Haas Parameters
Haas lathe/mill parameters
Haas Parameter 446 W EXACT STOP DIST.
Haas Parameter 446 W EXACT STOP DIST. This parameter controls how close the axis must be to its end point when exact stop is programmed. They apply in G09 and G64.They…
Haas Parameter 469 Tt MAX SPEED
Haas Parameter 469 Tt MAX SPEED Maximum speed for this axis in steps per second.
Haas Parameter 470 Tt MAX ERROR
Haas Parameter 470 Tt MAX ERROR Maximum error allowed in servo loop before alarm is generated. Units are encoder steps. This is the maximum allowable error in Hz between commanded speed…
Haas Parameter 471 Tt FUSE LEVEL
Haas Parameter 471 Tt FUSE LEVEL Limits average power to motor. If not set correctly, this parameter can cause an “overload” alarm.
Haas Parameter 433 W MAX SPEED
Haas Parameter 433 W MAX SPEED Maximum speed for this axis in steps per second.
Haas Parameter 434 W MAX ERROR
Haas Parameter 434 W MAX ERROR Maximum error allowed in servo loop before alarm is generated. Units are encoder steps. This is the maximum allowable error in Hz between commanded speed…
Haas Parameter 435 W FUSE LEVEL
Haas Parameter 435 W FUSE LEVEL Limits average power to motor. If not set correctly, this parameter can cause an “overload” alarm.
Haas Parameter 436 W BACK EMF
Haas Parameter 436 W BACK EMF Back EMF of motor in volts per 1000 rpm times 10. Thus a 63 volt/Krpm motor gives 630.
Haas Parameter 476 Tt IN POSITION LIMIT
Haas Parameter 476 Tt IN POSITION LIMIT How close the motor must be to the endpoint before any move is considered complete when not in exact stop (G09 or G61). Units…
Haas Parameter 420 V SCALE GAIN MULT
Haas Parameter 420 V SCALE GAIN MULT Used on machines with linear scales. Linear scales are used to continuously correct any errors in encoder position. The parameter determines the gain of…
Haas Parameter 459 W SCALES PER REV
Haas Parameter 459 W SCALES PER REV Used on machines equipped with linear scales.
Haas Parameter 477 Tt MAX CURRENT
Haas Parameter 477 Tt MAX CURRENT Fuse level in % of max power to motor. Applies only when motor is stopped. Corresponds to maximum peak current provided by the amplifier. 4095…
Haas Parameter 421 V LINEAR SCREW OFFS
Haas Parameter 421 V LINEAR SCREW OFFS Used on machines with linear scales. This parameter accounts for the unused portion of the ballscrew between zero and the actual motor.
Haas Parameter 460 W SPINDLE THERM COEF.
Haas Parameter 460 W SPINDLE THERM COEF. Supports Spindle Head Thermal Compensation feature.
Haas Parameter 478 Tt D*D GAIN
Haas Parameter 478 Tt D*D GAIN Second derivative gain in servo loop.
Haas Parameter 422 V SCALES PER INCH
Haas Parameter 422 V SCALES PER INCH Used on machines equipped with linear scales.
Haas Parameter 463 Tt P GAIN
Haas Parameter 463 Tt P GAIN Proportional gain in servo loop.
Haas Parameter 481 Tt GRID OFFSET
Haas Parameter 481 Tt GRID OFFSET Shifts the effective position of the encoder Z pulse. It can correct for a motor or home switch positioning error.
Haas Parameter 482 Tt EXACT STOP DIST.
Haas Parameter 482 Tt EXACT STOP DIST. This parameter controls how close the axis must be to its end point when exact stop is programmed. They apply in G09 and G64.They…
Haas Parameter 483 Tt FRICTION COMPENSAT
Haas Parameter 483 Tt FRICTION COMPENSAT Compensate for friction on the axis. The units are in 0.004V.
Haas Parameter 484 Tt ACCEL FEED FORWARD
Haas Parameter 484 Tt ACCEL FEED FORWARD Set the feed forward gain for the axis servo. Constant value, it has no units.
Haas Parameter 485 Tt SCREW COMP. COEF.
Haas Parameter 485 Tt SCREW COMP. COEF. Coefficient of heating of the ballscrew, and is used to decrease or shorten the screw length.
Haas Parameter 486 Tt AIR BRAKE DELAY
Haas Parameter 486 Tt AIR BRAKE DELAY Delay provided for air to release from the brake prior to moving. Units are milliseconds.
Haas Parameter 511 C DEAD ZONE
Haas Parameter 511 C DEAD ZONE Dead zone correction for driver electronics. Units are 0.0000001 seconds.
Haas Parameter 492 Tt SCALE GAIN MULT
Haas Parameter 492 Tt SCALE GAIN MULT Used on machines with linear scales. Linear scales are used to continuously correct any errors in encoder position. The parameter determines the gain of…
Haas Parameter 512 C IN POSITION LIMIT
Haas Parameter 512 C IN POSITION LIMIT How close the motor must be to the endpoint before any move is considered complete when not in exact stop (G09 or G61). Units…
Haas Parameter 493 Tt LINEAR SCREW OFFS
Haas Parameter 493 Tt LINEAR SCREW OFFS Used on machines with linear scales. This parameter accounts for the unused portion of the ballscrew between zero and the actual motor.
Haas Parameter 513 C MAX CURRENT
Haas Parameter 513 C MAX CURRENT Fuse level in % of max power to motor. Applies only when motor is stopped. Corresponds to maximum peak current provided by the amplifier….
Haas Parameter 472 Tt BACK EMF
Haas Parameter 472 Tt BACK EMF Back EMF of motor in volts per 1000 rpm times 10. Thus a 63 volt/Krpm motor gives 630.
Haas Parameter 494 Tt SCALES PER INCH
Haas Parameter 494 Tt SCALES PER INCH Used on machines equipped with linear scales.
Haas Parameter 473 Tt STEPS/REVOLUTION
Haas Parameter 473 Tt STEPS/REVOLUTION Encoder steps per revolution of motor. An 8192 line encoder gives: 8192 x 4 = 32768
Haas Parameter 495 Tt SCALES PER REV
Haas Parameter 495 Tt SCALES PER REV Used on machines equipped with linear scales.
Haas Parameter 474 Tt BACKLASH
Haas Parameter 474 Tt BACKLASH Backlash correction in encoder steps.
Haas Parameter 496 Tt SPINDLE THERM COEF.
Haas Parameter 496 Tt SPINDLE THERM COEF. Supports Spindle Head Thermal Compensation feature.
Haas Parameter 475 Tt DEAD ZONE
Haas Parameter 475 Tt DEAD ZONE Dead zone correction for driver electronics. Units are 0.0000001 seconds.