Okuma Alarm-D 4037 CCP-CPU error
An error occurred in the CCP-CPU used for DNC-B specification.
(To release this alarm,turn off the power and then turn it on.)
Code
1->A memory parity/write error occurred in the CCP memory test.
2->The CCP control program was not be properly loaded.
3->The CCP communication program was not properly activated.
4->The CCP communication channel was not properly opened.
5->A CCP self-diagnostic error occurred.
6->The CCP-CPU caused an exception error.
7->An error occurred in CCP control program operation.
8->An error occurred in CCP control program operation.
9->An error occurred in CCP control program operation.
Measures to Take
Faulty CCP board
Check if the memory stores the CCP control software.
Faulty memory
CCP control software error
CCP board switch setting error