Haas Parameters
Haas lathe/mill parameters
Haas Parameter 209 COMMON SWITCH 2 – Haas Lathe
Haas Parameter 209 COMMON SWITCH 2 – Haas Lathe Parameter 209 is a collection of general purpose single bit flags used to turn some functions on and off. Use left and…
Haas Parameter 187 Sp MOT HI GEAR ST/REV
Haas Parameter 187 Sp MOT HI GEAR ST/REV Used when a Vector Drive is installed. It takes on two meanings, depending on how many spindle encoders are used on the machine….
Haas Parameter 143 LIVE TOOL CHNG VEL – Haas Lathe
Haas Parameter 143 LIVE TOOL CHNG VEL – Haas Lathe Velocity to command the Live Tooling Drive motor for the period specified by Parameter 72. This process is required to engage…
Haas Parameter 142 HIGH/LOW GEAR CHANG
Haas Parameter 142 HIGH/LOW GEAR CHANG Sets the spindle speed at which an automatic gear change is performed. Below this parameter, low gear is the default; above this, high gear is…
Haas Parameter 131 MAX SPINDLE RPM
Haas Parameter 131 MAX SPINDLE RPM Maximum rpm available to the spindle. When this speed is programmed, the D-to-A output will be +10V and the spindle drive must be calibrated to…
Haas Parameter 128 A GRID OFFSET
Haas Parameter 128 A GRID OFFSET Shifts the effective position of the encoder Z pulse. It can correct for a motor or home switch positioning error.
Haas Parameter 117 LUB CYCLE TIME
Haas Parameter 117 LUB CYCLE TIME If this is set nonzero, it is the cycle time for the lube pump. The Lube pressure switch option is checked for cycling in this…
Haas Parameter 101 X IN POSITION LIMIT
Haas Parameter 101 X IN POSITION LIMIT How close the motor must be to the endpoint before any move is considered complete when not in exact stop (G09 or G61). Units…
Haas Parameter 91 G MACRO CALL O9010
Haas Parameter 91 G MACRO CALL O9010 G code that calls O9010, and can contain a value from 1 through 98, inclusive. Zero causes no call; however, it is best to…
Haas Parameter 81 M MACRO CALL O9000
Haas Parameter 81 M MACRO CALL O9000 M code that will call O9000. This parameter can contain a value from 1 through 98, inclusive. Zero causes no call; however, it is…
Haas Parameter 79 SPINDLE STEPS/REV
Haas Parameter 79 SPINDLE STEPS/REV Sets the number of spindle encoder steps per revolution of the spindle. This number takes into account the pulley ratio between transmission and spindle, plus transmission…
Haas Parameter 76 LOW AIR DELAY
Haas Parameter 76 LOW AIR DELAY Delay allowed after sensing low air pressure before alarm is generated. Alarm skipped if air pressure returns before delay. Units are 1/50 second.
Haas Parameter 72 LIVE TOOL CHNG DLAY – Haas Lathe
Haas Parameter 72 LIVE TOOL CHNG DLAY – Haas Lathe Amount of time (in milli seconds) to wait after commanding the Live Tooling Drive motor to turn at the velocity specified…
Haas Parameter 64 Z TOOL CHANGE OFFSET
Haas Parameter 64 Z TOOL CHANGE OFFSET For turret, displacement from home switch to tool 0. On Vertical mills: For Z-axis; displacement from home switch to tool change position and…
Haas Parameter 62 SHUTTLE START DELAY – Haas Mill
Haas Parameter 62 SHUTTLE START DELAY – Haas Mill The time (in milliseconds) needed to allow the tool pocket to settle (stop bouncing) after being lowered in preparation for a tool…
Haas Parameter 62 TURRET UNLK ERRTIME – Haas Lathe
Haas Parameter 62 TURRET UNLK ERRTIME – Haas Lathe Maximum delay allowed for tool turret to unlock. Units are milliseconds. After this time, an alarm is generated.
Haas Parameter 57 COMMON SWITCH 1
Haas Parameter 57 COMMON SWITCH 1 Parameter 57 is a collection of general purpose single bit flags used to turn some functions on and off. Left and right cursor arrows select…
Haas Parameter 48 A MAX TRAVEL (Negative Travel Limit) (Steps)
Haas Parameter 48 A MAX TRAVEL (Negative Travel Limit) (Steps) See Parameter 6 for description. Normally this parameter would not apply to the A axis; however, this parameter is used on…
Haas Parameter 47 A RATIO (Steps/Unit) – Haas Mill
Haas Parameter 47 A RATIO (Steps/Unit) – Haas Mill Defines number of encoder steps required or one full platter rotation. For example, an HRT 210 with a 90:1 gear ratio, a…
Haas Parameter 11 X TORQUE PRELOAD – Haas Mill
Haas Parameter 11 X TORQUE PRELOAD – Haas Mill Torque Preload is a signed number that should be set to a value from 0 to 4095, where 4095 is the…
Haas Parameter 9 X MAX ERROR
Haas Parameter 9 X MAX ERROR Maximum error allowed in servo loop before alarm is generated. Units are encoder steps. This is the maximum allowable error in Hz between commanded speed…
Haas Parameter 5 X RATIO (Steps/Unit)
Haas Parameter 5 X RATIO (Steps/Unit) Number of steps of encoder per unit of travel. Encoder steps supply four (4) times their line count per revolution. Thus, an 8192 line…
Haas Parameter 1 X SWITCH A
Haas Parameter 1 X SWITCH A Parameter 1 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor arrows are used…
Haas Parameter 257 SPINDL ORIENT OFSET
Haas Parameter 257 SPINDL ORIENT OFSET If equipped with spindle vector drive (as set in bit 7 of Parameter 278), this bit sets spindle orientation offset. The offset is the number…
Haas Parameter 258 COLD SPINDLE TEMP – Haas Mill
Haas Parameter 258 COLD SPINDLE TEMP – Haas Mill The first time Cycle Start is pressed after the machine has been turned on, control compares microprocessor temperature (in degrees Fahrenheit) against…
Haas Parameter 259 COLD SPINDLE DAYS – Haas Mill
Haas Parameter 259 COLD SPINDLE DAYS – Haas Mill The first time Cycle Start is pressed after the machine is turned on, the control will compare the number of days that…
Haas Parameter 266 X SWITCH B – Haas Lathe
Haas Parameter 266 X SWITCH B – Haas Lathe Parameter 266 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor…
Haas Parameter 266 X SWITCH B – Haas Mill
Haas Parameter 266 X SWITCH B – Haas Mill Parameter 266 is a collection of single-bit flags used to turn servo related functions on and off. The left and right cursor arrows…