Haas Alarm: 602 NON-MONOTONOUS PQ BLOCKS IN X – Haas Lathe

Alarm: 602 NON-MONOTONOUS PQ BLOCKS IN X – Haas Lathe Haas Alarm Description: The path defined by PQ was not monotonic in the X-axis. A monotonic Path is one that…

Haas Alarm: 601 V OVER TRAVEL RANGE – Haas Mill

Alarm: 601 V OVER TRAVEL RANGE – Haas Mill Haas Alarm Description: Commanded V-axis move would exceed the allowed machine range. Machine coordinates are in the negative direction. This indicates…

Haas Alarm: 601 MAXIMUM PQ BLOCKS EXCEEDED – Haas Lathe

Alarm: 601 MAXIMUM PQ BLOCKS EXCEEDED – Haas Lathe Haas Alarm Description: The maximum number of blocks making up a PQ sequence was exceeded. Currently, no more than 65535 blocks…

Haas Alarm: 600 U OVER TRAVEL RANGE – Haas Mill

Alarm: 600 U OVER TRAVEL RANGE – Haas Mill Haas Alarm Description: Commanded U-axis move would exceed allowed machine range. Machine coordinates are in the negative direction. This indicates either…

Haas Alarm: 600 CODE NOT EXPECTED IN THIS CONTEXT – Haas Lathe

Alarm: 600 CODE NOT EXPECTED IN THIS CONTEXT – Haas Lathe Haas Alarm Description: During program interpretation, the control found code out of context. This may indicate an invalid address…

Haas Alarm: 542 OPERATION NOT AVAILABLE

Alarm: 542 OPERATION NOT AVAILABLE Haas Alarm Description: This operation is not compatible with FNC mode.

Haas Alarm: 541 MACRO ALARM

Alarm: 541 MACRO ALARM Haas Alarm Description: This alarm was generated by a macro command in a program.

Haas Alarm: 540 MACRO SYNTAX NOT ALLOWED

Alarm: 540 MACRO SYNTAX NOT ALLOWED Haas Alarm Description: A section of code was interpreted by the control where macro statement syntax is not permitted. In lathe controls, PQ sequences…

Haas Alarm: 539 ILLEGAL GOTO

Alarm: 539 ILLEGAL GOTO Haas Alarm Description: Macro statement includes an expression after GOTO that is not valid.

Haas Alarm: 538 MATCHING END NOT FOUND

Alarm: 538 MATCHING END NOT FOUND Haas Alarm Description: While-Do statement does not contain a matching “End” statement. Add the proper “End” statement.

Haas Alarm: 537 RS-232 ABORT ON DPRNT

Alarm: 537 RS-232 ABORT ON DPRNT Haas Alarm Description: While a DPRNT statement was executing, the RS-232 communications failed. Check to see that PC is ready to receive with port…

Haas Alarm: 536 COMMAND FOUND ON DPRNT LINE

Alarm: 536 COMMAND FOUND ON DPRNT LINE Haas Alarm Description: A G-code was included on a DPRNT block. Make two separate blocks, only DPRNT statement on block allowed. Check macro…

Haas Alarm: 535 ILLEGAL DPRNT STATEMENT

Alarm: 535 ILLEGAL DPRNT STATEMENT Haas Alarm Description: A DPRNT statement has been formatted improperly, or DPRNT does not begin block. Check format of DPRNT statements.

Haas Alarm: 534 DO OR END ALREADY IN USE

Alarm: 534 DO OR END ALREADY IN USE Haas Alarm Description: Multiple use of a DO that has not been closed by an END in the same subroutine. Close condition…

Haas Alarm: 533 MACRO VARIABLE UNDEFINED

Alarm: 533 MACRO VARIABLE UNDEFINED Haas Alarm Description: A conditional expression evaluated to an UNDEFINED value, i.e. #0. Return True or False. Check macro formatting.

Haas Alarm: 532 UNKNOWN CODE IN POCKET PATTERN

Alarm: 532 UNKNOWN CODE IN POCKET PATTERN Haas Alarm Description: Macro syntax is not allowed in a pocket pattern subroutine. Check macro formatting.

Haas Alarm: 531 MACRO NESTING TOO DEEP

Alarm: 531 MACRO NESTING TOO DEEP Haas Alarm Description: Only nine levels of macro nesting can occur when using G65. Reduce the number of nested macro calls.

