Okuma Alarm-B 2648 MG tool ready cycle no spec.
Okuma Alarm-B 2648 MG tool ready cycle no spec. MG tool ready cycle command was issued at the machine without MG tool ready cycle specification. Object SYSTEM Probable Faulty Locations…
Okuma Alarm-B 2639 Unable to issue C-axis command during helical cutting
Okuma Alarm-B 2639 Unable to issue C-axis command during helical cutting Ordered C-axis moving command when the machine is following conditions. Object Turret Character None Code X X=1:Ordered command without…
Okuma Alarm-B 2640 AC thread rotation count error
Okuma Alarm-B 2640 AC thread rotation count error Illegal S command on thread override mode. Numerical vaule of S command is not follow: 0 < S < Allowable revolution Object...
Okuma Alarm-B 2641 AC thread fluctuation control not possible
Okuma Alarm-B 2641 AC thread fluctuation control not possible Execute thread cycle when spinlde fluctuation and AC thread mode. Object Turret Probable Faulty Locations Thread cycle command on spinlde fluctuatuin…
Okuma Alarm-B 2649 SYSTEM VARIABLE Y-axis mode
Okuma Alarm-B 2649 SYSTEM VARIABLE Y-axis mode Ordered a system variable command for Y-axis without Y-axis mode. Object Turret Character None Code None Probable Faulty Locations Y-axis mode. Measures to…
Okuma Alarm-B 2650 SYSTEM VARIABLE B-axis mode
Okuma Alarm-B 2650 SYSTEM VARIABLE B-axis mode Ordered a system variable command without B-axis mode. Object Turret Character None Code None Probable Faulty Locations B-axis mode. Measures to Take Order…
Okuma Alarm-B 2651 C-axis multi rotation mode
Okuma Alarm-B 2651 C-axis multi rotation mode Specified C-axis multi rev operation was illegal. Object Axis name or none (spindle) Character-string None Code 1->C-axis multi rev instruction was executed while…
Okuma Alarm-B 2652 Mistake in HA command
Okuma Alarm-B 2652 Mistake in HA command Value of ‘HA’ command is over the range that be from -359.999 to 359.999. Code Hexadecimal of ‘HA’ command
Okuma Alarm-B 2662 NC TAILSTOCK no spec.
Okuma Alarm-B 2662 NC TAILSTOCK no spec. G195 is designated although the control has no NC tailstock specification. Concerning Sub spindle-tailstock Control specification, it instructed with the instruction prohibited. Code…
Okuma Alarm-B 2659 NC tailstock position error
Okuma Alarm-B 2659 NC tailstock position error Out advance of the NC tailstock Code 1->The current position(APA) is positioned at -side viewed from the sizing position area1. Or the torque…
Okuma Alarm-B 2654 Hob circular cutting command
Okuma Alarm-B 2654 Hob circular cutting command In the arc hob cutting commands, the designated arc either is in contact with or intersects the line (called the center line) passing…
Okuma Alarm-B 2655 Hob cutting command
Okuma Alarm-B 2655 Hob cutting command Spiral gear cutting mode command designated when turret was not Y-axis mode. The movement command designated expect for G00,G01,G02,G03 in the spiral gear cutting…
Okuma Alarm-B 2657 SYSTEM VARIABLE C-axis connect
Okuma Alarm-B 2657 SYSTEM VARIABLE C-axis connect Ordered a system variable command for spindle, with C-axis connection Object Turret Character None Code None Probable Faulty Locations C-axis connect. Measures to…
Okuma Alarm-B 2663 Turning cut condition interlock
Okuma Alarm-B 2663 Turning cut condition interlock A necessary condition is insufficient in case of the turning cut. Character-string None Code 1-> It tried to rotate the work spindle in…
Okuma Alarm-B 2667 X-axis mirror image coordinates selected
Okuma Alarm-B 2667 X-axis mirror image coordinates selected The axis movement instruction was executed in AUTO mode, while X-axis mirror image coordinate system was selected. Otherwise, C-axis connection instruction or…
Okuma Alarm-B 2677 Attachment change not possible
Okuma Alarm-B 2677 Attachment change not possible It instructed when it was not possible to instruct in attachment data exchange. (M798,M799,M1061) Object SYSTEM Code 1->There is no Attachment specification. 2->It…
Okuma Alarm-B 2678 SPM contour control not possible
Okuma Alarm-B 2678 SPM contour control not possible Super Precision Machining (SPM) control was attempted when execution of such control is inhibited. (Super Precision Machining (SPM) control = Hi-Cut Pro…
Okuma Alarm-B 2653 Mistake in MN command
Okuma Alarm-B 2653 Mistake in MN command Value of ‘MN’ command is over the range that be from 0.001 to 999.999. Code Hexadecimal of ‘MN’ command
Okuma Alarm-B 2668 X-axis mirror image coordinates impossible
Okuma Alarm-B 2668 X-axis mirror image coordinates impossible X-axis mirror image coordinate system was not able to be selected. Object SYSTEM Code 1-> X-axis mirror image coordinate instruction (G105) was…
Okuma Alarm-B 2671 C-axis sync control no spec.
