Haas Parameters
Haas lathe/mill parameters
Haas Parameter 717 COLOR CMD G-CODE
Haas Parameter 717 COLOR CMD G-CODE Changes the color of the active G and M code text displayed on the Current Commands page on an LCD monitor See color values listed…
Haas Parameter 739 TOOL TURRET OFFSET
Haas Parameter 739 TOOL TURRET OFFSET Turret position offset value for turret types 2 and 3. The default value for turret type 2 (4-position turret) is 0. The default value for…
Haas Parameter 697 MOM PURGE SIZE (MS) – Haas Mill
Haas Parameter 697 MOM PURGE SIZE (MS) – Haas Mill Sets pump ON time (in milliseconds).
Haas Parameter 740 PALLET POOL PALLETS
Haas Parameter 740 PALLET POOL PALLETS Specifies the number of pallets in the pallet pool system. Distinct from Parameter 606, which defines the number of pallets in the machine’s built-in rotary…
Haas Parameter 741 PALLET POOL LINEAR AXIS
Haas Parameter 741 PALLET POOL LINEAR AXIS Specifies the servo axis number controlling the pallet pool’s slider axis. A=3, B=4, U=7, W=8 etc.
Haas Parameter 721 ‘RUNNING’ RELAY
Haas Parameter 721 ‘RUNNING’ RELAY Supports the Machine Data Collection feature which specifies output relay to be turned on when machine is in Running mode. This only works when set to…
Haas Parameter 722 TOOL CLEAN 2 ON – Haas Mill
Haas Parameter 722 TOOL CLEAN 2 ON – Haas Mill Tool arm angle to start air blast. Units are degrees x 1000.
Haas Parameter 723 TOOL CLEAN 2 OFF – Haas Mill
Haas Parameter 723 TOOL CLEAN 2 OFF – Haas Mill Tool arm angle to start air blast. Units are degrees x 1000.
Haas Parameter 705 SMTC2 CLAMP POS
Haas Parameter 705 SMTC2 CLAMP POS Supports the high speed tool changer. It specifies the absolute position in degrees *1000 which the TT axis will stop at in order to clamp…
Haas Parameter 726 SERVO DR SAFE CURNT
Haas Parameter 726 SERVO DR SAFE CURNT The maximum current allowed when door has reached safe region specified by parameter 827 SERVO DR SAFE ZONE before coming to the closed position….
Haas Parameter 706 TC UNCLAMP POST POS
Haas Parameter 706 TC UNCLAMP POST POS For tool changers with one-motion tool change (type 11 per parameter 710) this parameter defines the position of the tool arm, in degrees times…
Haas Parameter 727 APC CHAIN MIN TIME – Haas Mill
Haas Parameter 727 APC CHAIN MIN TIME – Haas Mill Defines the time to wait before some switch fault checks are to begin. It should be set to 3000 on…
Haas Parameter 707 TC CLAMP POST POS
Haas Parameter 707 TC CLAMP POST POS For tool changers with one-motion tool change (type 11 per parameter 710) this parameter defines the position of the tool arm, in degrees times…
Haas Parameter 728 Peak Sub SP PWR KW – Haas Lathe
Haas Parameter 728 Peak Sub SP PWR KW – Haas Lathe Used to calculate subspindle load, which is displayed as SS LOAD on the Current Commands screen.
Haas Parameter 708 PALLET CHANGER AXIS
Haas Parameter 708 PALLET CHANGER AXIS Specifies the MOCON channel of the MDC-1 and EC-300 pallet changer. It enables both the servo axis pallet changer and the Super SMTC tool changer…
Haas Parameter 731 PWR FAULT MAX TIME
Haas Parameter 731 PWR FAULT MAX TIME Parameters 730 and 731 support the optional Power Failure Detect Module. Parameter 730, Pwr Fault Threshold units are an analog to digital value. Parameter…
Haas Parameter 709 SMTC DR OUTPUT RELY
Haas Parameter 709 SMTC DR OUTPUT RELY Output relay that should be activated for the tool changer door. Set to 39 for the EC-300. Set to 1 for the EC-400. Set…
Haas Parameter 732 IPS PROBE – Haas Mill
Haas Parameter 732 IPS PROBE – Haas Mill The operator can use the intuitive probe screens, on a Tool Room mill, with the IPS feature activated, a probe, and this parameter…
Haas Parameter 754 FEED DELTA V FINISH
Haas Parameter 754 FEED DELTA V FINISH Applied when Finish smoothness is selected. See the definition for parameter 314.
