Haas Parameters

Haas lathe/mill parameters

Haas Parameter 572 C AXIS ENG TIMEOUT – Haas Lathe

Haas Parameter 572 C AXIS ENG TIMEOUT – Haas Lathe Specifies the C-axis timeout value for seeing the engaged switch on engagement or the disengaged switch on disengage. The units are…

Haas Parameter 550 Ss MAG CURRENT

Haas Parameter 550 Ss MAG CURRENT Magnetization component of the current in the motor, also called the flux or field current.

Haas Parameter 551 Ss SPIN ORIENT MARGIN

Haas Parameter 551 Ss SPIN ORIENT MARGIN When a spindle orientation is done, if the actual position of the spindle is within this value (plus or minus), the spindle will be…

Haas Parameter 552 Ss SPINDLE STOP FREQ

Haas Parameter 552 Ss SPINDLE STOP FREQ Spindle considered stopped (discrete input SP ST*=0) when speed drops below this value. Units are encoder steps/millisecond.

Haas Parameter 553 Ss START/STOP DELAY

Haas Parameter 553 Ss START/STOP DELAY This delay is used at the start of motion to magnetize the rotor before acceleration starts. When the motor comes to a stop it remains…

Haas Parameter 538 Ss SLIP GAIN

Haas Parameter 538 Ss SLIP GAIN Calculated slip rate depends on two other variables: speed and current. Slip rate = slip gain x (speed/max speed) x (current/max current). The slip gain…

Haas Parameter 555 Ss SWITCH FREQUENCY

Haas Parameter 555 Ss SWITCH FREQUENCY Frequency at which the spindle motor windings are switched. Note that there is a hysteresis band around this point, defined by Parameter 198.

Haas Parameter 539 Ss MIN SLIP

Haas Parameter 539 Ss MIN SLIP Minimum value allowed from the slip rate. From the equation: Slip rate = slip gain x (speed/max speed) x (current/max current). It can be…

Haas Parameter 557 Ss PRE-SWITCH DELAY

Haas Parameter 557 Ss PRE-SWITCH DELAY Amount of time allowed for the motor current to drop before winding change contactors are switched.

Haas Parameter 558 Ss POST-SWITCH DELAY

Haas Parameter 558 Ss POST-SWITCH DELAY Amount of time allowed for contactors to stabilize after switch is commanded, before current is applied to motor.

Haas Parameter 581 APL FLIPPER SETTLE – Haas Lathe

Haas Parameter 581 APL FLIPPER SETTLE – Haas Lathe Supports the Haas Lathe APL. It specifies the rotational time for the gripper after the switch is encountered and should be set…

Haas Parameter 559 Ss D:Y CURRENT RATIO

Haas Parameter 559 Ss D:Y CURRENT RATIO Defines the ratio between the two winding configurations. The default winding is Y, and the parameters are set for the Y winding. Used to…

Haas Parameter 582 APL FLIPPER TIME OT – Haas Lathe

Haas Parameter 582 APL FLIPPER TIME OT – Haas Lathe Supports the Haas Lathe APL. Units are milliseconds.

Haas Parameter 560 Ss BELT COMPENSATION

Haas Parameter 560 Ss BELT COMPENSATION Belt Compensation

Haas Parameter 583 APL MAX POSITIONS – Haas Lathe

Haas Parameter 583 APL MAX POSITIONS – Haas Lathe Supports the Haas Lathe APL. It specifies the number of switch positions in rotation.

Haas Parameter 563 Ss Reserved

Haas Parameter 563 Ss Reserved Reserved.

Haas Parameter 569 Ss SPINDLE THERM T.C.

Haas Parameter 569 Ss SPINDLE THERM T.C. Supports Spindle Head Thermal Compensation feature.

Haas Parameter 570 SUBSPIN ENC ST/REV – Haas Lathe

Haas Parameter 570 SUBSPIN ENC ST/REV – Haas Lathe Sets the number of encoder steps per revolution of the subspindle encoder.

Haas Parameter 571 SUBSPINDLE ST/REV – Haas Lathe

Haas Parameter 571 SUBSPINDLE ST/REV – Haas Lathe Sets the number of encoder steps per revolution of the subspindle. It only applies to the subspindle rigid tapping option.

