Sinumerik Alarm 10745 Channel %1 block %2 WAB end position not clear
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In the WAB block and in the following block, the position has been programmed perpendicular to the machining direction. In the WAB block, no position has been indicated in the machining plane.
Reactions:
– Local alarm reaction.
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.
– NC Stop on alarm at block end.
Remedy:
Modify part program. Either remove the position data for the infeed axis from the WAB block or the following block, or program a position in the machining plane in the WAB block as well.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
References
- Siemens Diagnostics Guide by Siemens