Haas Setting 109 Warmup Time in Min.


Haas Setting 109 Warmup Time in Min.

Haas Setting Description
This is the number of minutes (up to 300 minutes from power-up) during which the compensations specified in Settings 110-112 are applied.

Overview – When the machine is powered on, if Setting 109, and at least one of Settings 110, 111 or 112, are set to a nonzero value, the following warning will be displayed:

CAUTION! Warm up Compensation is specified!
Do you wish to activate
Warm up Compensation (Y/N)?

If a ‘Y’ is entered, the control immediately applies the total compensation (setting 110,111, 112), and the compensation begins to decrease as the time elapses. For instance, after 50% of the time in Setting 109 has elapsed, the compensation distance, will be 50%.

To “restart” the time period, it is necessary to power the machine off and on, and then answer “yes” to the compensation query at start-up.

Caution: Changing settings 110, 111 or 112 while compensation is in progress can cause a sudden movement of up to 0.0044 inch.

The amount of remaining warm up time is displayed on the bottom right hand corner of the Diagnostics Inputs 2 screen using the standard hh:mm:ss format.

References

  1. Haas Lathe Operator’s Manual by Haas Automation, Inc.
  2. Haas Mill Operator’s Manual by Haas Automation, Inc.
Haas Setting 109 Warmup Time in Min.