Okuma Alarms Errors
Okuma alarms and errors.
Okuma Alarm-B 2605 Tow-along tailstock no spec.
Okuma Alarm-B 2605 Tow-along tailstock no spec. VPTSP (System variable) is designated although the control has no tow-along tailstock specification. Probable Faulty Locations 1) Programming error Program Example: V1=VPTSP Measures…
Okuma Alarm-B 2606 READ/WRITE file open
Okuma Alarm-B 2606 READ/WRITE file open first (READ/WRITE) This alarm occurs in file operation using FOPENA/B or FWRITC command. Code 1->FOPENA/B was used to open two or more files. 2->FWRITC…
Okuma Alarm-B 2597 G15 command
Okuma Alarm-B 2597 G15 command Though it was not in transportation mode, G15-command has instructed. Code 1->Though it was not in transportation mode, G15-command has instructed. Probable Faulty Locations Program…
Okuma Alarm-B 2608 Mistake in ON command
Okuma Alarm-B 2608 Mistake in ON command The ON command value is larger than max number.
Okuma Alarm-B 2609 A-axis control no spec.
Okuma Alarm-B 2609 A-axis control no spec. The spindle table rotation command was performed in the machine was not A-axis specification.
Okuma Alarm-B 2610 Zero offset select inpossible
Okuma Alarm-B 2610 Zero offset select inpossible The Zero Offset Select command was performed in prohibition command practice.
Okuma Alarm-B 2607 Mistake in AP command
Okuma Alarm-B 2607 Mistake in AP command The AP command value is larger than point number of A-axis.
Okuma Alarm-B 2613 Mistake in MTM command
Okuma Alarm-B 2613 Mistake in MTM command A wrong tool number was specified with the MTM command. MTM:Tool preparation command,from sub-magazine to main-magazine (MTM=$$, where $$ is the tool No.)…
Okuma Alarm-B 2614 Mistake in MTS command
Okuma Alarm-B 2614 Mistake in MTS command A wrong tool number was specified with the MTS command. MTS:Tool preparation command,from main-magazine to sub-magazine (MTS=$$, where $$ is the tool No.)…
Okuma Alarm-B 2615 Mistake in MGS command
Okuma Alarm-B 2615 Mistake in MGS command MGS command is wrong. MGS:Sub-magazine index command (MGS=**,where ** is the sub-magazine pot No.) Code Specified magazine number
Okuma Alarm-B 2616 B-axis mode
Okuma Alarm-B 2616 B-axis mode They went along an inappropriate instruction in B axis mode. Or it was ordered lathe machining mode (G270), C-axis machining mode (G271) and Y-axis machining…
Okuma Alarm-B 2617 Zero setting condition
Okuma Alarm-B 2617 Zero setting condition Zero offset data could not be changed due to the setting for the system variable. Code X X = 1 -> An attempt was…
Okuma Alarm-B 2618 Workpiece detection sensor not ready
Okuma Alarm-B 2618 Workpiece detection sensor not ready Code 1->The work-piece detection sensor is not indexed, or the turret station set at the parameter as the station having a work…
Okuma Alarm-B 2611 Spindle fluctuation control no spec.
Okuma Alarm-B 2611 Spindle fluctuation control no spec. When the spindle fluctuation control specification is not selected,system variable command of spindle fluctuation control is designated. Object SYSTEM Code None Probable…
Okuma Alarm-B 2612 Mistake in TR command
Okuma Alarm-B 2612 Mistake in TR command Illigal TR command. Code 1->TR command was executed, when the coordinate system was selected G13. 2->TR command and T command were ordered at…
Okuma Alarm-B 2622 Unset system variable read
Okuma Alarm-B 2622 Unset system variable read When the optional parameter bit No.65 bit1 is “0”, VMPOX/VMPOZ are executed without memorized position.
Okuma Alarm-B 2619 Mistake in SW command
Okuma Alarm-B 2619 Mistake in SW command Illegal SW command Numerical value of SW command is not: 0
Okuma Alarm-B 2624 Tow-along steady rest type-B no spec
Okuma Alarm-B 2624 Tow-along steady rest type-B no spec G153 is designated although the control has no tow-along steady rest specification. Probable Faulty Locations Program error Program Example: N010 G153…
Okuma Alarm-B 2625 Tow-along steady rest movement condition
Okuma Alarm-B 2625 Tow-along steady rest movement condition G153 (tow-along steady rest positioning cycle) is designated in other than G13 (A saddle) mode. G153 is designated without a W command….
