Haas Parameters

Haas lathe/mill parameters

Haas Parameter 107 Z MAX CURRENT

Haas Parameter 107 Z MAX CURRENT See Parameter 105 (M) for description.

Haas Parameter 146 Y ACCEL FEED FORWARD

Haas Parameter 146 Y ACCEL FEED FORWARD Set the feed forward gain for the axis servo. Constant value, it has no units.

Haas Parameter 56 A DEAD ZONE

Haas Parameter 56 A DEAD ZONE See Parameter 14 for description.

Haas Parameter 108 A MAX CURRENT

Haas Parameter 108 A MAX CURRENT See Parameter 105 (M) for description.

Haas Parameter 147 Z ACCEL FEED FORWARD

Haas Parameter 147 Z ACCEL FEED FORWARD Set the feed forward gain for the axis servo. Constant value, it has no units.

Haas Parameter 58 LEAD COMPENS SHIFT

Haas Parameter 58 LEAD COMPENS SHIFT Shift factor when applying lead screw compensation. Lead screw compensation is based on a table of 256 offsets; each +-127 encoder steps. A single entry…

Haas Parameter 109 X D*D GAIN

Haas Parameter 109 X D*D GAIN Second derivative gain in servo loop.

Haas Parameter 148 A ACCEL FEED FORWARD

Haas Parameter 148 A ACCEL FEED FORWARD Set the feed forward gain for the axis servo. Constant value, it has no units.

Haas Parameter 66 SPINDLE ORI DELAY

Haas Parameter 66 SPINDLE ORI DELAY Maximum delay allowed when orienting spindle. Units are milliseconds. After this time, an alarm is generated.

Haas Parameter 149 PRE-CHARGE DELAY – Haas Mill

Haas Parameter 149 PRE-CHARGE DELAY – Haas Mill Sets the delay time from precharge to tool release. Units are milliseconds.

Haas Parameter 68 DRAW BAR MAX DELAY – Haas Mill

Haas Parameter 68 DRAW BAR MAX DELAY – Haas Mill Maximum delay allowed when clamping and unclamping tool. Units are milliseconds. After this time, an alarm is generated.

Haas Parameter 69 A AIR BRAKE DELAY

Haas Parameter 69 A AIR BRAKE DELAY Delay provided for air to release from brake on A-axis prior to moving. Units are milliseconds.

Haas Parameter 134 X EXACT STOP DIST.

Haas Parameter 134 X EXACT STOP DIST. This parameter controls how close the axis must be to its end point when exact stop is programmed. They apply in G09 and G64.They…

Haas Parameter 135 Y EXACT STOP DIST.

Haas Parameter 135 Y EXACT STOP DIST. This parameter controls how close the axis must be to its end point when exact stop is programmed. They apply in G09 and G64.They…

Haas Parameter 136 Z EXACT STOP DIST.

Haas Parameter 136 Z EXACT STOP DIST. This parameter controls how close the axis must be to its end point when exact stop is programmed. They apply in G09 and G64.They…

Haas Parameter 45 A D GAIN

Haas Parameter 45 A D GAIN See Parameter 3 for description.

Haas Parameter 72 DRAW BAR Z VEL UNCL – Haas Mill

Haas Parameter 72 DRAW BAR Z VEL UNCL – Haas Mill Speed of motion in Z-axis to accommodate tool pushing out of the spindle when unclamping. Units are encoder steps per…

Haas Parameter 137 A EXACT STOP DIST.

Haas Parameter 137 A EXACT STOP DIST. This parameter controls how close the axis must be to its end point when exact stop is programmed. They apply in G09 and G64.They…

Haas Parameter 46 A I GAIN

Haas Parameter 46 A I GAIN See Parameter 4 for description.

Haas Parameter 47 A RATIO (Steps/Unit) – Haas Lathe

Haas Parameter 47 A RATIO (Steps/Unit) – Haas Lathe See Parameter 5 for description.

Haas Parameter 118 SPINDLE REV TIME

Haas Parameter 118 SPINDLE REV TIME Time in milliseconds to reverse spindle motor.

Haas Parameter 119 SPINDLE DECEL DELAY

Haas Parameter 119 SPINDLE DECEL DELAY Time in milliseconds to decelerate spindle motor.

Haas Parameter 120 SPINDLE ACC/DECEL

Haas Parameter 120 SPINDLE ACC/DECEL Accel/decel time constant in 200ths of a step/ms/ms for spindle motor.

Haas Parameter 121 X PHASE OFFSET

Haas Parameter 121 X PHASE OFFSET The motor phase offset for X motor. Constant value, the value has no units.

Haas Parameter 105 X MAX CURRENT

Haas Parameter 105 X MAX CURRENT Fuse level in % of max power to motor. Applies only when motor is stopped. Corresponds to maximum peak current provided by the amplifier. 4095…

Haas Parameter 144 RIG TAP FINISH DIST

Haas Parameter 144 RIG TAP FINISH DIST Sets the finish tolerance for determining the end point of a rigid tapping operation. Units are encoder counts.

Haas Parameter 106 Y MAX CURRENT

Haas Parameter 106 Y MAX CURRENT See Parameter 105 (M) for description.

Haas Parameter 145 X ACCEL FEED FORWARD

Haas Parameter 145 X ACCEL FEED FORWARD Set the feed forward gain for the axis servo. Constant value, it has no units.

Haas Parameter 129 GEAR CH SETTLE TIME

Haas Parameter 129 GEAR CH SETTLE TIME Gear change settle time. This is the number of one millisecond samples that the gear status must be stable before considered in gear.

Haas Parameter 130 GEAR STROKE DELAY

Haas Parameter 130 GEAR STROKE DELAY Controls the delay time to the gear change solenoids when performing a gear change.

Haas Parameter 132 Y SCREW COMP. COEF.

Haas Parameter 132 Y SCREW COMP. COEF. Coefficient of heating of the ballscrew, and is used to decrease or shorten the screw length.

Haas Parameter 133 Z SCREW COMP. COEF.

Haas Parameter 133 Z SCREW COMP. COEF. Coefficient of heating of the ballscrew, and is used to decrease or shorten the screw length.

Haas Parameter 113 X ACC/DEC T CONST

Haas Parameter 113 X ACC/DEC T CONST Exponential acceleration time constant. Units are 1/10000 seconds. This parameter provides for a constant ratio between profiling lag and servo velocity at the endpoint…

Haas Parameter 114 Y ACC/DEC T CONST

Haas Parameter 114 Y ACC/DEC T CONST See Parameter 113 for description.

Haas Parameter 115 Z ACC/DEC T CONST

Haas Parameter 115 Z ACC/DEC T CONST See Parameter 113 for description.