Okuma Alarms Errors

Okuma alarms and errors.

Okuma Alarm-B 2569 Thermal deviation comp. backup failure

Okuma Alarm-B 2569 Thermal deviation comp. backup failure There is no thermal deviation compensation backup file or writing to the backup file is disabled. Index None Character-string None Code 1->There…

Okuma Alarm-B 2570 W-axis position condition

Okuma Alarm-B 2570 W-axis position condition G154 command was specified without designation of W-axis command. Code 1->G154 command was specified without designation of W-axis command. 2->G154 command was performed by…

Okuma Alarm-B 2571 W-axis position no spec.

Okuma Alarm-B 2571 W-axis position no spec. G154 was specified thought the machine was not equipped with B-axis control function, two saddles, and sub spindle. Concerning Sub spindle-tailstock Control specification,…

Okuma Alarm-B 2565 Load monitor system variable

Okuma Alarm-B 2565 Load monitor system variable In the Load-monitor specification, 1)BASE or 1st-limit,2nd-limit of the axis which does not exist for the Load-monitor was about to be read or…

Okuma Alarm-B 2566 MULTI-MACHINING CYCLE No M-tool cycle command

Okuma Alarm-B 2566 MULTI-MACHINING CYCLE No M-tool cycle command When MULTI-MACHINING CYCLE command was performed, M-axis was a stopped state. MULTI-MACHINING CYCLE command:G181,G182,G183,G185,G186,G187 G188,G189,G190

Okuma Alarm-B 2567 No helical cutting specifications

Okuma Alarm-B 2567 No helical cutting specifications When the helical-cut specification is not selected or the slant process mode is established, a circular-cut command and on X-,Y-,Z-axis command are specified…

Okuma Alarm-B 2568 Mistake in OF command

Okuma Alarm-B 2568 Mistake in OF command ‘OF’ command was ordered in a block there was ‘T’ command or ‘TL’, ‘TG’. Object SYSTEM Probable Faulty Locations 1)Program error : T010101…

Okuma Alarm-B 2573 Taper cutting cycle

Okuma Alarm-B 2573 Taper cutting cycle Taper cutting cycle order is illegal. Object SYSTEM Character-string None Code 1-> It was not in turning mode. 2-> Taper shape is illegal. Probable…

Okuma Alarm-B 2575 Mistake in ‘TD’,’TDG’,’OS’ commands

Okuma Alarm-B 2575 Mistake in ‘TD’,’TDG’,’OS’ commands Specified TD ,TDG ,OS command was illegal. Object SYSTEM Code X 1 : Wrong TOOL number in TD COMMAND 2 : Wrong TOOL…

Okuma Alarm-B 2576 Mistake in H command

Okuma Alarm-B 2576 Mistake in H command In the spec of Zero offset 10 or 50 or 100 set: H command is incorrect.The H command value specified together with G15/G16…

Okuma Alarm-B 2577 No axis movement command

Okuma Alarm-B 2577 No axis movement command Axis command is designed although the axis movement instruction not performed. Code None Probable Faulty Locations Programming error Measures to Take Correct the…

Okuma Alarm-B 2578 NO D COMMAND

Okuma Alarm-B 2578 NO D COMMAND When setting values for D(cam major axis) and L(cam lift) in the cam define data file(LSF), no value is set for D. Index None…

Okuma Alarm-B 2579 NO L COMMAND

Okuma Alarm-B 2579 NO L COMMAND When setting values for D(cam major axis) and L(cam lift) in the cam define data file(LSF), no value is set for D. Index None…

Okuma Alarm-B 2580 Mistake in XS command

Okuma Alarm-B 2580 Mistake in XS command Illegal Xs-axis(cam-axis) positioning command (asynchronous mode command). Index None Character-string None Code 1->Xs-axis rapid positioning command is designated in the synchronous mode. 2->Xs-axis…

Okuma Alarm-B 2564 Index disable position

Okuma Alarm-B 2564 Index disable position Concernig B-axis 1/1000 spec and pendulum-control spec, Index disable point was designated. Code None Probable Faulty Locations 1)Program error Measures to Take Please order…

Okuma Alarm-B 2581 CAM data deployment mode

Okuma Alarm-B 2581 CAM data deployment mode In the cam execute data develop mode, a value is set to D (major diameter of the eclipse) and L(cam lift value) in…

Okuma Alarm-B 2582 CAM data file write protect

Okuma Alarm-B 2582 CAM data file write protect The cam execute data file(EXF file) is in the write-protected condition when an attempt is made to update the file. Index None…

Okuma Alarm-B 2583 Compensation value overflow

Okuma Alarm-B 2583 Compensation value overflow Overflow occurred when calculating the initial value of the compensation value. Index None Character-string None Code Hexadecimal of the compensation value. Probable Faulty Locations…

Okuma Alarm-B 2584 CON speed XS-axis

Okuma Alarm-B 2584 CON speed XS-axis The command value and the compensation value of the cam execute data exceeded the allowable spindle speed when writing these values in the memory….

Okuma Alarm-B 2585 XS-axis command turret mode

Okuma Alarm-B 2585 XS-axis command turret mode A command related with the Xs-axis designated while the B-turret is selected. Index None Character-string None Code None 1-> A FCALL commands is…

Okuma Alarm-B 2594 Mistake in RJ command

Okuma Alarm-B 2594 Mistake in RJ command Value of ‘RJ’ command is over the range that be from 1 to 999. Code Hexadecimal of ‘RJ’ command

Okuma Alarm-B 2595 Synchronized rotation speed over

Okuma Alarm-B 2595 Synchronized rotation speed over In Hob Cuttnig Synchronous mode, an attempt is made to rotate the M-tool spindle at a speed higher than the main spindle allowable…

Okuma Alarm-B 2596 Synchronized tap overload

Okuma Alarm-B 2596 Synchronized tap overload The load torque of M-axis exceeded a set value while synchronized tap. Object SYSTEM Index None Character-string None Probable Faulty Locations Cutting load is…

Okuma Alarm-B 2587 No A command

Okuma Alarm-B 2587 No A command The shape of off-center circle was define with D(diameter of off-center circle), L(offset amount), and OF(offset amount of reference position). But, the definition file(LSF…

Okuma Alarm-B 2588 Mistake in OF command

Okuma Alarm-B 2588 Mistake in OF command The shape of off-center circle was define with A(reference angle for development), D(diameter of off-center circle), L(offset amount), and OF(offset amount of reference…

Okuma Alarm-B 2589 Definition conditions

Okuma Alarm-B 2589 Definition conditions Among the commands for defining the off-center circle in the shape definition file(LSF file), the relation between D command value(diameter of off-center circle) and L…

Okuma Alarm-B 2590 Y-axis command

Okuma Alarm-B 2590 Y-axis command In case of “Y-axis tool offset” was changed in G136-mode, movement-command except for G00/G136/G138 was instructed when “Y-axis tool offset” was not effective. Code 1…

Okuma Alarm-B 2591 Mistake in point command

Okuma Alarm-B 2591 Mistake in point command Though it was not transportation mode, axis-movement by a point instruction had instructed. A value beyond limits was about to be setting on…

Okuma Alarm-B 2593 Mistake in CF command

Okuma Alarm-B 2593 Mistake in CF command Value of ‘CF’ command is over the range that be from 0 to 359999. Code Hexadecimal of ‘CF’ command

Okuma Alarm-B 2586 Synchronous mode execution impossible

Okuma Alarm-B 2586 Synchronous mode execution impossible Attempt was made to select the revision mode, shape development mode, or file loading mode during a synchronous mode. Character-string None Code None…

Okuma Alarm-B 2605 Tow-along tailstock no spec.

Okuma Alarm-B 2605 Tow-along tailstock no spec. VPTSP (System variable) is designated although the control has no tow-along tailstock specification. Probable Faulty Locations 1) Programming error Program Example: V1=VPTSP Measures…

Okuma Alarm-B 2606 READ/WRITE file open

Okuma Alarm-B 2606 READ/WRITE file open first (READ/WRITE) This alarm occurs in file operation using FOPENA/B or FWRITC command. Code 1->FOPENA/B was used to open two or more files. 2->FWRITC…

Okuma Alarm-B 2598 No Spec code. “Tool information management spec”

Okuma Alarm-B 2598 No Spec code. “Tool information management spec” Cutting operation ready command is instructed without “Tool information management spec” Object SYSTEM Code X 1:Cutting operation ready command is…

Okuma Alarm-B 2599 Command not possible while mounting LBB.

Okuma Alarm-B 2599 Command not possible while mounting LBB. The instruction that was not able to be executed while installing LBB was done. Object SYSTEM Code 1->It instructed in M13,…

Okuma Alarm-B 2602 SCHEDULE PROGRAM main program load

Okuma Alarm-B 2602 SCHEDULE PROGRAM main program load An error occurred when a main program was selected in schedule program. Object None Character-string None Code XXXX 5200:An attempt to select…