Haas Setting Description
This setting is the minimum allowable difference between the Z-axis and the tail stock (see Setting 93). Units are in inches. A value of -1.0000 means that when the X-axis is below the X clearance plane (Setting 93), the Zaxis must be more than 1 inch away from the tail stock position in the Z-axis negative direction. The default value for this setting is zero. Units are in inches.
References
- Haas Lathe Operator’s Manual by Haas Automation, Inc.