Alarm: 392 B AXIS DISABLED – Haas Mill
Haas Alarm Description:
Attempt made to program the B-axis while it was disabled (Disabled bit in Parameter 151 set to 1), invisible (Invis Axis bit in Parameter 151 set to 1), or program commanded the B-axis while it was the outside rotary table (Rotary Index button feature, Map 4TH Axis bit in Parameter 315 set to 1).