Haas Parameters

Haas lathe/mill parameters

Haas Parameter 706 TC UNCLAMP POST POS

Haas Parameter 706 TC UNCLAMP POST POS For tool changers with one-motion tool change (type 11 per parameter 710) this parameter defines the position of the tool arm, in degrees times…

Haas Parameter 727 APC CHAIN MIN TIME – Haas Mill

Haas Parameter 727 APC CHAIN MIN TIME – Haas Mill Defines the time to wait before some switch fault checks are to begin. It should be set to 3000 on…

Haas Parameter 707 TC CLAMP POST POS

Haas Parameter 707 TC CLAMP POST POS For tool changers with one-motion tool change (type 11 per parameter 710) this parameter defines the position of the tool arm, in degrees times…

Haas Parameter 728 Peak Sub SP PWR KW – Haas Lathe

Haas Parameter 728 Peak Sub SP PWR KW – Haas Lathe Used to calculate subspindle load, which is displayed as SS LOAD on the Current Commands screen.

Haas Parameter 708 PALLET CHANGER AXIS

Haas Parameter 708 PALLET CHANGER AXIS Specifies the MOCON channel of the MDC-1 and EC-300 pallet changer. It enables both the servo axis pallet changer and the Super SMTC tool changer…

Haas Parameter 731 PWR FAULT MAX TIME

Haas Parameter 731 PWR FAULT MAX TIME Parameters 730 and 731 support the optional Power Failure Detect Module. Parameter 730, Pwr Fault Threshold units are an analog to digital value. Parameter…

Haas Parameter 709 SMTC DR OUTPUT RELY

Haas Parameter 709 SMTC DR OUTPUT RELY Output relay that should be activated for the tool changer door. Set to 39 for the EC-300. Set to 1 for the EC-400. Set…

Haas Parameter 732 IPS PROBE – Haas Mill

Haas Parameter 732 IPS PROBE – Haas Mill The operator can use the intuitive probe screens, on a Tool Room mill, with the IPS feature activated, a probe, and this parameter…

Haas Parameter 693 STEADY REST INPUT – Haas Lathe

Haas Parameter 693 STEADY REST INPUT – Haas Lathe Supports the steady rest option. If a lathe has the option and a foot pedal for the steady rest, it must…

Haas Parameter 716 COLOR CMD POSITION

Haas Parameter 716 COLOR CMD POSITION Changes the color of the positions text displayed on the Current Commands page on an LCD monitor. See color values listed for Parameter 715.

Haas Parameter 738 FIXTURE CLAMP INPUT

Haas Parameter 738 FIXTURE CLAMP INPUT Can be set to discrete input value specifying user’s fixture sensor. Zero deactivates feature. If fixture is unclamped, running the spindle will generate alarm 973…

Haas Parameter 696 MOM TYPE – Haas Mill

Haas Parameter 696 MOM TYPE – Haas Mill Turns the MOM option ON.

Haas Parameter 717 COLOR CMD G-CODE

Haas Parameter 717 COLOR CMD G-CODE Changes the color of the active G and M code text displayed on the Current Commands page on an LCD monitor See color values listed…

Haas Parameter 739 TOOL TURRET OFFSET

Haas Parameter 739 TOOL TURRET OFFSET Turret position offset value for turret types 2 and 3. The default value for turret type 2 (4-position turret) is 0. The default value for…

Haas Parameter 697 MOM PURGE SIZE (MS) – Haas Mill

Haas Parameter 697 MOM PURGE SIZE (MS) – Haas Mill Sets pump ON time (in milliseconds).

Haas Parameter 740 PALLET POOL PALLETS

Haas Parameter 740 PALLET POOL PALLETS Specifies the number of pallets in the pallet pool system. Distinct from Parameter 606, which defines the number of pallets in the machine’s built-in rotary…

Haas Parameter 741 PALLET POOL LINEAR AXIS

Haas Parameter 741 PALLET POOL LINEAR AXIS Specifies the servo axis number controlling the pallet pool’s slider axis. A=3, B=4, U=7, W=8 etc.

