Haas Parameters

Haas lathe/mill parameters

Haas Parameter 478 Tt D*D GAIN

Haas Parameter 478 Tt D*D GAIN Second derivative gain in servo loop.

Haas Parameter 422 V SCALES PER INCH

Haas Parameter 422 V SCALES PER INCH Used on machines equipped with linear scales.

Haas Parameter 463 Tt P GAIN

Haas Parameter 463 Tt P GAIN Proportional gain in servo loop.

Haas Parameter 423 V SCALES PER REV

Haas Parameter 423 V SCALES PER REV Used on machines equipped with linear scales.

Haas Parameter 464 Tt D GAIN

Haas Parameter 464 Tt D GAIN Derivative gain in servo loop.

Haas Parameter 404 V IN POSITION LIMIT

Haas Parameter 404 V IN POSITION LIMIT How close the motor must be to the endpoint before any move is considered complete when not in exact stop (G09 or G61). Units…

Haas Parameter 443 W ACC/DEC T CONST

Haas Parameter 443 W ACC/DEC T CONST Exponential acceleration time constant. Units are 1/10000 seconds. This parameter provides for a constant ratio between profiling lag and servo velocity at the endpoint…

Haas Parameter 405 V MAX CURRENT

Haas Parameter 405 V MAX CURRENT Fuse level in % of max power to motor. Applies only when motor is stopped. Corresponds to maximum peak current provided by the amplifier. 4095…

Haas Parameter 444 W PHASE OFFSET

Haas Parameter 444 W PHASE OFFSET The motor phase offset for W motor. Constant value, the value has no units.

Haas Parameter 406 V D*D GAIN

Haas Parameter 406 V D*D GAIN Second derivative gain in servo loop.

Haas Parameter 445 W GRID OFFSET

Haas Parameter 445 W GRID OFFSET Shifts the effective position of the encoder Z pulse. It can correct for a motor or home switch positioning error.

Haas Parameter 407 V ACC/DEC T CONST

Haas Parameter 407 V ACC/DEC T CONST Exponential acceleration time constant. Units are 1/10000 seconds. This parameter provides for a constant ratio between profiling lag and servo velocity at the endpoint…

Haas Parameter 446 W EXACT STOP DIST.

Haas Parameter 446 W EXACT STOP DIST. This parameter controls how close the axis must be to its end point when exact stop is programmed. They apply in G09 and G64.They…

Haas Parameter 469 Tt MAX SPEED

Haas Parameter 469 Tt MAX SPEED Maximum speed for this axis in steps per second.

Haas Parameter 470 Tt MAX ERROR

Haas Parameter 470 Tt MAX ERROR Maximum error allowed in servo loop before alarm is generated. Units are encoder steps. This is the maximum allowable error in Hz between commanded speed…

Haas Parameter 471 Tt FUSE LEVEL

Haas Parameter 471 Tt FUSE LEVEL Limits average power to motor. If not set correctly, this parameter can cause an “overload” alarm.

Haas Parameter 433 W MAX SPEED

Haas Parameter 433 W MAX SPEED Maximum speed for this axis in steps per second.

Haas Parameter 473 Tt STEPS/REVOLUTION

Haas Parameter 473 Tt STEPS/REVOLUTION Encoder steps per revolution of motor. An 8192 line encoder gives: 8192 x 4 = 32768

Haas Parameter 495 Tt SCALES PER REV

Haas Parameter 495 Tt SCALES PER REV Used on machines equipped with linear scales.

Haas Parameter 474 Tt BACKLASH

Haas Parameter 474 Tt BACKLASH Backlash correction in encoder steps.

Haas Parameter 496 Tt SPINDLE THERM COEF.

Haas Parameter 496 Tt SPINDLE THERM COEF. Supports Spindle Head Thermal Compensation feature.

Haas Parameter 475 Tt DEAD ZONE

Haas Parameter 475 Tt DEAD ZONE Dead zone correction for driver electronics. Units are 0.0000001 seconds.

Haas Parameter 497 Tt SPINDLE THERM T.C.

Haas Parameter 497 Tt SPINDLE THERM T.C. Not Used.

Haas Parameter 499 C P GAIN

Haas Parameter 499 C P GAIN Proportional gain in servo loop.

Haas Parameter 500 C D GAIN

Haas Parameter 500 C D GAIN Derivative gain in servo loop.

Haas Parameter 501 C I GAIN

Haas Parameter 501 C I GAIN Integral gain in servo loop.

Haas Parameter 480 Tt PHASE OFFSET

Haas Parameter 480 Tt PHASE OFFSET The motor phase offset for Tt motor. Constant value, the value has no units.

Haas Parameter 481 Tt GRID OFFSET

Haas Parameter 481 Tt GRID OFFSET Shifts the effective position of the encoder Z pulse. It can correct for a motor or home switch positioning error.

Haas Parameter 482 Tt EXACT STOP DIST.

Haas Parameter 482 Tt EXACT STOP DIST. This parameter controls how close the axis must be to its end point when exact stop is programmed. They apply in G09 and G64.They…

Haas Parameter 483 Tt FRICTION COMPENSAT

Haas Parameter 483 Tt FRICTION COMPENSAT Compensate for friction on the axis. The units are in 0.004V.

Haas Parameter 484 Tt ACCEL FEED FORWARD

Haas Parameter 484 Tt ACCEL FEED FORWARD Set the feed forward gain for the axis servo. Constant value, it has no units.

Haas Parameter 485 Tt SCREW COMP. COEF.

Haas Parameter 485 Tt SCREW COMP. COEF. Coefficient of heating of the ballscrew, and is used to decrease or shorten the screw length.

Haas Parameter 486 Tt AIR BRAKE DELAY

Haas Parameter 486 Tt AIR BRAKE DELAY Delay provided for air to release from the brake prior to moving. Units are milliseconds.

Haas Parameter 511 C DEAD ZONE

Haas Parameter 511 C DEAD ZONE Dead zone correction for driver electronics. Units are 0.0000001 seconds.

Haas Parameter 492 Tt SCALE GAIN MULT

Haas Parameter 492 Tt SCALE GAIN MULT Used on machines with linear scales. Linear scales are used to continuously correct any errors in encoder position. The parameter determines the gain of…