Haas Alarms

Haas Alarms – Haas Alarm Codes with description.

Haas Alarm 949 APC-AXIS VISIBLE – Haas Mill

Alarm: 949 APC-AXIS VISIBLE – Haas Mill Haas Alarm Description: The pallet changer axis must be invisible for the pallet changer to operate. Set the parameter bit Invis Axis to…

Haas Alarm 948 APC-SOFTWARE ERROR – Haas Mill

Alarm: 948 APC-SOFTWARE ERROR – Haas Mill Haas Alarm Description: Fault in pallet changer software. Note the actions that caused this alarm. Also record the following information: On the control…

Haas Alarm 947 APC-PALLET UNCLAMP TIMEOUT – Haas Mill

Alarm: 947 APC-PALLET UNCLAMP TIMEOUT – Haas Mill Haas Alarm Description: The pallet in the mill did not unclamp in the time allowed. Check for foreign objects between the pallet…

Haas Alarm 946 APC-PALLET CLAMP TIMEOUT – Haas Mill

Alarm: 946 APC-PALLET CLAMP TIMEOUT – Haas Mill Haas Alarm Description: The pallet in the mill did not clamp in the time allowed. Check for foreign objects under the pallet…

Haas Alarm 945 APC-LIFT FRAME DOWN TIMEOUT – Haas Mill

Alarm: 945 APC-LIFT FRAME DOWN TIMEOUT – Haas Mill Haas Alarm Description: The pallet changer was commanded to lower but the down position switch was not contacted before the timeout…

Haas Alarm 944 INDEXER OUT OF POSITION – Haas Mill

Alarm: 944 INDEXER OUT OF POSITION – Haas Mill Haas Alarm Description: The A-axis indexer is out of position. Jog A-axis to within 1° of a clamping position before running…

Haas Alarm 943 UNPROCESSED QUEUE CELL IN TOOL CHANGE – Haas Mill

Alarm: 943 UNPROCESSED QUEUE CELL IN TOOL CHANGE – Haas Mill Haas Alarm Description: There is an unknown command generated in the Tool change. Please save your current program to…

Haas Alarm 942 CAROUSEL POSITION TIMEOUT – Haas Mill

Alarm: 942 CAROUSEL POSITION TIMEOUT – Haas Mill Haas Alarm Description: This alarm is generated by the tool changer if the tool carousel has not moved after the allowed time…

Haas Alarm 941 POCKET-TOOL TABLE ERROR – Haas Mill

Alarm: 941 POCKET-TOOL TABLE ERROR – Haas Mill Haas Alarm Description: This alarm is generated by the tool changer if the tool specified by the program is not found in…

Haas Alarm 940 SIDE MOUNT CAROUSEL ERROR – Haas Mill

Alarm: 940 SIDE MOUNT CAROUSEL ERROR – Haas Mill Haas Alarm Description: This alarm is generated by the tool changer if the carousel motor is still running when the tool…

Haas Alarm 939 LANGUAGES FAILED TO LOAD

Alarm: 939 LANGUAGES FAILED TO LOAD Haas Alarm Description: Foreign languages failed to be loaded into the control. Languages either exceeded total flash memory, or not enough flash memory available….

Haas Alarm 938 LANGUAGES LOADED

Alarm: 938 LANGUAGES LOADED Haas Alarm Description: Foreign languages were recently loaded into the control.

Haas Alarm 937 INPUT LINE POWER FAULT

Alarm: 937 INPUT LINE POWER FAULT Haas Alarm Description: Input line power failed. This alarm will be generated whenever incoming power to machine falls below reference voltage value in Parameter…

Haas Alarm 935 BAR 100 FAULT – Haas Lathe

Alarm: 935 BAR 100 FAULT – Haas Lathe Haas Alarm Description: Bar 100 program error. Cycle power on the machine. If the alarm reoccurs, call your dealer and report the…

Haas Alarm 934 BAR 100- CURRENT BAR FINISHED – Haas Lathe

Alarm: 934 BAR 100- CURRENT BAR FINISHED – Haas Lathe Haas Alarm Description: Load new bar. Reset alarm and press Cycle Start to continue.

Haas Alarm 933 BAR 100- MAXIMUM PARTS COMPLETED – Haas Lathe

Alarm: 933 BAR 100- MAXIMUM PARTS COMPLETED – Haas Lathe Haas Alarm Description: Job Completed. To Continue, reset #3103 Max # Parts and/or #3106 Current # Parts Run on the…

Haas Alarm 932 BAR 100- ZERO VALUE – Haas Lathe

Alarm: 932 BAR 100- ZERO VALUE – Haas Lathe Haas Alarm Description: You must enter a value for #3100 Part Length + Cutoff, #3102 Min Clamping Length and #3109 Length…

Haas Alarm 927 ILLEGAL G1 CODE FOR ROTARY INDEXER – Haas Mill

Alarm: 927 ILLEGAL G1 CODE FOR ROTARY INDEXER – Haas Mill Haas Alarm Description: The rotary indexer only does rapid G0 motion. Feed G1 motion is not allowed.

