Haas Parameters

Haas lathe/mill parameters

Haas Parameter 815 AXIS LUBE INPUT

Haas Parameter 815 AXIS LUBE INPUT Specifies the input relay for the axis lubrication pressure sensor. Active when Parameter 810 is ‘2’ or ‘3’.

Haas Parameter 831 LIVE TOOL STEPS/REV

Haas Parameter 831 LIVE TOOL STEPS/REV The control now accommodates a gear box to drive the live tooling, and provides different live tool revolution to motor revolution ratios other than 1…

Haas Parameter 816 AXIS LUBE OUTPUT

Haas Parameter 816 AXIS LUBE OUTPUT Specifies the output relay for the axis lubrication pump. Active when parameter 810 is ‘2’ or ‘3’.

Haas Parameter 832 COUNTER BAL CONFIG – Haas Mill

Haas Parameter 832 COUNTER BAL CONFIG – Haas Mill Specifies how pressure switches are connected. 0=The ESTOP input is connected in series with one or two counter balance system switches…

Haas Parameter 833 HI INTENSITY LIGHT

Haas Parameter 833 HI INTENSITY LIGHT Specifies the output relay to switch the high-intensity light (HIL) on and off.

Haas Parameter 834 AXIS MINIMUM RISE DELAY

Haas Parameter 834 AXIS MINIMUM RISE DELAY Used with grease reservoir type 3 in parameter 810. Specifies the minimum wait time in milliseconds for the grease pressure to rise after turning…

Haas Parameter 819 SPINDLE LUBE TIME INTERVAL

Haas Parameter 819 SPINDLE LUBE TIME INTERVAL Specifies the maximum number of minutes of spindle run-time, after which the spindle will be lubricated. No lubrication will be done if the machine…

Haas Parameter 836 UNCLAMP RAPID OVR

Haas Parameter 836 UNCLAMP RAPID OVR For tool changers with one-motion tool change (type 11 per parameter 710) this defines the speed of the tool arm, as a percentage of full…

Haas Parameter 837 CLAMP RAPID OVR

Haas Parameter 837 CLAMP RAPID OVR For tool changers with one-motion tool change (type 11 per parameter 710) this defines the speed of the tool arm, as a percentage of full…

Haas Parameter 838 SPINDLE ORIENT LOW PASS FILTER CUTOFF FREQUENCY

Haas Parameter 838 SPINDLE ORIENT LOW PASS FILTER CUTOFF FREQUENCY When the spindle is in orientation mode, this parameter enables the torque low pass filter to reduce high-frequency noise or vibration….

Haas Parameter 839 SUB SPINDLE ORIENT LOW PASS FILTER CUTOFF FREQUENCY

Haas Parameter 839 SUB SPINDLE ORIENT LOW PASS FILTER CUTOFF FREQUENCY When the subspindle is in orientation mode, this parameter enables the torque lowe pass filter to reduce highfrequency noise or…

Haas Parameter 840 SPINDLE ORIENT INTEGRAL GAIN

Haas Parameter 840 SPINDLE ORIENT INTEGRAL GAIN This parameter specifies the vector controller integral gain used in spindle orientation mode. It works in conjunction with Parameter 179. If Parameter 840 is…

Haas Parameter 841 SUB SPINDLE ORIENT INTEGRAL GAIN

Haas Parameter 841 SUB SPINDLE ORIENT INTEGRAL GAIN This parameter specifies the vector controller integral gain used in subspindle orientation mode.

Haas Parameter 842 SPINDLE PROPORTIONAL GAIN SCALE FACTOR

Haas Parameter 842 SPINDLE PROPORTIONAL GAIN SCALE FACTOR This parameter specifies the servo error threshold in encoder units (1-16) that determines whether the control will use full proportional gain or scaled…

Haas Parameter 827 SERVO DR SAFE ZONE

Haas Parameter 827 SERVO DR SAFE ZONE The region at which the Servo Auto Door is to decelerate using parameter 826 and to limit current using parameter 726. Units are inches…

Haas Parameter 843 SUB SPINDLE PROPORTIONAL GAIN SCALE FACTOR

Haas Parameter 843 SUB SPINDLE PROPORTIONAL GAIN SCALE FACTOR This parameter specifies the servo error threshold in encoder units (1-16) that determines whether the control will use full proportional gain or…

Haas Parameter 828 PROBE ARM HOME SW

Haas Parameter 828 PROBE ARM HOME SW The input port number on the IOPCB where the probe arm switch for the retract position is connected.

