Haas Parameters

Haas lathe/mill parameters

Haas Parameter 509 C STEPS/REVOLUTION

Haas Parameter 509 C STEPS/REVOLUTION Encoder steps per revolution of motor. An 8192 line encoder gives: 8192 x 4 = 32768

Haas Parameter 515 C ACC/DEC T CONST

Haas Parameter 515 C ACC/DEC T CONST Exponential acceleration time constant. Units are 1/10000 seconds. This parameter provides for a constant ratio between profiling lag and servo velocity at the endpoint…

Haas Parameter 508 C BACK EMF

Haas Parameter 508 C BACK EMF Back EMF of motor in volts per 1000 rpm times 10. Thus a 63 volt/Krpm motor gives 630.

Haas Parameter 1027 SS DEADBAND

Haas Parameter 1027 SS DEADBAND Deadband is a servo error region within which no control action will occur. This is mainly to prevent hunting around a settling point in PID servo…

Haas Parameter 502 X RATIO (Steps/Unit)

Haas Parameter 502 X RATIO (Steps/Unit) Number of steps of encoder per unit of travel. Encoder steps supply four (4) times their line count per revolution. Thus, an 8192 line encoder…

Haas Parameter 479 Tt ACC/DEC T CONST

Haas Parameter 479 Tt ACC/DEC T CONST Exponential acceleration time constant. Units are 1/10000 seconds. This parameter provides for a constant ratio between profiling lag and servo velocity at the endpoint…

Haas Parameter 213 B TOOL CHANGE OFFSET – Haas Mill

Haas Parameter 213 B TOOL CHANGE OFFSET – Haas Mill Sets the distance between the B-axis grid offset (Parameter 170) and the spindle home position. The B-axis will be limited in…

Haas Parameter 212 A TOOL CHANGE OFFSET

Haas Parameter 212 A TOOL CHANGE OFFSET Sets the distance between the A-axis grid offset (Parameter 128) and the spindle home position. The A-axis is limited in movement to the area…

Haas Parameter 186 Sp DECELERATION

Haas Parameter 186 Sp DECELERATION See Parameter 10 for description. Maximum deceleration of axis in encoder steps per second per second.

Haas Parameter 10 X FUSE LEVEL

Haas Parameter 10 X FUSE LEVEL Limits average power to motor. If not set correctly, this parameter can cause an “overload” alarm.

Haas Parameter 184 Sp MAX ERROR

Haas Parameter 184 Sp MAX ERROR Maximum allowable error (in Hz) between commanded spindle speed and actual speed. If set to zero, it will default to 1/4 of Parameter 183.

Haas Parameter 159 B MAX ERROR

Haas Parameter 159 B MAX ERROR See Parameter 9 for description.

Haas Parameter 151 B SWITCH A

Haas Parameter 151 B SWITCH A See Parameter 1 for description.

Haas Parameter 127 Z GRID OFFSET

Haas Parameter 127 Z GRID OFFSET Shifts the effective position of the encoder Z pulse. It can correct for a motor or home switch positioning error.

Haas Parameter 126 Y GRID OFFSET

Haas Parameter 126 Y GRID OFFSET Shifts the effective position of the encoder Z pulse. It can correct for a motor or home switch positioning error.

Haas Parameter 125 X GRID OFFSET

Haas Parameter 125 X GRID OFFSET Shifts the effective position of the encoder Z pulse. It can correct for a motor or home switch positioning error.

Haas Parameter 75 GEAR CHANGE SPEED

Haas Parameter 75 GEAR CHANGE SPEED Command speed (maximum spindle rpm divided by 4096) used to rotate spindle motor when changing gears.

Haas Parameter 70 MIN SPIN DELAY TIME

Haas Parameter 70 MIN SPIN DELAY TIME Minimum delay time (in milliseconds) in program after commanding new spindle speed and before proceeding.

Haas Parameter 67 GEAR CHANGE DELAY

Haas Parameter 67 GEAR CHANGE DELAY Maximum delay allowed when changing gears. Units are milliseconds. After this time, an alarm is generated.