Haas Parameter 721 ‘RUNNING’ RELAY

Haas Parameter 721 ‘RUNNING’ RELAY Supports the Machine Data Collection feature which specifies output relay to be turned on when machine is in Running mode. This only works when set to…

Haas Parameter 744 COLOR RUNPROG 1

Haas Parameter 744 COLOR RUNPROG 1 This controls the colors of highlighted text, executed blocks, and remaining blocks in a G-Code program when it is running or in feed hold….

Haas Parameter 745 COLOR RUNPROG 2

Haas Parameter 745 COLOR RUNPROG 2 See Parameter 744

Haas Parameter 746 COLOR RUNPROG 3

Haas Parameter 746 COLOR RUNPROG 3 See Parameter 744

Haas Parameter 813 AXIS PRESSURE TIME

Haas Parameter 813 AXIS PRESSURE TIME Specifies the minimum stable high pressure detection time in milliseconds during axis lubricant discharge. The control will display the LOW LUBE message if the system…

Haas Parameter 747 PALLET POOL LIFT DOWN DWELL

Haas Parameter 747 PALLET POOL LIFT DOWN DWELL Specifies the dwell time, in milliseconds, to wait after the switch indicates that the lift is down before “down” is assumed.

Haas Parameter 814 AXIS PRESSURE TIMEOUT

Haas Parameter 814 AXIS PRESSURE TIMEOUT Specifies the duration in milliseconds after the start of the axis lubrication cycle, during which high pressure is expected to occur. If pressure is not…

Haas Parameter 748 PALLET POOL LIFT UP DWELL

Haas Parameter 748 PALLET POOL LIFT UP DWELL Specifies the dwell time, in milliseconds, to wait after the switch indicates that the lift is up before “up” is assumed.

Haas Parameter 749 FEED ACCEL ROUGH – Haas Mill

Haas Parameter 749 FEED ACCEL ROUGH – Haas Mill Applied when Rough smoothness is selected. See the definition for parameter 302.

Haas Parameter 750 FEED T CONST ROUGH – Haas Mill

Haas Parameter 750 FEED T CONST ROUGH – Haas Mill Applied when Rough smoothness is selected. See the definition for parameter 303.

Haas Parameter 733 APC AIR BLAST RELAY – Haas Mill

Haas Parameter 733 APC AIR BLAST RELAY – Haas Mill Defines output relay that turns on the air blast on the EC-300 and MDC-500. Set to 39 for the Mill…

Haas Parameter 751 FEED DELTA V ROUGH – Haas Mill

Haas Parameter 751 FEED DELTA V ROUGH – Haas Mill Applied when Rough smoothness is selected.

Haas Parameter 735 HV ENABLE OUTPUT

Haas Parameter 735 HV ENABLE OUTPUT Controls which output is used to enable the HV power supply.

Haas Parameter 752 FEED ACCEL FINISH – Haas Mill

Haas Parameter 752 FEED ACCEL FINISH – Haas Mill Applied when Finish smoothness is selected. See the definition for parameter 302.

Haas Parameter 736 SPINDLE TYPE

Haas Parameter 736 SPINDLE TYPE Supports Office Mill (OM) and Office Lathe (OL) NSK spindle. On all OM models, this parameter must be set to 2. On all other mills, it…

Haas Parameter 753 FEED T CONST FINISH – Haas Mill

Haas Parameter 753 FEED T CONST FINISH – Haas Mill Applied when Finish smoothness is selected. See the definition for parameter 303.

Haas Parameter 804 TC CAROUSEL AXIS – Haas Mill

Haas Parameter 804 TC CAROUSEL AXIS – Haas Mill This parameter supports the Servo Side Mount Tool Changer. It should be set to 6 for the servo tool carousel to specify…

Haas Parameter 754 FEED DELTA V FINISH

Haas Parameter 754 FEED DELTA V FINISH Applied when Finish smoothness is selected. See the definition for parameter 314.