Haas Parameter 844 SPINDLE DYNAMIC GAIN TYPE

Haas Parameter 844 SPINDLE DYNAMIC GAIN TYPE When the servo error exceeds the threshold specified in parameter 842, this parameter value (1-3) defines the law used to scale down proportional gain:…

Haas Parameter 829 PROBE ARM DOWN SW

Haas Parameter 829 PROBE ARM DOWN SW The input port number on the IOPCB where the probe arm switch for the extended position is connected.

Haas Parameter 845 SUB SPINDLE DYNAMIC GAIN TYPE

Haas Parameter 845 SUB SPINDLE DYNAMIC GAIN TYPE When the servo error exceeds the threshold specified in parameter 843, this parameter value (1-3) defines the law used to scale down proportional…

Haas Parameter 847 SHOCK SENSOR INPUT

Haas Parameter 847 SHOCK SENSOR INPUT Shock sensor Input.

Haas Parameter 846 SHOCK SENSOR LOW PAS

Haas Parameter 846 SHOCK SENSOR LOW PAS Shock sensor low pas.

Haas Parameter 817 SPINDLE LUBE TYPE

Haas Parameter 817 SPINDLE LUBE TYPE Specifies which spindle lubrication system is installed. 0 or 1 Bijur oil system. The value sin parameter 818 through 822 2 Distance-based oil lubrication…

Haas Parameter 818 SPINDLE ROTATION INTERVAL

Haas Parameter 818 SPINDLE ROTATION INTERVAL Specifies the maximum number of spindle revolutions in thousands, after which the spindle will be lubricated. No lubrication will be done if the machine is…

Haas Parameter 835 AXIS MINIMUM FALL DELAY

Haas Parameter 835 AXIS MINIMUM FALL DELAY Used with Grease Reservoir type “3” in parameter 810. Specifies the minimum wait time in milliseconds for the grease pressure to remain high after…

Haas Parameter 852 G199 SPINDLE ACCELERATION

Haas Parameter 852 G199 SPINDLE ACCELERATION Maximum acceleration of the spindle assembly when G199 is engaged. This parameter is scaled by a factor of 1000, thus 2000 represents an acceleration of…

Haas Parameter 951 A SECONDARY ENCODER C

Haas Parameter 951 A SECONDARY ENCODER C Encoder input channel for use with linear or rotary scales.

Haas Parameter 853 G199 IN PHASE FILTER

Haas Parameter 853 G199 IN PHASE FILTER The amount of time that the spindles must be in phase before a G199 block is considered complete. Units are in milliseconds.

Haas Parameter 954 U SECONDARY ENCODER C

Haas Parameter 954 U SECONDARY ENCODER C Encoder input channel for use with linear or rotary scales.

Haas Parameter 854 G199 MAXIMUM RPM

Haas Parameter 854 G199 MAXIMUM RPM The maximum permitted RPM in G199 mode. Commanded RPM is clamped to this value. Units are in RPM.

Haas Parameter 855 G199 ACCEL LIMIT LOAD

Haas Parameter 855 G199 ACCEL LIMIT LOAD The maximum percentage load when synchronous spindle control is enabled with G199. It overrides parameters 196 and 554. Units are in percent. See parameter…

Haas Parameter 856 ACC X THRESHOLD

Haas Parameter 856 ACC X THRESHOLD Defines the limit for motion in the MainCON board vibration sensor’s X Axis. Parameter range is 1 to 15, representing 0.5g to 7.5g in 0.5g…

Haas Parameter 857 ACC Y THRESHOLD

Haas Parameter 857 ACC Y THRESHOLD Defines the limit for motion in the MainCON board vibration sensor’s Y Axis. Parameter range is 1 to 15, representing 0.5g to 7.5g in 0.5g…

Haas Parameter 1025 Sp DEADBAND

Haas Parameter 1025 Sp DEADBAND Deadband is a servo error region within which no control action will occur. This is mainly to prevent hunting around a settling point in PID servo…

Haas Parameter 863 SUB SPINDLE DECEL REF SPEED

Haas Parameter 863 SUB SPINDLE DECEL REF SPEED Specifies the secondary spindle deceleration reference speed. Units are RPM.