Haas Parameter 65 NUMBER OF TOOLS

Haas Parameter 65 NUMBER OF TOOLS Number of tool positions in tool changer. This number must be set to the configuration of the machine. The maximum number of tool positions is…

Haas Parameter 63 SHUTTLE STOP DELAY – Haas Mill

Haas Parameter 63 SHUTTLE STOP DELAY – Haas Mill Also used for vertical mills with Side-Mount Tool Changer. Specifies the time allowed (in milliseconds) for the tool arm motor to stop….

Haas Parameter 63 TURRET LOCK ERRTIME – Haas Lathe

Haas Parameter 63 TURRET LOCK ERRTIME – Haas Lathe Maximum delay allowed for tool turret to lock. Units are milliseconds. After this time, an alarm is generated.

Haas Parameter 61 TURRET STOP DELAY – Haas Mill

Haas Parameter 61 TURRET STOP DELAY – Haas Mill Maximum delay allowed in motion of tool turret. Units are milliseconds. After this time, an alarm is generated. On Horizontal mills with…

Haas Parameter 61 TURRET LOCK DELAY – Haas Lathe

Haas Parameter 61 TURRET LOCK DELAY – Haas Lathe Amount of time to delay after the turret is sensed to be locked. This delay allows for mechanical settling.

Haas Parameter 60 TURRET START DELAY – Haas Mill

Haas Parameter 60 TURRET START DELAY – Haas Mill Maximum delay allowed in start of tool turret. Units are milliseconds. After this time, an alarm is generated. On Horizontal mills with…

Haas Parameter 60 TURRET IN POS DELAY – Haas Lathe

Haas Parameter 60 TURRET IN POS DELAY – Haas Lathe Amount of time to delay after the turret rotates to the tool position. This delay allows the turret to settle.

Haas Parameter 59 MAX FEED (Inch/Min)

Haas Parameter 59 MAX FEED (Inch/Min) Maximum feedrate in inches per minute.

Haas Parameter 51 A MAX ERROR

Haas Parameter 51 A MAX ERROR See Parameter 9 for description.

Haas Parameter 43 A SWITCH A

Haas Parameter 43 A SWITCH A See Parameter 1 for bit descriptions.

Haas Parameter 737 COMMON SWITCH 5

Haas Parameter 737 COMMON SWITCH 5 0 LOCK OUT KBD TL CHG – When set to 1, no tool change performed when Power-Up-Restart is pressed. Also, when Power-Up-Restart, ATC FWD, ATC…

Haas Parameter 734 INPUT MASK (Used for the Office Mills) – Haas Mill

Haas Parameter 734 INPUT MASK (Used for the Office Mills) – Haas Mill 0 TOOL CHANGER IN . 1 TOOL CHANGER OUT . 2 TOOL #1 IN POSITION . 3…

Haas Parameter 734 INPUT MASK (Used for the Office Lathes) – Haas Lathe

Haas Parameter 734 INPUT MASK (Used for the Office Lathes) – Haas Lathe 0 TOOL TURRET UNLOCKD . 1 TOOL TURRET LOCKED . 2 C AXIS DISENGAGED . 3 SPARE…

Haas Parameter 715 COLOR MESSAGE

Haas Parameter 715 COLOR MESSAGE Used to change color of text messages displayed at bottom of an LCD monitor. The color chart can be displayed in Debug mode. Access Curnt Comands…

Haas Parameter 710 TOOL CHANGER TYPE – Haas Lathe

Haas Parameter 710 TOOL CHANGER TYPE – Haas Lathe Supports the lathe tool turrets. Set this parameter to 2 on lathes fitted with the 4-tool turret, set to 3 for…

Haas Parameter 701 LIVE TOOLING AXIS

Haas Parameter 701 LIVE TOOLING AXIS This parameter selects which MOCON channel the Live Tooling axis is used on. The value is 0-11, where 0=X-axis, 1=Y axis, etc. 0 – MOCON…