Sinumerik Alarm 14033 Channel %1 block %2 involute: no end point programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No end point was programmed for the involute. This is either possible via direct programming with the geometry axis identifiers or by specifying the angle between start and end vector.
Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.
Remedy:
Modify part program.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
References
- Siemens Diagnostics Guide by Siemens