Haas Parameters
Haas lathe/mill parameters
Haas Parameter 304 SPIGOT REV POS DLY – Haas Mill
Haas Parameter 304 SPIGOT REV POS DLY – Haas Mill Length of a delay (units are ms) when moving the coolant spigot in reverse. This parameter should be set to…
Haas Parameter 328 Y SCALES PER INCH
Haas Parameter 328 Y SCALES PER INCH Used on machines equipped with linear scales.
Haas Parameter 305 SERVO PO BRK DLY – Haas Lathe
Haas Parameter 305 SERVO PO BRK DLY – Haas Lathe Time (in milliseconds) that the control should wait after turning off the Hyd Pump Enable relay (which will activate the brake)…
Haas Parameter 318 APC PAL. CHAIN TIME – Haas Mill
Haas Parameter 318 APC PAL. CHAIN TIME – Haas Mill Time required to cycle the chain. It should be set to 8000. Units are milliseconds.
Haas Parameter 319 MAX RETRACT POS – Haas Lathe
Haas Parameter 319 MAX RETRACT POS – Haas Lathe Supports Haas Servo Bar 300 bar feeder. This is maximum V axis retracted position. Units are inches * 10000.
Haas Parameter 319 APC DOOR CLOSE TIME – Haas Mill
Haas Parameter 319 APC DOOR CLOSE TIME – Haas Mill Time required to close the door. It should be set to 6000. Units are milliseconds.
Haas Parameter 320 MIN RETRACT DIST – Haas Lathe
Haas Parameter 320 MIN RETRACT DIST – Haas Lathe Supports Haas Servo Bar 300 bar feeder. This is the minimum space between bar and push rod when retracted. Units are inches*10,000
Haas Parameter 320 RP DRAWBAR DOWN – Haas Mill
Haas Parameter 320 RP DRAWBAR DOWN – Haas Mill Time required for the drawbar to move down. Units are milliseconds.
Haas Parameter 309 ARM START TIMEOUT – Haas Mill
Haas Parameter 309 ARM START TIMEOUT – Haas Mill Supports side-mount tool changers. It specifies time allowed for the tool changer to start only. If the arm has not moved after…
Haas Parameter 321 PUSH ROD ZERO POS – Haas Lathe
Haas Parameter 321 PUSH ROD ZERO POS – Haas Lathe Supports the Haas Servo Bar 300 bar feeder. This is the V axis position for loading and unloading a bar….
Haas Parameter 335 Z SCALES PER REV
Haas Parameter 335 Z SCALES PER REV Used on machines equipped with linear scales.
Haas Parameter 310 CAM LOCK DELAY – Haas Mill
Haas Parameter 310 CAM LOCK DELAY – Haas Mill Supports side-mount tool changers. It specifies the time allowed (in milliseconds) to lock the cam by pushing the shot pin in, or…
Haas Parameter 336 A SCALES PER REV
Haas Parameter 336 A SCALES PER REV Used on machines equipped with linear scales.
Haas Parameter 311 ARM BUMP TIME/DEG – Haas Mill
Haas Parameter 311 ARM BUMP TIME/DEG – Haas Mill Supports side-mount tool changers. During tool change recovery, the arm may be moved a small amount by pressing the ATC FWD or…
Haas Parameter 312 CAROUSEL BUMP TIME – Haas Mill
Haas Parameter 312 CAROUSEL BUMP TIME – Haas Mill Supports side-mount tool changers. During tool change recovery, the carousel may be moved a small amount by pressing the Left Arrow or…
Haas Parameter 313 POCKET INCREMENT – Haas Mill
Haas Parameter 313 POCKET INCREMENT – Haas Mill Used for the bridge mill. Under normal circumstances it should be set to 1. If, for example, it is set to 2,…
Haas Parameter 314 FEED DELTA V MEDIUM – Haas Mill
Haas Parameter 314 FEED DELTA V MEDIUM – Haas Mill Supports motion control. It is the maximum change in velocity (in encoder steps per millisecond) allowed between motion steps when Medium…
Haas Parameter 323 TOOL CLEAN 1 OFF – Haas Mill
Haas Parameter 323 TOOL CLEAN 1 OFF – Haas Mill Tool arm angle to start air blast Units are degrees x 1000.
Haas Parameter 324 GEAR MOTOR SETTLE – Haas Lathe
Haas Parameter 324 GEAR MOTOR SETTLE – Haas Lathe Supports the Haas Servo Bar 300 bar feeder. This is the minimum dwell time for reversing the gear motor direction. Units are…
Haas Parameter 325 STANDARD BAR LEN – Haas Lathe
Haas Parameter 325 STANDARD BAR LEN – Haas Lathe Supports Haas Servo Bar 300 bar feeder. This is length of bar for G105 Q5. Units are in inches per minute*1000.
Haas Parameter 326 G5 DECELERATION – Haas Lathe
Haas Parameter 326 G5 DECELERATION – Haas Lathe Supports the G05 Fine Spindle Ctrl feature. This is the rate at which to decelerate the spindle during G5. Units are in encoder…
Haas Parameter 317 APC UNCLAMP TIME – Haas Mill
Haas Parameter 317 APC UNCLAMP TIME – Haas Mill Time required to unclamp the APC pallet from the receiver. Units are milliseconds.
Haas Parameter 346 Y SPINDLE THERM T.C.
Haas Parameter 346 Y SPINDLE THERM T.C. See Parameter 345 for description.
Haas Parameter 318 GEAR MOTOR TIMEOUT – Haas Lathe
Haas Parameter 318 GEAR MOTOR TIMEOUT – Haas Lathe Supports Haas Servo Bar 300 bar feeder. This is timeout value for gearmotor operations. Units are in milliseconds.
Haas Parameter 347 Z SPINDLE THERM T.C.
Haas Parameter 347 Z SPINDLE THERM T.C. See Parameter 345 for description.
Haas Parameter 348 A SPINDLE THERM T.C.
Haas Parameter 348 A SPINDLE THERM T.C. See Parameter 345 for description.
Haas Parameter 386 V SCALES PER INCH
Haas Parameter 386 V SCALES PER INCH Used on machines equipped with linear scales.
Haas Parameter 349 B SPINDLE THERM T.C.
Haas Parameter 349 B SPINDLE THERM T.C. See Parameter 345 for description.
Haas Parameter 391 V P GAIN
Haas Parameter 391 V P GAIN Proportional gain in servo loop.
Haas Parameter 351 THRML SENSOR OFFSET
Haas Parameter 351 THRML SENSOR OFFSET Used for Ballscrew Thermal Compensation via a temperature sensor attached to the ball nut.
Haas Parameter 392 V D GAIN
Haas Parameter 392 V D GAIN Derivative gain in servo loop.
Haas Parameter 393 V I GAIN
Haas Parameter 393 V I GAIN Integral gain in servo loop.
Haas Parameter 308 ARM ROTATE TIME – Haas Mill
Haas Parameter 308 ARM ROTATE TIME – Haas Mill Supports the side-mount tool changers. It specifies the time allowed (in milliseconds) for the arm to rotate to the next position. The…
Haas Parameter 334 Y SCALES PER REV
Haas Parameter 334 Y SCALES PER REV Used on machines equipped with linear scales.
Haas Parameter 371 U ACC/DEC T CONST
Haas Parameter 371 U ACC/DEC T CONST Exponential acceleration time constant. Units are 1/10000 seconds. This parameter provides for a constant ratio between profiling lag and servo velocity at the endpoint…