 138 – A-AXIS MOTOR OVERHEAT
- 139 – X-AXIS MOTOR Z FAULT
- 140 – Y-AXIS MOTOR Z FAULT
- 141 – Z-AXIS MOTOR Z FAULT
- 142 – A-AXIS MOTOR Z FAULT
- 143 – SPINDLE ORIENTATION LOST – Haas Lathe
- 143 – SPINDLE ORIENTATION LOST – Haas Mill
- 144 – TIMEOUT – CALL YOUR DEALER
- 145 – X LIMIT SWITCH
- 146 – Y LIMIT SWITCH
- 147 – Z LIMIT SWITCH
- 148 – A LIMIT SWITCH
- 149 – SPINDLE TURNING – Haas Lathe
- 149 – SPINDLE TURNING – Haas Mill
- 150 – I_MODE OUT OF RANGE – Haas Lathe
- 150 – Z AND TOOL INTERLOCKED – Haas Mill
- 151 – HPC LOW PRESSURE – Haas Lathe
- 151 – LOW THRU SPINDLE COOLANT – Haas Mill
- 152 – SELF TEST FAIL
- 153 – X AXIS Z CH MISSING
- 154 – Y AXIS Z CH MISSING
- 155 – Z AXIS Z CH MISSING
- 156 – A AXIS Z CH MISSING
- 157 – MOCON WATCHDOG FAULT
- 158 – VIDEO/KEYBOARD PCB FAILURE
- 159 – KEYBOARD FAILURE
- 160 – LOW VOLTAGE – Haas Lathe
- 160 – LOW VOLTAGE – Haas Mill
- 161 – X AXIS DRIVE FAULT
- 162 – Y AXIS DRIVE FAULT
- 163 – Z AXIS DRIVE FAULT
- 164 – A AXIS DRIVE FAULT
- 165 – X ZERO RET MARGIN TOO SMALL
- 166 – Y ZERO RET MARGIN TOO SMALL
- 167 – Z ZERO RET MARGIN TOO SMALL
- 168 – A ZERO RET MARGIN TOO SMALL
- 169 – SPINDLE DIRECTION FAULT
- 170 – ENABLED AXIS NEEDS MOCON2 – Haas Mill
- 171 – rpm TOO HIGH TO UNCLAMP – Haas Lathe
- 171 – APC-PALLET CLAMP TIMEOUT – Haas Mill
- 172 – DOOR IS OPEN AND SPINDLE IS TURNING – Haas Lathe
- 172 – APC-PALLET UNCLAMP TIMEOUT – Haas Mill
- 173 – SPINDLE ENCODER Z CH MISSING
- 174 – TOOL LOAD EXCEEDED – Haas Lathe
- 174 – TOOL LOAD EXCEEDED – Haas Mill
- 175 – GROUND FAULT DETECTED
- 176 – OVERHEAT SHUTDOWN
- 177 – OVERVOLTAGE SHUTDOWN
- 178 – DIVIDE BY ZERO
- 179 – LOW PRESSURE TRANS OIL
- 180 – PALLET/FIXTURE NOT CLAMPED – Haas Mill
- 181 – MACRO NOT COMPLETED – SPINDLE DISABLED
- 182 – X CABLE FAULT
- 183 – LIVE TOOLING CABLE FAULT – Haas Lathe
- 183 – Y CABLE FAULT – Haas Mill
- 184 – Z CABLE FAULT
- 185 – A CABLE FAULT
- 186 – SPINDLE NOT TURNING
- 187 – B SERVO ERROR TOO LARGE – Haas Lathe
- 187 – B SERVO ERROR TOO LARGE – Haas Mill
- 188 – B SERVO OVERLOAD
- 189 – B-AXIS MOTOR OVERHEAT
- 190 – B MOTOR Z FAULT
- 191 – B LIMIT SWITCH
- 192 – B AXIS Z CH MISSING
- 193 – B AXIS DRIVE FAULT
- 194 – B ZERO RET MARGIN TOO SMALL
- 195 – B CABLE FAULT
- 196 – COOLANT SPIGOT FAILURE – Haas Mill
- 197 – MISC. SOFTWARE ERROR
- 198 – SPINDLE STALLED
- 199 – NEGATIVE rpm