Alarm: 336 A AXIS DISABLED – Haas Mill
Haas Alarm Description:
Attempt was made to program the A-axis while it was disabled (Disabled bit in Parameter 43 set to 1), invisible (Invis Axis bit in Parameter 43 set to 1), or a program commanded the A-axis while it was the outside rotary table (Rotary Index button feature, Map 4TH Axis bit in Parameter 315 set to 1).
References
- Haas Alarms PDF by Haas Automation, Inc.