Haas Parameter 573 C AXIS ENG DELAY 1 – Haas Lathe

Haas Parameter 573 C AXIS ENG DELAY 1 – Haas Lathe Specifies C-axis delay after spindle orientation and before engagement. Its purpose is to let the spindle orientation settle. The units…

Haas Parameter 574 C AXIS ENG DELAY 2 – Haas Lathe

Haas Parameter 574 C AXIS ENG DELAY 2 – Haas Lathe Specifies the C-axis delay after engagement before the motion completes. Its purpose is to allow the C-axis engagement to come…

Haas Parameter 575 THRD PTCH FACT PPM – Haas Lathe

Haas Parameter 575 THRD PTCH FACT PPM – Haas Lathe Allows the customer to factor feedrate on G32, G76 and G92 threading as necessary for particular applications.The units are ppm (parts…

Haas Parameter 576 MAX SS RPM LOW GEAR – Haas Lathe

Haas Parameter 576 MAX SS RPM LOW GEAR – Haas Lathe Max subspindle rpm in low gear. This is maximum rpm available to subspindle. When this speed is programmed, the D-to-A…

Haas Parameter 554 Ss ACCEL LIMIT LOAD

Haas Parameter 554 Ss ACCEL LIMIT LOAD Used when a Vector Drive is installed. It is % load limit during acceleration. If load reaches this limit, control slows down acceleration. If…

Haas Parameter 577 SS ORIENT OFFSET – Haas Lathe

Haas Parameter 577 SS ORIENT OFFSET – Haas Lathe Subspindle Orientation Offset. It is used to orient the subspindle properly anytime it needs to be locked, such as prior to a…

Haas Parameter 578 SS HIGH GR MIN SPD – Haas Lathe

Haas Parameter 578 SS HIGH GR MIN SPD – Haas Lathe Command speed used to rotate subspindle motor when orienting subspindle in high gear. Units are maximum subspindle rpm divided by…

Haas Parameter 556 Ss SWITCH HYSTERESIS

Haas Parameter 556 Ss SWITCH HYSTERESIS Defines the + hysteresis band around Parameter 197. For example, if Parameter 197 is 85 Hz, and Parameter 198 is 5 Hz, the switching will…

Haas Parameter 579 SS LOW GR MIN SPD – Haas Lathe

Haas Parameter 579 SS LOW GR MIN SPD – Haas Lathe Command speed used to rotate subspindle motor when orienting subspindle in low gear. Units are maximum subspindle rpm divided by…

Haas Parameter 580 TS HYD RETRACT TIME – Haas Lathe

Haas Parameter 580 TS HYD RETRACT TIME – Haas Lathe Added for the SL-10 hydraulic no-encoder tailstock. It specifies the amount of time (in ms) that the tailstock center will be…

Haas Parameter 601 TOOL CHANGE DELAY – Haas Mill

Haas Parameter 601 TOOL CHANGE DELAY – Haas Mill On a mill where the operator must be warned that a running program doing a tool change (no enclosure) it beeps and…

Haas Parameter 603 COOLANT LEVEL MIN

Haas Parameter 603 COOLANT LEVEL MIN Coolant Level Sensor minimum level. Used to calibrate the bar graph.

Haas Parameter 604 COOLANT LEVEL MAX

Haas Parameter 604 COOLANT LEVEL MAX Coolant Level Sensor maximum level. Used to calibrate the bar graph.

Haas Parameter 605 PALLET CHANGER TYPE – Haas Mill

Haas Parameter 605 PALLET CHANGER TYPE – Haas Mill Defines the type of pallet changer on the machine. Also see Parameter 606

Haas Parameter 584 APL GRIP OPEN TIME – Haas Lathe

Haas Parameter 584 APL GRIP OPEN TIME – Haas Lathe Supports Haas Lathe APL. It specifies maximum allowable time for opening the gripper. Units are milliseconds.

Haas Parameter 611 BAR FEEDER TYPE – Haas Lathe

Haas Parameter 611 BAR FEEDER TYPE – Haas Lathe Supports the Bar 100 Air-Driven bar feeder. It should be set to 2 on all lathes fitted with the Bar 100,…