Haas Parameters
Haas lathe/mill parameters
Haas Parameter 37 Z MAX ERROR
Haas Parameter 37 Z MAX ERROR See Parameter 9 for description.
Haas Parameter 38 Z FUSE LEVEL
Haas Parameter 38 Z FUSE LEVEL See Parameter 10 for description.
Haas Parameter 15 Y SWITCH A
Haas Parameter 15 Y SWITCH A See Parameter 1 for description.
Haas Parameter 16 Y P GAIN
Haas Parameter 16 Y P GAIN See Parameter 2 for description.
Haas Parameter 17 Y D GAIN
Haas Parameter 17 Y D GAIN See Parameter 3 for description.
Haas Parameter 18 Y I GAIN
Haas Parameter 18 Y I GAIN See Parameter 4 for description.
Haas Parameter 34 Z MAX TRAVEL (Steps)
Haas Parameter 34 Z MAX TRAVEL (Steps) See Parameter 6 for description.
Haas Parameter 24 Y FUSE LEVEL
Haas Parameter 24 Y FUSE LEVEL See Parameter 10 for description.
Haas Parameter 14 X DEAD ZONE
Haas Parameter 14 X DEAD ZONE Dead zone correction for driver electronics. Units are 0.0000001 seconds.
Haas Parameter 52 A FUSE LEVEL
Haas Parameter 52 A FUSE LEVEL See Parameter 10 for description.
Haas Parameter 20 Y MAX TRAVEL (Steps)
Haas Parameter 20 Y MAX TRAVEL (Steps) See Parameter 6 for description.
Haas Parameter 21 Y ACCELERATION
Haas Parameter 21 Y ACCELERATION See Parameter 7 for description.
Haas Parameter 22 Y MAX SPEED
Haas Parameter 22 Y MAX SPEED See Parameter 8 for description.
Haas Parameter 23 Y MAX ERROR
Haas Parameter 23 Y MAX ERROR See Parameter 9 for description.
Haas Parameter 7 X ACCELERATION
Haas Parameter 7 X ACCELERATION Maximum acceleration of axis in steps per second per second.
Haas Parameter 39 Z TORQUE PRELOAD – Haas Mill
Haas Parameter 39 Z TORQUE PRELOAD – Haas Mill See Parameter 11 for description.
Haas Parameter 8 X MAX SPEED
Haas Parameter 8 X MAX SPEED Maximum speed for this axis in steps per second.
Haas Parameter 40 Z STEPS/REVOLUTION
Haas Parameter 40 Z STEPS/REVOLUTION See Parameter 12 for description.
Haas Parameter 11 X BACK EMF – Haas Lathe
Haas Parameter 11 X BACK EMF – Haas Lathe Back EMF of motor in volts per 1000 rpm times 10. Thus a 63 volt/Krpm motor gives 630.
Haas Parameter 41 Z BACKLASH
Haas Parameter 41 Z BACKLASH See Parameter 13 for description.
Haas Parameter 12 X STEPS/REVOLUTION
Haas Parameter 12 X STEPS/REVOLUTION Encoder steps per revolution of motor. An 8192 line encoder gives: 8192 x 4 = 32768
Haas Parameter 42 Z DEAD ZONE
Haas Parameter 42 Z DEAD ZONE See Parameter 14 for description.
Haas Parameter 71 SPIN STALL DET DELAY – Haas Lathe
Haas Parameter 71 SPIN STALL DET DELAY – Haas Lathe Time to delay after spindle is started before spindle stall checking is started. Each unit is 1/50 of a second.
Haas Parameter 13 X BACKLASH
Haas Parameter 13 X BACKLASH Backlash correction in encoder steps.
Haas Parameter 44 A P GAIN
Haas Parameter 44 A P GAIN See Parameter 2 for description.
Haas Parameter 71 DRAW BAR OFFSET – Haas Mill
Haas Parameter 71 DRAW BAR OFFSET – Haas Mill Offset provided in motion of Z-axis to accommodate the tool pushing out of the spindle when unclamping. Units are encoder steps.
Haas Parameter 30 Z P GAIN
Haas Parameter 30 Z P GAIN See Parameter 2 for description.
Haas Parameter 31 Z D GAIN
Haas Parameter 31 Z D GAIN See Parameter 3 for description.
Haas Parameter 32 Z I GAIN
Haas Parameter 32 Z I GAIN See Parameter 4 for description.
Haas Parameter 49 A ACCELERATION
Haas Parameter 49 A ACCELERATION See Parameter 7 for description.
Haas Parameter 33 Z RATIO (Steps/Unit)
Haas Parameter 33 Z RATIO (Steps/Unit) See Parameter 5 for description.
Haas Parameter 50 A MAX SPEED
Haas Parameter 50 A MAX SPEED See Parameter 8 for description.
Haas Parameter 121 X PHASE OFFSET
Haas Parameter 121 X PHASE OFFSET The motor phase offset for X motor. Constant value, the value has no units.
Haas Parameter 53 A BACK EMF
Haas Parameter 53 A BACK EMF See Parameter 11 for description.
Haas Parameter 54 A STEPS/REVOLUTION
Haas Parameter 54 A STEPS/REVOLUTION See Parameter 12 for description.