Okuma Alarm-D 4225 Pitch compensation data calculation
In simplified pitch error compensation, the number of compensation points is not between 1 and 299 because stroke end limit data or pitch amount is not set correctly.
Probable Faulty Locations
Travel end limit data or pitch amount