Sinumerik Alarm 4034 Local link axis %1 is not allowed for different interpolation cycle time = %2/%3


Sinumerik Alarm 4034 Local link axis %1 is not allowed for different interpolation cycle time = %2/%3

Parameters:
%1 = Axis name
%2 = Local interpolation cycle
%3 = Max. interpolation cycle

Definitions:
Local link axes are only permissible on an NCU if the interpolation cycle set corresponds to the slowest interpolation cycle of the interconnected NCU systems.

Reactions:
– Alarm display.
– Interface signals are set.
– NC not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.

Remedy:
Remove local link axis (see MN_AXCONF_MACHAX_NAME_TAB and MN_AXCT_AXCONF_ASSIGN_TAB1) or adapt the interpolation cycle (MN_IPO_SYSCLOCK_TIME_RATIO).

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 4034 Local link axis %1 is not allowed for different interpolation cycle time = %2/%3