Sinumerik Alarm 10931 Channel %1 block %2 incorrect stock removal contour
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The following errors occurred in the subroutine for the contour during stock removal:
• Full circle
• Overlapping contour elements
• Wrong start position
Reactions:
– Local alarm reaction.
– Alarm display.
– Interface signals are set.
– NC Start disable in this channel.
Remedy:
The errors listed above must be corrected in the subroutine for the stock removal contour.
Program Continuation:
Clear alarm with the RESET key. Restart part program
References