An error occurred in the CCP-CPU used for DNC-B specification.
(To release this alarm,turn off the power and then turn it on.)

Code
1->A memory parity/write error occurred in the CCP memory test.
2->The CCP control program was not be properly loaded.
3->The CCP communication program was not properly activated.
4->The CCP communication channel was not properly opened.
5->A CCP self-diagnostic error occurred.
6->The CCP-CPU caused an exception error.
7->An error occurred in CCP control program operation.

(Task control error)

8->An error occurred in CCP control program operation.

(Real-time task loop error)

9->An error occurred in CCP control program operation.

(Control error in switching time-shared tasks)

Measures to Take
Faulty CCP board
Check if the memory stores the CCP control software.
Faulty memory
CCP control software error
CCP board switch setting error