Haas Parameters

Haas lathe/mill parameters

Haas Parameter 644 X INDEXER INCREMENT

Haas Parameter 644 X INDEXER INCREMENT Note that only Parameters 647 and 648 for the A and B axes are intended to be used, and only on Horizontal Mills fitted with…

Haas Parameter 631 Ss PLUS TRAVEL LIMIT

Haas Parameter 631 Ss PLUS TRAVEL LIMIT Note that only Parameters 623 and 624 for the A and B axes are intended to be used, and only on Trunnion Mills (VF5TR…

Haas Parameter 620 X PLUS TRAVEL LIMIT

Haas Parameter 620 X PLUS TRAVEL LIMIT Note that only Parameters 623 and 624 for the A and B axes are intended to be used, and only on Trunnion Mills (VF5TR…

Haas Parameter 606 NUMBER OF PALLETS – Haas Mill

Haas Parameter 606 NUMBER OF PALLETS – Haas Mill Number of pallets present in the installed pallet changer. Also see Parameter 605. Pallet Changer Parameter 605 Parameter 606 APC (Pallet…

Haas Parameter 602 CHUCK FACE DISTANCE – Haas Lathe

Haas Parameter 602 CHUCK FACE DISTANCE – Haas Lathe Supports the brushless bar feeder. When executing G105 Q4, a new bar is loaded, measured and pushed through the spindle and halted…

Haas Parameter 599 Ss ENC. SCALE FACTOR

Haas Parameter 599 Ss ENC. SCALE FACTOR This axis parameter works in place of the axis parameters SCALE/X LO and SCALE/X HI. If SCALE FACT/X is set to 1, the scale…

Haas Parameter 588 X ENC. SCALE FACTOR

Haas Parameter 588 X ENC. SCALE FACTOR This axis parameter works in place of the axis parameters SCALE/X LO and SCALE/X HI. If SCALE FACT/X is set to 1, the scale…

Haas Parameter 562 Ss SWITCH B

Haas Parameter 562 Ss SWITCH B Parameter 562 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor arrows are used…

Haas Parameter 545 Ss MOT HI GEAR ST/REV

Haas Parameter 545 Ss MOT HI GEAR ST/REV Used when a Vector Drive is installed. It takes on two meanings, depending on how many spindle encoders are used on the machine….

Haas Parameter 534 Ss SWITCH A

Haas Parameter 534 Ss SWITCH A Parameter 534 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor arrows are used…

Haas Parameter 526 C SWITCH B

Haas Parameter 526 C SWITCH B Parameter 526 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor arrows are used…

Haas Parameter 498 C SWITCH A

Haas Parameter 498 C SWITCH A Parameter 498 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor arrows are used…

Haas Parameter 490 Tt SWITCH B

Haas Parameter 490 Tt SWITCH B Parameter 490 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor arrows are used…

Haas Parameter 462 Tt SWITCH A

Haas Parameter 462 Tt SWITCH A Parameter 462 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor arrows are used…

Haas Parameter 454 W SWITCH B

Haas Parameter 454 W SWITCH B Parameter 454 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor arrows are used…

Haas Parameter 426 W SWITCH A

Haas Parameter 426 W SWITCH A Parameter 426 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor arrows are used…

Haas Parameter 418 V SWITCH B

Haas Parameter 418 V SWITCH B Parameter 418 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor arrows are used…

Haas Parameter 390 V SWITCH A

Haas Parameter 390 V SWITCH A Parameter 390 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor arrows are used…

Haas Parameter 352 RELAY BANK SELECT

Haas Parameter 352 RELAY BANK SELECT Allows the user to change which bank of relays is to be used (Parameter 209, bit 23, MCD RLY BRD assumes that relay bank one…

Haas Parameter 315 COMMON SWITCH 4 – Haas Mill

Haas Parameter 315 COMMON SWITCH 4 – Haas Mill 0 ALIS M GRPHC – When this bit is set to 0, all user defined M codes (such as M50, normally…

Haas Parameter 315 COMMON SWITCH 4 – Haas Lathe

Haas Parameter 315 COMMON SWITCH 4 – Haas Lathe 0 ALIS M GRPHC – All user defined M codes (such as M50) are ignored when a program is run in…

Haas Parameter 278 COMMON SWITCH 3 – Haas Mill

Haas Parameter 278 COMMON SWITCH 3 – Haas Mill Parameter 278 is a collection of general purpose single bit flags used to turn some functions on and off. This bit…

Haas Parameter 278 COMMON SWITCH 3 – Haas Lathe

Haas Parameter 278 COMMON SWITCH 3 – Haas Lathe Parameter 278 is a collection of general purpose single bit flags used to turn some functions on and off. Left and right…

Haas Parameter 271 Sp SWITCH B – Haas Mill

Haas Parameter 271 Sp SWITCH B – Haas Mill Parameter 271 is a collection of single-bit flags used to turn servo related functions on and off. This parameter is not used…

Haas Parameter 271 Sp SWITCH B – Haas Lathe

Haas Parameter 271 Sp SWITCH B – Haas Lathe Parameter 271 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor…

Haas Parameter 270 B SWITCH B – Haas Mill

Haas Parameter 270 B SWITCH B – Haas Mill Parameter 270 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor…

Haas Parameter 270 B SWITCH B – Haas Lathe

Haas Parameter 270 B SWITCH B – Haas Lathe Parameter 270 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor…

Haas Parameter 269 A SWITCH B – Haas Mill

Haas Parameter 269 A SWITCH B – Haas Mill Parameter 269 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor…

Haas Parameter 269 A SWITCH B – Haas Lathe

Haas Parameter 269 A SWITCH B – Haas Lathe Parameter 269 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor…

Haas Parameter 268 Z SWITCH B – Haas Mill

Haas Parameter 268 Z SWITCH B – Haas Mill Parameter 268 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor…

Haas Parameter 268 Z SWITCH B – Haas Lathe

Haas Parameter 268 Z SWITCH B – Haas Lathe Parameter 268 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor…

Haas Parameter 267 Y SWITCH B – Haas Mill

Haas Parameter 267 Y SWITCH B – Haas Mill Parameter 267 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor…

Haas Parameter 267 Y SWITCH B – Haas Lathe

Haas Parameter 267 Y SWITCH B – Haas Lathe Parameter 267 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor…

Haas Parameter 254 TC AIR DOOR CLEARANCE – Haas Mill

Haas Parameter 254 TC AIR DOOR CLEARANCE – Haas Mill Incorporates the X-axis door clearance for the Mini-horizontal. This position is used during a tool change to avoid hitting the tool…

Haas Parameter 209 COMMON SWITCH 2 – Haas Mill

Haas Parameter 209 COMMON SWITCH 2 – Haas Mill Parameter 209 is a collection of general purpose single bit flags used to turn some functions on and off. Use left…