Sinumerik Alarm 4180 Invalid M function number assigned to enable ASUP


Sinumerik Alarm 4180 Invalid M function number assigned to enable ASUP

Definitions:
An invalid M function number has been assigned for activation of ASUP. An illegal M number has been assigned in machine data $MN_EXTERN_M_NO_SET_INT or $MN_EXTERN_M_NO_DISABLE_INT for the configuration of the M number range for activation/deactivation of the interrupt program.

Reactions:
– Alarm display.
– Interface signals are set.
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.

Remedy:
Check machine data $MN_EXTERN_ M_NO_SET_INT and $MN_EXTERN_M_NO_DISABLE_INT.

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens