Okuma Alarm-D 4704 Please open door


Okuma Alarm-D 4704 Please open door
In the door interlock S specifications, this message appears when the door or the roof door or the tailstock maintenance door or right/left front door or the operation door or the APC door, open/close confirmation switch is in CLOSE positionwith the power ON.
Check if this switch operates normally by opening the door with the help of the other operator.

Related Specifications
Door Interlock S

Okuma Alarm-D 4704 Please open door