Haas Parameters

Haas lathe/mill parameters

Haas Parameter 476 Tt IN POSITION LIMIT

Haas Parameter 476 Tt IN POSITION LIMIT How close the motor must be to the endpoint before any move is considered complete when not in exact stop (G09 or G61). Units…

Haas Parameter 420 V SCALE GAIN MULT

Haas Parameter 420 V SCALE GAIN MULT Used on machines with linear scales. Linear scales are used to continuously correct any errors in encoder position. The parameter determines the gain of…

Haas Parameter 459 W SCALES PER REV

Haas Parameter 459 W SCALES PER REV Used on machines equipped with linear scales.

Haas Parameter 477 Tt MAX CURRENT

Haas Parameter 477 Tt MAX CURRENT Fuse level in % of max power to motor. Applies only when motor is stopped. Corresponds to maximum peak current provided by the amplifier. 4095…

Haas Parameter 421 V LINEAR SCREW OFFS

Haas Parameter 421 V LINEAR SCREW OFFS Used on machines with linear scales. This parameter accounts for the unused portion of the ballscrew between zero and the actual motor.

Haas Parameter 460 W SPINDLE THERM COEF.

Haas Parameter 460 W SPINDLE THERM COEF. Supports Spindle Head Thermal Compensation feature.

Haas Parameter 478 Tt D*D GAIN

Haas Parameter 478 Tt D*D GAIN Second derivative gain in servo loop.

Haas Parameter 422 V SCALES PER INCH

Haas Parameter 422 V SCALES PER INCH Used on machines equipped with linear scales.

Haas Parameter 463 Tt P GAIN

Haas Parameter 463 Tt P GAIN Proportional gain in servo loop.

Haas Parameter 423 V SCALES PER REV

Haas Parameter 423 V SCALES PER REV Used on machines equipped with linear scales.

Haas Parameter 464 Tt D GAIN

Haas Parameter 464 Tt D GAIN Derivative gain in servo loop.

Haas Parameter 404 V IN POSITION LIMIT

Haas Parameter 404 V IN POSITION LIMIT How close the motor must be to the endpoint before any move is considered complete when not in exact stop (G09 or G61). Units…

Haas Parameter 443 W ACC/DEC T CONST

Haas Parameter 443 W ACC/DEC T CONST Exponential acceleration time constant. Units are 1/10000 seconds. This parameter provides for a constant ratio between profiling lag and servo velocity at the endpoint…

Haas Parameter 405 V MAX CURRENT

Haas Parameter 405 V MAX CURRENT Fuse level in % of max power to motor. Applies only when motor is stopped. Corresponds to maximum peak current provided by the amplifier. 4095…

Haas Parameter 444 W PHASE OFFSET

Haas Parameter 444 W PHASE OFFSET The motor phase offset for W motor. Constant value, the value has no units.

Haas Parameter 406 V D*D GAIN

Haas Parameter 406 V D*D GAIN Second derivative gain in servo loop.

Haas Parameter 445 W GRID OFFSET

Haas Parameter 445 W GRID OFFSET Shifts the effective position of the encoder Z pulse. It can correct for a motor or home switch positioning error.

Haas Parameter 486 Tt AIR BRAKE DELAY

Haas Parameter 486 Tt AIR BRAKE DELAY Delay provided for air to release from the brake prior to moving. Units are milliseconds.

Haas Parameter 511 C DEAD ZONE

Haas Parameter 511 C DEAD ZONE Dead zone correction for driver electronics. Units are 0.0000001 seconds.

Haas Parameter 492 Tt SCALE GAIN MULT

Haas Parameter 492 Tt SCALE GAIN MULT Used on machines with linear scales. Linear scales are used to continuously correct any errors in encoder position. The parameter determines the gain of…

Haas Parameter 512 C IN POSITION LIMIT

Haas Parameter 512 C IN POSITION LIMIT How close the motor must be to the endpoint before any move is considered complete when not in exact stop (G09 or G61). Units…

Haas Parameter 493 Tt LINEAR SCREW OFFS

Haas Parameter 493 Tt LINEAR SCREW OFFS Used on machines with linear scales. This parameter accounts for the unused portion of the ballscrew between zero and the actual motor.

Haas Parameter 513 C MAX CURRENT

Haas Parameter 513 C MAX CURRENT Fuse level in % of max power to motor. Applies only when motor is stopped. Corresponds to maximum peak current provided by the amplifier….

Haas Parameter 472 Tt BACK EMF

Haas Parameter 472 Tt BACK EMF Back EMF of motor in volts per 1000 rpm times 10. Thus a 63 volt/Krpm motor gives 630.

Haas Parameter 494 Tt SCALES PER INCH

Haas Parameter 494 Tt SCALES PER INCH Used on machines equipped with linear scales.

Haas Parameter 473 Tt STEPS/REVOLUTION

Haas Parameter 473 Tt STEPS/REVOLUTION Encoder steps per revolution of motor. An 8192 line encoder gives: 8192 x 4 = 32768

Haas Parameter 495 Tt SCALES PER REV

Haas Parameter 495 Tt SCALES PER REV Used on machines equipped with linear scales.

Haas Parameter 474 Tt BACKLASH

Haas Parameter 474 Tt BACKLASH Backlash correction in encoder steps.

Haas Parameter 496 Tt SPINDLE THERM COEF.

Haas Parameter 496 Tt SPINDLE THERM COEF. Supports Spindle Head Thermal Compensation feature.

Haas Parameter 475 Tt DEAD ZONE

Haas Parameter 475 Tt DEAD ZONE Dead zone correction for driver electronics. Units are 0.0000001 seconds.

Haas Parameter 497 Tt SPINDLE THERM T.C.

Haas Parameter 497 Tt SPINDLE THERM T.C. Not Used.

Haas Parameter 499 C P GAIN

Haas Parameter 499 C P GAIN Proportional gain in servo loop.

Haas Parameter 500 C D GAIN

Haas Parameter 500 C D GAIN Derivative gain in servo loop.

Haas Parameter 501 C I GAIN

Haas Parameter 501 C I GAIN Integral gain in servo loop.

Haas Parameter 480 Tt PHASE OFFSET

Haas Parameter 480 Tt PHASE OFFSET The motor phase offset for Tt motor. Constant value, the value has no units.