Okuma Alarm-B 2942 Command impossible while running
Okuma Alarm-B 2942 Command impossible while running One word advance or one word return command, or program/sequence number selection command is given while the loader(robot) is operating. Code 1->One word…
Okuma Alarm-B 2943 Data file read
Okuma Alarm-B 2943 Data file read There is no V number command in the loader(robot) file which is going to be read into the loader memory. Object 0->Not related with…
Okuma Alarm-B 2944 Comment end code not found
Okuma Alarm-B 2944 Comment end code not found There is no comment end character “)” which corresponds to the comment start charactor “)”. Code 1->Comment in the program 2->Comment in…
Okuma Alarm-B 2945 Equal does not exist
Okuma Alarm-B 2945 Equal does not exist The register command on the left part is not follows by “=”. Probable Faulty Locations 1)Programming error
Okuma Alarm-B 2946 No spec.
Okuma Alarm-B 2946 No spec. A command related with the specification which is not supported is given. A hand operating command is given in the automatic or MDI mode while…
Okuma Alarm-B 2953 DIRECTION Torque limit
Okuma Alarm-B 2953 DIRECTION Torque limit Toruque limit, torque skip or torque limit check command is designated incorrectly. Code 1->No T* command in the G22,G23 or G29 block. 2->T* command…
Okuma Alarm-B 2948 DIRECTION Y
Okuma Alarm-B 2948 DIRECTION Y Y-axis command value is outside the range from -9999.99 to 9999.99. Code Y-axis command value Probable Faulty Locations 1)Program error 2)Operation error
Okuma Alarm-B 2949 DIRECTION Z
Okuma Alarm-B 2949 DIRECTION Z Z -axis command value is outside the range from -9999.99 to 9999.99. Code Z-axis command value Probable Faulty Locations 1)Program error 2)Operation error
Okuma Alarm-B 2950 DIRECTION D
Okuma Alarm-B 2950 DIRECTION D D command value for torque skip is outside the limit or below the positioning start point value. Code D command value Probable Faulty Locations Program…
Okuma Alarm-B 2951 DIRECTION L
Okuma Alarm-B 2951 DIRECTION L L command value for torque skip is outside the limit. Code L command value Probable Faulty Locations Program error
Okuma Alarm-B 2952 DIRECTION SU
Okuma Alarm-B 2952 DIRECTION SU SU command value is incorrect. Code 1->No SU command is designated in the G27 block. 2->SU command value is not 50
Okuma Alarm-B 2955 PROGRAM DIRECT Equal
Okuma Alarm-B 2955 PROGRAM DIRECT Equal Wrong usage of “=” symbol. Code XXYY(Factor classification code/ Factor parameter) Probable Faulty Locations 1)Program error 2)Operation error
Okuma Alarm-B 2956 Machine change M-code
Okuma Alarm-B 2956 Machine change M-code For the multiple NC lathe specification, an M code is given for the NC while the NC lathe change command is not given. Probable…
Okuma Alarm-B 2957 G22 feed
Okuma Alarm-B 2957 G22 feed The numerical value designated for F is “0”. Probable Faulty Locations Program error
Okuma Alarm-B 2941 SUB PROGRAM Buffer over
Okuma Alarm-B 2941 SUB PROGRAM Buffer over The loader(robot) program requested by the NC lathe or the one going to be selected uses more than 32 kinds of subprograms. Probable…
Okuma Alarm-B 2958 Main sequence
Okuma Alarm-B 2958 Main sequence The task has not been finished within the specified period. Probable Faulty Locations Bug
Okuma Alarm-B 2959 Barrier limit
Okuma Alarm-B 2959 Barrier limit The program which causes interference with the NC lathe or peripheral equipment has been read. Code The barrier number causing interference Probable Faulty Locations Program…
Okuma Alarm-B 2969 G23 FEED
Okuma Alarm-B 2969 G23 FEED Feed command F of G23 is 0.
