Sinumerik Alarm 4340 Channel %1 block %2 invalid transformation type in transformation no. %3


Sinumerik Alarm 4340 Channel %1 block %2 invalid transformation type in transformation no. %3

Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Transformation number

Definitions:
An invalid, i.e. undefined, number was entered in one of the machine data TRAFO_TYPE_1 … TRAFO_TYPE_8. This alarm also occurs if a certain type of transformation is only impossible on the type of control used (e.g. 5-axis transformation on a SINUMERIK 802D).

Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.
– NC Stop on alarm at block end.

Remedy:
Enter a valid transformation type.

Program Continuation:
Clear alarm with the RESET key. Restart part program

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 4340 Channel %1 block %2 invalid transformation type in transformation no. %3