Okuma Alarm-B 2671 C-axis sync control no spec. On the machine without C-axis sync control function, M888-M890 was issued. Object SYSTEM Character-string None Code None Probable Faulty Locations 1) Programming…
Okuma Alarm-B 2672 C-axis sync command format
Okuma Alarm-B 2672 C-axis sync command format Specified C-axis sync command was illegal. Object Axis name or none (spindle) Character-string None Code 1->Order besides M888 in the sync. side when…
Okuma Alarm-B 2674 Default status macro cannot be executed
Okuma Alarm-B 2674 Default status macro cannot be executed The Macro put into the initial condition (G194 command) were not able to be executed. Object SYSTEM Code 1->The G194 command…
Okuma Alarm-B 2675 Tool posture command error
Okuma Alarm-B 2675 Tool posture command error There is an error in the tool direction command. Object None Character-string None Code 1: It was specified an axis angle mode in…
Okuma Alarm-B 2676 Tool posture command angle conversion error
Okuma Alarm-B 2676 Tool posture command angle conversion error Conversion to the angle from the vector failed. Object None Character-string None Code 1: The N TRAVEL LIMIT is larger than…
Okuma Alarm-B 2684 MCS Rotary encoder 5 error
Okuma Alarm-B 2684 MCS Rotary encoder 5 error Illegal data was detected in Rotary encoder 5(Others). Object Axis Character-string None Probable Faulty Locations Rotary encoder 5(Others). Corrective Action Change Rotary…
Okuma Alarm-B 2690 MCS Rotary encoder 1 initialization failure
Okuma Alarm-B 2690 MCS Rotary encoder 1 initialization failure It failed in initialization of Rotary encoder 1. Object Axis Character-string None Code XXYYZZZZ Same with the alarm No. 0865 “MCS…
Okuma Alarm-B 2691 MCS Rotary encoder 1 error
Okuma Alarm-B 2691 MCS Rotary encoder 1 error Illegal data was detected in Rotary encoder 1. Object Axis Character-string None Code XXYYZZZZ XX= Rotary encoder status bit7 alarm bit6 communication…
Okuma Alarm-B 2679 Mistake in Q command
Okuma Alarm-B 2679 Mistake in Q command The G265 command (Super-NURBS control mode ON) block has a Q command (Program Filter value: Angle) of which value is out of the…
Okuma Alarm-B 2682 Magnetic encoder speed detection error
Okuma Alarm-B 2682 Magnetic encoder speed detection error The difference between speed feed back value and current frequency of Magnetic encoder was always observed, and there was a difference in…
Okuma Alarm-B 2683 MCS Rotary encoder 5 initialization failure
Okuma Alarm-B 2683 MCS Rotary encoder 5 initialization failure It failed in initialization of Rotary encoder 5(Others). Object Axis Character-string None Probable Faulty Locations Rotary encoder 5(Others). Corrective Action Change…
Okuma Alarm-B 2687 MCS Rotary encoder 3 initialization failure
Okuma Alarm-B 2687 MCS Rotary encoder 3 initialization failure It failed in initialization of Rotary encoder 3(HEIDENHAIN). Object Axis Character-string None Probable Faulty Locations Rotary encoder 3(HEIDENHAIN). Corrective Action Change…
Okuma Alarm-B 2688 MCS Rotary encoder 3 error
Okuma Alarm-B 2688 MCS Rotary encoder 3 error Illegal data was detected in Rotary encoder 3(HEIDENHAIN). Object Axis Character-string None Probable Faulty Locations Rotary encoder 3(HEIDENHAIN). Corrective Action Change Rotary…
Okuma Alarm-B 2689 MCS Rotary encoder 2 error
Okuma Alarm-B 2689 MCS Rotary encoder 2 error Illegal data was detected in Rotary encoder 2(INA-BEARING). Object Axis Character-string None Code XXXXYYYY XXXX= Content of illegal data 000A[HEX] : illegal…
Okuma Alarm-B 2693 MCS Linear scale 4 error
Okuma Alarm-B 2693 MCS Linear scale 4 error Illegal data was detected in Liner scale 4(Others). Object Axis Character-string None Probable Faulty Locations Linear scale 4(Others). Corrective Action Change Linear…
Okuma Alarm-B 2694 MCS Linear scale 3 initialization failure
Okuma Alarm-B 2694 MCS Linear scale 3 initialization failure It failed in initialization of Linear scale 3(HEIDENHAIN). Object Axis Character-string None Probable Faulty Locations Linear scale 3(HEIDENHAIN). Corrective Action Change…