Okuma Alarm-B 2970 DIRECTION X
Okuma Alarm-B 2970 DIRECTION X Commanded X-Position is Not within [-9999.99, 9999.99]. Code Commanded X-Position
Okuma Alarm-B 2954 PROGRAM DIRECT M-code
Okuma Alarm-B 2954 PROGRAM DIRECT M-code An M code not supported by the selected specification is designated. Code Designated M code Probable Faulty Locations 1)Program error 2)Operation error
Okuma Alarm-B 2966 M code time over
Okuma Alarm-B 2966 M code time over The answer to the specified M code failed to come ON within the time set at the parameter No. 88 (Y). Probable Faulty…
Okuma Alarm-B 2967 Cycle time over
Okuma Alarm-B 2967 Cycle time over After the start of loader program, the time set at the parameter No. 89 (Y) elapsed before reception of M02. Probable Faulty Locations 1)Time…
Okuma Alarm-B 2968 Program selection
Okuma Alarm-B 2968 Program selection When a program was selected by the external program selection function, the program number was not found. Or, program selection was attempted during loader operation….
Okuma Alarm-B 2960 User reserve code
Okuma Alarm-B 2960 User reserve code The alarm set for register No.98. This alarm occuers if the following program is executed. R98=****(**** is displayed in a code.) Code The code…
Okuma Alarm-B 2961 Calculation function no spec.
Okuma Alarm-B 2961 Calculation function no spec. The designated operation function is not supported. Code 1->SIN, COS, TAN, ATAN, SQRT, ABS, BIN, BCD, ROUND, FIX, DFUP 2->ATAN2, MOD Probable Faulty…
Okuma Alarm-B 2962 Subscript function no spec.
Okuma Alarm-B 2962 Subscript function no spec. An attempt is made to execute a subscript operation although the corresponding function is not supported. Code 1 Probable Faulty Locations Program error
Okuma Alarm-B 2979 DIRECTION C
Okuma Alarm-B 2979 DIRECTION C Command value of C is beyond the scope of-99999.99 to 99999.99. Code C command value Probable Faulty Locations Part program error Operation error
Okuma Alarm-B 2964 NC program selection
Okuma Alarm-B 2964 NC program selection When the NC program selection command is given to the NC lathe, the NC program number set for resister No.90(No.91 for the NC lathe…
Okuma Alarm-B 2965 EXPRESSION subscript
Okuma Alarm-B 2965 EXPRESSION subscript The variable name specified by IO read variable was not found. Character-string Variable name Probable Faulty Locations 1) Programming error for robot: The answer to…
Okuma Alarm-B 2971 DIRECTION I
Okuma Alarm-B 2971 DIRECTION I Under G15 (New Position) Command, Commanded I-Position is Not within [0, 9999.99]. Code Commanded I-Position, in Hexadecimal
Okuma Alarm-B 2972 DIRECTION J
Okuma Alarm-B 2972 DIRECTION J Under G15 (New Position) Command, Commanded J-Position is Not within [0, 9999.99]. Code Commanded J-Position, in Hexadecimal
Okuma Alarm-B 2976 Stopper position data illegal
Okuma Alarm-B 2976 Stopper position data illegal Stopper position data illegal within the Main spindle which it read from absolutely decoder. Code 1->Position data surpassed permissive scope. 2->Position data is…
Okuma Alarm-B 2977 Program selection unsuitable
Okuma Alarm-B 2977 Program selection unsuitable Program for R side was selection on the side of L and cycle start was performed. Or, program for L side was selection on…
Okuma Alarm-B 2978 DIRECTION V
Okuma Alarm-B 2978 DIRECTION V Directive value of V axis is beyond the scope of -9999.99 to 9999.99. Code V axis directive value
Okuma Alarm-B 2980 No decimal point
Okuma Alarm-B 2980 No decimal point There was not a decimal point on numeric data of command. Character string The address character that there is not the decimal point which…