Sinumerik Alarm 10940 Channel %1 block %2 curve table %3: delete/overwrite not possible
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
Definitions:
The curve table can only be deleted if it is not active in a link.
Reactions:
– Alarm display.
– Interface signals are set.
– Interpreter stop
– NC Start disable in this channel.
Remedy:
It is necessary to deactivate all links that are being used by the curve table to be deleted.
Program Continuation:
Clear alarm with the RESET key. Restart part program
References
- Siemens Diagnostics Guide by Siemens