Haas Alarm: 530 TOO MANY I, J, or K’S IN G65

Alarm: 530 TOO MANY I, J, or K’S IN G65 Haas Alarm Description: Only 10 occurrences of I, J, or K can occur in a G65 subroutine call. Reduce the…

Haas Alarm: 529 ILLEGAL G65 PARAMETER

Alarm: 529 ILLEGAL G65 PARAMETER Haas Alarm Description: Alphabetic addresses G, L, N, O, and P cannot be used to pass variables. See Operator manual macro section for valid variables.Select…

Haas Alarm: 528 PARAMETER PRECEDES G65

Alarm: 528 PARAMETER PRECEDES G65 Haas Alarm Description: On G65 lines, all parameters must follow the G65 G-code. Place parameters after G65.

Haas Alarm: 527 = NOT EXPECTED OR THEN REQUIRED

Alarm: 527 = NOT EXPECTED OR THEN REQUIRED Haas Alarm Description: Only one assignment is allowed per block, or a THEN statement is missing. Check macro formatting.

Haas Alarm: 526 COMMAND FOUND ON DO/END LINE

Alarm: 526 COMMAND FOUND ON DO/END LINE Haas Alarm Description: A G-code command was found on a While-Do or End macro block. Move the G-code to a separate block.

Haas Alarm: 525 VAR. REF. ILLEGAL DURING MOVEMENT

Alarm: 525 VAR. REF. ILLEGAL DURING MOVEMENT Haas Alarm Description: Variable cannot be read during axis movement.

Haas Alarm: 524 END FOUND WITH NO MATCHING DO

Alarm: 524 END FOUND WITH NO MATCHING DO Haas Alarm Description: An END was encountered without encountering a previous matching DO. DO-END numbers must agree. Check macro formatting.

Haas Alarm: 523 CONDITIONAL REQUIRED PRIOR TO THEN

Alarm: 523 CONDITIONAL REQUIRED PRIOR TO THEN Haas Alarm Description: A THEN was encountered and a conditional statement was not processed in the same block. Check macro formatting.

Haas Alarm: 522 ILLEGAL ASSIGNMENT VAR OR VALUE

Alarm: 522 ILLEGAL ASSIGNMENT VAR OR VALUE Haas Alarm Description: A variable was referenced for writing. The variable referenced is read only. See Operator manual macro section for valid variables….

Haas Alarm: 521 ILLEGAL FUNCTIONAL PARAMETER

Alarm: 521 ILLEGAL FUNCTIONAL PARAMETER Haas Alarm Description: An illegal value was passed to a function, such as SQRT[ orASIN[. Check macro formatting.

Haas Alarm: 520 OPERATOR EXPECTED

Alarm: 520 OPERATOR EXPECTED Haas Alarm Description: In the evaluation of a macro expression, an operator was expected but not found. Check macro formatting.

Haas Alarm: 519 TERM EXPECTED

Alarm: 519 TERM EXPECTED Haas Alarm Description: In the evaluation of a macro expression, an operand was expected but not found.Check macro formatting.

Haas Alarm: 518 ILLEGAL MACRO EXPRESSION REFERENCE

Alarm: 518 ILLEGAL MACRO EXPRESSION REFERENCE Haas Alarm Description: Alphabetic addresses N and O are illegal variables.You cannot declare N#1, etc. See Operator manual macro section for valid variables.

Haas Alarm: 517 EXPRSN. NOT ALLOWED WITH N OR O

Alarm: 517 EXPRSN. NOT ALLOWED WITH N OR O Haas Alarm Description: Alphabetic addresses N and O are illegal variables. You cannot declare N#1, etc. See Operator manual macro section…

Haas Alarm: 516 ILLEGAL CONDITIONAL OR NO THEN

Alarm: 516 ILLEGAL CONDITIONAL OR NO THEN Haas Alarm Description: A conditional expression was found outside of an IF-THEN,WHILE, or M99 block. Check macro formatting.

Haas Alarm: 515 TOO MANY CONDITIONALS IN A BLOCK

Alarm: 515 TOO MANY CONDITIONALS IN A BLOCK Haas Alarm Description: Only one conditional expression is allowed in any WHILE or IF-THEN block. Check macro formatting

Haas Alarm: 514 ILLEGAL MACRO ADDRESS REFERENCE

Alarm: 514 ILLEGAL MACRO ADDRESS REFERENCE Haas Alarm Description: Alphabetic addresses N and O are illegal variables. You cannot declare N#1, etc. See Operator manual macro section for valid variables.

Haas Alarm: 513 VARIABLE REFERENCE NOT ALLOWED WITH N OR O

Alarm: 513 VARIABLE REFERENCE NOT ALLOWED WITH N OR O Haas Alarm Description: Alphabetic addresses N and O are illegal variables. You cannot declare N#1, etc. See Operator manual macro…