Okuma Alarm-B 2626 W-axis overlap
Okuma Alarm-B 2626 W-axis overlap The W-axis overlap command execute when the command designating conditions are not satisfied. They went along an inappropriate instruction in W-axis overlap mode. Object SYSTEM…
Okuma Alarm-B 2628 Mistake in TW command
Okuma Alarm-B 2628 Mistake in TW command Illegal TW command. In TW=** comand, tool offset number are larger than 32. (96 for 96-pair specification) Object SYSTEM Code Hexadecimal number of…
Okuma Alarm-B 2629 Mistake in FW command
Okuma Alarm-B 2629 Mistake in FW command Illegal FW command. Numerical value of an FW command is either negative or zero. Object SYSTEM Code 2->FW value is either negative or…
Okuma Alarm-B 2632 DNC-DT Program select
Okuma Alarm-B 2632 DNC-DT Program select An alarm occurred during program selection by DNC-DT. Index None Character-string None Code YY: YY application error NO. 800000XX: XX communicative error NO. FFFFFFFFF:…
Okuma Alarm-B 2633 DNC-DT Preload error
Okuma Alarm-B 2633 DNC-DT Preload error Buffering processing at the DNC-DT was abnormal. Index None Character-string None Code 100:Hardware error (hard disk, etc.) XXYYZZ XX= 6F->Insufficient buffer in TCP/IP driver…
Okuma Alarm-B 2623 B-axis no spec.
Okuma Alarm-B 2623 B-axis no spec. B-axis G code (G146/G147) is designated although the control has no B-axis specification. Object SYSTEM Probable Faulty Locations Program error Program Example: N010 G147…
Okuma Alarm-B 2631 DNC-DT Path name
Okuma Alarm-B 2631 DNC-DT Path name Program selection by DNC-DT failed because of faulty file name. The number of characters composed of device name, path name, and file name exceeds…
Okuma Alarm-B 2630 Mistake in SC command
Okuma Alarm-B 2630 Mistake in SC command Illegal SC command Numerical value of SC command is not: 0
Okuma Alarm-B 2634 DNC-DT Delete error
Okuma Alarm-B 2634 DNC-DT Delete error By delete automatic formatting of a schedule program, delete of file was not performed normally. Index None Character-string None Code FFFFFFFF: Without file,or a…
Okuma Alarm-B 2635 Y-axis mode
Okuma Alarm-B 2635 Y-axis mode The Tool radius compensation command (G41/G42) is instructed in Y-Z Plane (G19). Object Turret Character-string None Code XX XX=19:Y-Z Plane Probable Faulty Locations The programming…
Okuma Alarm-B 2637 No axis movement command
Okuma Alarm-B 2637 No axis movement command After Geometric transformation G137 commanded, the axis movement instruction is done in first X-Y block. After 3-D Coordinate conversion G303/G302 commanded, the axis…
Okuma Alarm-B 2643 READ/WRITE File open
Okuma Alarm-B 2643 READ/WRITE File open This alarm occurs in file operation using FOPENA/B or FWRITC command. Code 1->FOPENA/B was used to open two or more files. 2->FWRITC was used…
Okuma Alarm-B 2644 Unusable PRINT request
Okuma Alarm-B 2644 Unusable PRINT request A PRINT command was given during activation of READ/WRITE or GET/PUT function. Probable Faulty Locations A PRINT command was issued during activation of READ/WRITE…
Okuma Alarm-B 2645 YS-axis position
Okuma Alarm-B 2645 YS-axis position In the status that Y-axis-mode was OFF, YS-axis was not in the turning-position of SYSTEM-PARAMETER. And the programa was started in the status. Or, after…
Okuma Alarm-B 2646 SYSTEM VARIABLE C-axis separation
Okuma Alarm-B 2646 SYSTEM VARIABLE C-axis separation Ordered a system variable command for C-axis, when C-axis doesn’t connect. Object Turret Character None Code None Probable Faulty Locations Doesn’t connect C-axis….
Okuma Alarm-B 2648 MG tool ready cycle no spec.
Okuma Alarm-B 2648 MG tool ready cycle no spec. MG tool ready cycle command was issued at the machine without MG tool ready cycle specification. Object SYSTEM Probable Faulty Locations…