Sinumerik Alarm 14290 Channel %1 block %2 poly nominal degree greater than 5 programmed for poly nominal interpolation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A poly nominal degree greater than five was programmed for the poly nominal interpolation. You can only program polynomials up to the 5th degree.
Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.
Remedy:
Modify part program.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
References
- Siemens Diagnostics Guide by Siemens