Haas Alarm: 303 INVALID X,B OR Z IN G02 OR G03 – Haas Lathe


Alarm: 303 INVALID X,B OR Z IN G02 OR G03 – Haas Lathe

Haas Alarm Description:
Intersection points in G02 and G03 start and end must have an accuracy of 0.0010 inches (0.010 mm.). Check your geometry.

References

  1. Haas Alarms PDF by Haas Automation, Inc.