Haas Parameters

Haas lathe/mill parameters

Haas Parameter 675 V INDEXER DOWN SETTLE

Haas Parameter 675 V INDEXER DOWN SETTLE See parameter 668

Haas Parameter 659 A INDEXER DWN TIMEOUT

Haas Parameter 659 A INDEXER DWN TIMEOUT See parameter 656

Haas Parameter 676 W INDEXER DOWN SETTLE

Haas Parameter 676 W INDEXER DOWN SETTLE See parameter 668

Haas Parameter 660 B INDEXER DWN TIMEOUT

Haas Parameter 660 B INDEXER DWN TIMEOUT See parameter 656

Haas Parameter 677 SP INDEXER DOWN SETTLE

Haas Parameter 677 SP INDEXER DOWN SETTLE See parameter 668

Haas Parameter 661 C INDEXER DWN TIMEOUT

Haas Parameter 661 C INDEXER DWN TIMEOUT See parameter 656

Haas Parameter 678 Tt INDEXER DOWN SETTLE

Haas Parameter 678 Tt INDEXER DOWN SETTLE See parameter 668

Haas Parameter 662 U INDEXER DWN TIMEOUT

Haas Parameter 662 U INDEXER DWN TIMEOUT See parameter 656

Haas Parameter 647 A INDEXER INCREMENTt

Haas Parameter 647 A INDEXER INCREMENTt See Parameter 644.

Haas Parameter 663 V INDEXER DWN TIMEOUT

Haas Parameter 663 V INDEXER DWN TIMEOUT See parameter 656

Haas Parameter 680 X LEAD COMPENS SHIFT

Haas Parameter 680 X LEAD COMPENS SHIFT Lead screw compensation shift factor. Shift factor when applying lead screw compensation. Lead screw compensation is based on a table of 512 offsets; each…

Haas Parameter 698 MOM PURGE OFF TIME – Haas Mill

Haas Parameter 698 MOM PURGE OFF TIME – Haas Mill Sets pump off time.

Haas Parameter 681 Y LEAD COMPENS SHIFT

Haas Parameter 681 Y LEAD COMPENS SHIFT Lead screw compensation shift factor. Shift factor when applying lead screw compensation. Lead screw compensation is based on a table of 512 offsets; each…

Haas Parameter 699 MOM POWER UP PURGE – Haas Mill

Haas Parameter 699 MOM POWER UP PURGE – Haas Mill Sets number of purge cycles on power-up restart.

Haas Parameter 682 Z LEAD COMPENS SHIFT

Haas Parameter 682 Z LEAD COMPENS SHIFT Lead screw compensation shift factor. Shift factor when applying lead screw compensation. Lead screw compensation is based on a table of 512 offsets; each…

Haas Parameter 700 Y-AXIS WEDGE ANGLE – Haas Lathe

Haas Parameter 700 Y-AXIS WEDGE ANGLE – Haas Lathe The physical angle between the X axis at the bottom of a wedge structure and another axis mounted on the top side…

Haas Parameter 683 A LEAD COMPENS SHIFT

Haas Parameter 683 A LEAD COMPENS SHIFT Lead screw compensation shift factor. Shift factor when applying lead screw compensation. Lead screw compensation is based on a table of 512 offsets; each…

Haas Parameter 702 SHUTTLE MIN TIME IN

Haas Parameter 702 SHUTTLE MIN TIME IN Minimum time for the shuttle to reach the In position.

Haas Parameter 704 SMTC2 UNCLAMP POS

Haas Parameter 704 SMTC2 UNCLAMP POS Supports the high speed tool changer. It specifies the absolute position in degrees *1000 which the TT axis will stop at in order to unclamp…

Haas Parameter 670 Z INDEXER DOWN SETTLE

Haas Parameter 670 Z INDEXER DOWN SETTLE See parameter 668

Haas Parameter 671 A INDEXER DOWN SETTLE

Haas Parameter 671 A INDEXER DOWN SETTLE See parameter 668

Haas Parameter 672 B INDEXER DOWN SETTLE

Haas Parameter 672 B INDEXER DOWN SETTLE See parameter 668

Haas Parameter 673 C INDEXER DOWN SETTLE

Haas Parameter 673 C INDEXER DOWN SETTLE See parameter 668

Haas Parameter 689 Sp LEAD COMPENS SHIFT

Haas Parameter 689 Sp LEAD COMPENS SHIFT Lead screw compensation shift factor. Shift factor when applying lead screw compensation. Lead screw compensation is based on a table of 512 offsets; each…

Haas Parameter 690 Tt LEAD COMPENS SHIFT

Haas Parameter 690 Tt LEAD COMPENS SHIFT Lead screw compensation shift factor. Shift factor when applying lead screw compensation. Lead screw compensation is based on a table of 512 offsets; each…

Haas Parameter 711 POCKET UP SETTLE – Haas Mill

Haas Parameter 711 POCKET UP SETTLE – Haas Mill Supports a vertical mill side-mount tool changer. It specifies the amount of time, in 50ths of a second, a carousel is to…

Haas Parameter 691 Ss LEAD COMPENS SHIFT

Haas Parameter 691 Ss LEAD COMPENS SHIFT Lead screw compensation shift factor. Shift factor when applying lead screw compensation. Lead screw compensation is based on a table of 512 offsets; each…

Haas Parameter 712 VD/MINI P.S. TYPE

Haas Parameter 712 VD/MINI P.S. TYPE This parameter specifies the Vector Drive or Mini Power supply type.

Haas Parameter 692 STEADY REST OUTPUT – Haas Lathe

Haas Parameter 692 STEADY REST OUTPUT – Haas Lathe Supports the steady rest option. If a lathe has the option, it must be set to the output relay number that…

Haas Parameter 713 CHAMFER SWITCH ANGLE

Haas Parameter 713 CHAMFER SWITCH ANGLE Specifies the angle at which to switch the master/slave axis in chamfer jog mode on a TL1. Units: Degrees X 1000.

Haas Parameter 679 Ss INDEXER DOWN SETTLE

Haas Parameter 679 Ss INDEXER DOWN SETTLE See parameter 668

Haas Parameter 741 PALLET POOL LINEAR AXIS

Haas Parameter 741 PALLET POOL LINEAR AXIS Specifies the servo axis number controlling the pallet pool’s slider axis. A=3, B=4, U=7, W=8 etc.

Haas Parameter 721 ‘RUNNING’ RELAY

Haas Parameter 721 ‘RUNNING’ RELAY Supports the Machine Data Collection feature which specifies output relay to be turned on when machine is in Running mode. This only works when set to…

Haas Parameter 722 TOOL CLEAN 2 ON – Haas Mill

Haas Parameter 722 TOOL CLEAN 2 ON – Haas Mill Tool arm angle to start air blast. Units are degrees x 1000.

Haas Parameter 723 TOOL CLEAN 2 OFF – Haas Mill

Haas Parameter 723 TOOL CLEAN 2 OFF – Haas Mill Tool arm angle to start air blast. Units are degrees x 1000.