Sinumerik Alarm 10707 Channel %1 channel-specific protection zone %2 reached with axis %3 during manual mode
Parameters:
%1 = Channel number
%2 = Protection zone number
%3 = Axis name
Definitions:
The work piece-related channel-specific protection zone has been reached with the specified axis. Note that another tool-related protection zone is still active. The work piece related protection zone can be traversed when the PLC has issued an enable signal.
Reactions:
– Alarm display.
– Interface signals are set.
– Local alarm reaction.
Remedy:
Please inform the authorized personnel/service department. Protection zone can be traversed after enable signal from PLC.
Program Continuation:
Alarm display showing cause of alarm disappears. No further operator action
References
- Siemens Diagnostics Guide by Siemens