Centroid Alarms

Centroid Alarms, Errors Messages

Centroid Alarm 1005 Cannot scale arcs with different scale factors

Centroid Alarm 1005 Cannot scale arcs with different scale factors Cause & Effect Scaling factors of the arc axes are different. Job cancelled. Action Correct scaling factors, or separate scaling…

Centroid Alarm 1004 Turn scaling off before rescaling

Centroid Alarm 1004 Turn scaling off before rescaling Cause & Effect Tried to rescale while scaling is turned on. Job cancelled. Action Turn scaling off, then rescale.

Centroid Alarm 1003 G-code not allowed when scaling on line NNNNN

Centroid Alarm 1003 G-code not allowed when scaling on line NNNNN Cause & Effect G28/G29/G30/G92 is not allowed when scaling or mirroring is turned on. Job cancelled. Action Move G-code…

Centroid Alarm 1002 Invalid scaling center on line NNNNN

Centroid Alarm 1002 Invalid scaling center on line NNNNN Cause & Effect Invalid parameter specified (X, Y, Z). Job cancelled. Action Remove or change invalid parameter.

Centroid Alarm 1001 Invalid scaling parameter on line NNNNN

Centroid Alarm 1001 Invalid scaling parameter on line NNNNN Cause & Effect Invalid parameter specified (I, J, K, P). Job cancelled. Action Remove or change invalid parameter.

Centroid Alarm 807 Error: Cannot execute G__ when axis B is rotated

Centroid Alarm 807 Error: Cannot execute G__ when axis B is rotated Cause & Effect On an Articulated Head machine with TWCS feature enabled, a non-compound canned cycle (such as…

Centroid Alarm 487 Invalid tilt table parameters

Centroid Alarm 487 Invalid tilt table parameters Cause & Effect One or more values in the tilt table configuration is incorrect. Action Contact Dealer.

Centroid Alarm 462 Triangular Rotary Axis Out of Range

Centroid Alarm 462 Triangular Rotary Axis Out of Range Cause & Effect A triangular rotary axis (on a tilt table or articulated head machine) is at a position which is…

Centroid Alarm 453 Jogging while probe detected

Centroid Alarm 453 Jogging while probe detected Cause & Effect The probe was in the tripped state while a jog key was pressed.

Centroid Alarm 949 Drive map does not match hardware

Centroid Alarm 949 Drive map does not match hardware Cause & Effect One or more of the drive mapping parameters 300-307 is misconfigured Action Contact Dealer.

Centroid Alarm 948 PC packet error

Centroid Alarm 948 PC packet error Cause & Effect The PC received bad data from the MPU and will try to recover by requesting a resend. Action Status Message

Centroid Alarm 947 PC received data out of order

Centroid Alarm 947 PC received data out of order Cause & Effect The PC needed to reorder data received from the MPU Action Status Message

Centroid Alarm 946 PC resending

Centroid Alarm 946 PC resending Cause & Effect The PC is resending Action Status Message

Centroid Alarm 945 PC requested resend

Centroid Alarm 945 PC requested resend Cause & Effect The PC requested a resend Action Status Message

Centroid Alarm 944 MPU requested resend

Centroid Alarm 944 MPU requested resend Cause & Effect The MPU requested a resend Action Status Message

Centroid Alarm 936 _ axis (#) scale enabled

Centroid Alarm 936 _ axis (#) scale enabled Cause & Effect A scale is enabled for this axis and compensation was enabled. This happens after homing the axis. Action Not…

Centroid Alarm 935 _ axis (#) scale disabled

Centroid Alarm 935 _ axis (#) scale disabled Cause & Effect A scale is enabled for this axis but compensation was disabled. Scale compensation is disabled at initial power up,…

Centroid Alarm 934 Warning: Excess precision truncated

Centroid Alarm 934 Warning: Excess precision truncated Cause & Effect A CNC program is using axis positioning precision greater than what is displayed, and therefore the actual commanded positions are…

Centroid Alarm 933 Log file initialized

Centroid Alarm 933 Log file initialized Cause & Effect There was an error in trimming the log file, or the log file did not exist, so a new log file…

Centroid Alarm 932 Error during Tool Check

Centroid Alarm 932 Error during Tool Check Cause & Effect A general error condition occurred when the Tool Check key was pressed.

Centroid Alarm 930 Log Level Configuration file not found… Creating new configuration

Centroid Alarm 930 Log Level Configuration file not found… Creating new configuration Cause & Effect The log level configuration file was not found. A default file will be created. Action…

Centroid Alarm 929 Log Level set to __

Centroid Alarm 929 Log Level set to __ Cause & Effect The logging level parameter (P140) has been changed.

Centroid Alarm 928 Error Loading Log Configuration file… Using defaults

Centroid Alarm 928 Error Loading Log Configuration file… Using defaults Cause & Effect There was an error while loading the log configuration file. Default settings will be used.

Centroid Alarm 927 Too many subprogram calls

Centroid Alarm 927 Too many subprogram calls Cause & Effect Nesting level of subprograms is too high. I.e. a subprogram calls another subprogram which calls another subprogram, which calls another…

Centroid Alarm 926 Failed to locate job continuation position

Centroid Alarm 926 Failed to locate job continuation position Cause & Effect Job continuation from the Run Menu failed. Action Do a Run/Search

Centroid Alarm 925 Error reading job file

Centroid Alarm 925 Error reading job file Cause & Effect same as above at a different place in the code

Centroid Alarm 924 File read error

Centroid Alarm 924 File read error Cause & Effect Problem reading the job file, this error occurs if the file was opened successfully but there was an error while reading…

Centroid Alarm 922 Out of memory

Centroid Alarm 922 Out of memory Cause & Effect problem allocating memory

Centroid Alarm 920 Unable to clear obstacle

Centroid Alarm 920 Unable to clear obstacle Cause & Effect Probing cycle failed to clear an obstacle

Centroid Alarm 919 DSP window failed maximum retries

Centroid Alarm 919 DSP window failed maximum retries Cause & Effect DSP probe reached the maximum retry limit without a successful window

Centroid Alarm 918 Probe unable to detect surface

Centroid Alarm 918 Probe unable to detect surface Cause & Effect Probe travelled maximum distance without contact, dsp window checking failed, or probe repeatability failed.

Centroid Alarm 917 Invalid tilt lookup table

Centroid Alarm 917 Invalid tilt lookup table Cause & Effect The tilt lookup table file (tilt.tab) has an invalid format or if it is not found

Centroid Alarm 916 Unexpected probe contact

Centroid Alarm 916 Unexpected probe contact Cause & Effect probed tripped when a cycle did not expected contact

Centroid Alarm 915 DSP window retry sN fN rN

Centroid Alarm 915 DSP window retry sN fN rN Cause & Effect DSP window checking failed, move will be repeated unless the maximum retries have been reached, s = number…

Centroid Alarm 913 Could not open file filename.ext

Centroid Alarm 913 Could not open file filename.ext Cause & Effect Attempt to call a subprogram or macro, but the subprogram file does not exist. Job cancelled. Action Make sure…

12345...