Haas Alarm 926 B INDEXER IS NOT FULLY IN THE UP POSITION – Haas Mill

Alarm: 926 B INDEXER IS NOT FULLY IN THE UP POSITION – Haas Mill Haas Alarm Description: The indexer is still seated. It is not completely in the up position…

Haas Alarm 925 A INDEXER IS NOT FULLY IN THE UP POSITION – Haas Mill

Alarm: 925 A INDEXER IS NOT FULLY IN THE UP POSITION – Haas Mill Haas Alarm Description: The indexer is still seated. It is not completely in the up position…

Haas Alarm 924 B INDEXER IS NOT AT THE PROPER INCREMENTAL POSITION – Haas Mill

Alarm: 924 B INDEXER IS NOT AT THE PROPER INCREMENTAL POSITION – Haas Mill Haas Alarm Description: The indexer has moved to a position that cannot be seated.

Haas Alarm 924 SS LOW LUBE OR LOW PRESSURE – Haas Lathe

Alarm: 924 SS LOW LUBE OR LOW PRESSURE – Haas Lathe Haas Alarm Description: Way lube is low or empty or there is no lube pressure or too high a…

Haas Alarm 923 A INDEXER IS NOT AT THE PROPER INCREMENTAL POSITION – Haas Mill

Alarm: 923 A INDEXER IS NOT AT THE PROPER INCREMENTAL POSITION – Haas Mill Haas Alarm Description: The indexer has moved to a position that cannot be seated.

Haas Alarm 923 LOW OIL PRESSURE – Haas Lathe

Alarm: 923 LOW OIL PRESSURE – Haas Lathe Haas Alarm Description: Oil Pump for platter gear has no pressure. Check that pump is pumping oil through lines. Check to make…

Haas Alarm 922 APC-TABLE NOT DECLARED – Haas Mill

Alarm: 922 APC-TABLE NOT DECLARED – Haas Mill Haas Alarm Description: Software calling invalid tables. Software Error; call your dealer.

Haas Alarm 921 APC LOAD-SWITCH MISSED PAL 4 – Haas Mill

Alarm: 921 APC LOAD-SWITCH MISSED PAL 4 – Haas Mill Haas Alarm Description: Pallet #4 did not complete its move from the APC to the receiver in the allowable time….

Haas Alarm 920 APC LOAD-SWITCH MISSED PAL 3 – Haas Mill

Alarm: 920 APC LOAD-SWITCH MISSED PAL 3 – Haas Mill Haas Alarm Description: Pallet #3 did not complete its move from the APC to the receiver in the allowable time….

Haas Alarm 919 APC LOAD-SWITCH MISSED PAL 2 – Haas Mill

Alarm: 919 APC LOAD-SWITCH MISSED PAL 2 – Haas Mill Haas Alarm Description: Pallet #2 did not complete its move from the APC to the receiver in the allowable time….

Haas Alarm 918 APC LOAD-SWITCH MISSED PAL 1 – Haas Mill

Alarm: 918 APC LOAD-SWITCH MISSED PAL 1 – Haas Mill Haas Alarm Description: Pallet #1 did not complete its move from the APC to the receiver in the allowable time….

Haas Alarm 917 APC-NUMBER OF PALLETS IS ZERO – Haas Mill

Alarm: 917 APC-NUMBER OF PALLETS IS ZERO – Haas Mill Haas Alarm Description: Parameter 606 must have a value if Parameter 605 is not zero. Set Parameter 606 to the…

Haas Alarm 916 APC-NEGATIVE PAL PRIORITY INDEX – Haas Mill

Alarm: 916 APC-NEGATIVE PAL PRIORITY INDEX – Haas Mill Haas Alarm Description: Software Error; call your dealer.

Haas Alarm 915 APC-ILLEGAL NESTING G188 or M48 – Haas Mill

Alarm: 915 APC-ILLEGAL NESTING G188 or M48 – Haas Mill Haas Alarm Description: G188 is only legal in main program. M48 is only legal in a program listed in the…

Haas Alarm 914 APC-INVALID P CODE – Haas Mill

Alarm: 914 APC-INVALID P CODE – Haas Mill Haas Alarm Description: The P code must be the name of a program stored in memory. The program name must not have…

Haas Alarm 913 APC-NO P CODE OR Q CODE FOR M49 – Haas Mill

Alarm: 913 APC-NO P CODE OR Q CODE FOR M49 – Haas Mill Haas Alarm Description: M49 must have a Q code. The P code is the pallet number. The…

Haas Alarm 912 APC-NO P CODE OR Q CODE FOR M46 – Haas Mill

Alarm: 912 APC-NO P CODE OR Q CODE FOR M46 – Haas Mill Haas Alarm Description: M46 must have a P code and a Q code. The P code must…