Haas Parameter 805 PROBE ARM TYPE
Haas Parameter 805 PROBE ARM TYPE Replaces lathe parameter 278 bit 10, TL SET PROBE. Value specifies the probe arm type: 0 = no probe arm, 1 = manual probe arm,…
Haas Parameter 718 COLOR CMD AXES LOAD
Haas Parameter 718 COLOR CMD AXES LOAD Changes the color of the axis load text displayed on the Current Commands page on an LCD monitor. See color values listed for Parameter…
Haas Parameter 719 COLOR CMD BOLD TEXT
Haas Parameter 719 COLOR CMD BOLD TEXT Changes the color of the large feed and speed text displayed on the Current Commands page on an LCD monitor. See color values listed…
Haas Parameter 757 HYDRAULIC TAILSTOCK POSITION TOLERANCE
Haas Parameter 757 HYDRAULIC TAILSTOCK POSITION TOLERANCE Specifies the hydraulic tailstock encoder zero position tolerance. Units are 10 thousandths of an inch.
Haas Parameter 720 COLOR OVERRIDE
Haas Parameter 720 COLOR OVERRIDE Changes the color of the spindle and axis override text displayed on the Current Commands page on an LCD monitor. See color values listed for Parameter…
Haas Parameter 742 PALLET POOL ROTARY AXIS
Haas Parameter 742 PALLET POOL ROTARY AXIS Specifies the servo axis number controlling the pallet pool’s rotary axis. A=3, B=4, U=7, W=8, etc.
Haas Parameter 743 PALLET POOL VERTICAL AXIS
Haas Parameter 743 PALLET POOL VERTICAL AXIS Specifies the servo axis number controlling the pallet pool’s vertical (linear) axis. A=3, B=4, U=7, W=8 etc.
Haas Parameter 744 COLOR RUNPROG 1
Haas Parameter 744 COLOR RUNPROG 1 This controls the colors of highlighted text, executed blocks, and remaining blocks in a G-Code program when it is running or in feed hold….
Haas Parameter 745 COLOR RUNPROG 2
Haas Parameter 745 COLOR RUNPROG 2 See Parameter 744
Haas Parameter 746 COLOR RUNPROG 3
Haas Parameter 746 COLOR RUNPROG 3 See Parameter 744
Haas Parameter 813 AXIS PRESSURE TIME
Haas Parameter 813 AXIS PRESSURE TIME Specifies the minimum stable high pressure detection time in milliseconds during axis lubricant discharge. The control will display the LOW LUBE message if the system…
Haas Parameter 747 PALLET POOL LIFT DOWN DWELL
Haas Parameter 747 PALLET POOL LIFT DOWN DWELL Specifies the dwell time, in milliseconds, to wait after the switch indicates that the lift is down before “down” is assumed.
Haas Parameter 814 AXIS PRESSURE TIMEOUT
Haas Parameter 814 AXIS PRESSURE TIMEOUT Specifies the duration in milliseconds after the start of the axis lubrication cycle, during which high pressure is expected to occur. If pressure is not…
Haas Parameter 748 PALLET POOL LIFT UP DWELL
Haas Parameter 748 PALLET POOL LIFT UP DWELL Specifies the dwell time, in milliseconds, to wait after the switch indicates that the lift is up before “up” is assumed.
Haas Parameter 749 FEED ACCEL ROUGH – Haas Mill
Haas Parameter 749 FEED ACCEL ROUGH – Haas Mill Applied when Rough smoothness is selected. See the definition for parameter 302.
Haas Parameter 750 FEED T CONST ROUGH – Haas Mill
Haas Parameter 750 FEED T CONST ROUGH – Haas Mill Applied when Rough smoothness is selected. See the definition for parameter 303.