Okuma Alarm-B 2975 PROGRAM DIRECT character string

Okuma Alarm-B 2975 PROGRAM DIRECT character string Setting of character-string for the user reserved alarm comment system variable is wrong. Object SYSTEM Code 1->No character-string set 2->Character-string length is longer…

Okuma Alarm-B 2976 Stopper position data illegal

Okuma Alarm-B 2976 Stopper position data illegal Stopper position data illegal within the Main spindle which it read from absolutely decoder. Code 1->Position data surpassed permissive scope. 2->Position data is…

Okuma Alarm-B 2977 Program selection unsuitable

Okuma Alarm-B 2977 Program selection unsuitable Program for R side was selection on the side of L and cycle start was performed. Or, program for L side was selection on…

Okuma Alarm-B 2978 DIRECTION V

Okuma Alarm-B 2978 DIRECTION V Directive value of V axis is beyond the scope of -9999.99 to 9999.99. Code V axis directive value

Okuma Alarm-B 2981 DIRECTION Q

Okuma Alarm-B 2981 DIRECTION Q Q command of G15 order is beyond the range.(Q-range is from 0 to 99999.999) Code Q-command Measures to Take Review the value of Q-command.

Okuma Alarm-B 2572 Mistake in RC command

Okuma Alarm-B 2572 Mistake in RC command RC command value is out of the range from -999 to 999 . Code RC command value in hexadecimal

Okuma Alarm-B 2563 Mistake in TE command

Okuma Alarm-B 2563 Mistake in TE command TE-command is wrong. TE-command instructs the continuing turret-number by the order of rise. ex)The command between T2 and T3 TE=23 Object SYSTEM Code…

Okuma Alarm-B 2298 UGC DEF syntax

Okuma Alarm-B 2298 UGC DEF syntax Illegal registration declare command designated Code User graphic internal code Probable Faulty Locations Character-string:designated in the DEF statement in the user graphic command. Program…

Okuma Alarm-B 2296 UGC No program end code

Okuma Alarm-B 2296 UGC No program end code End of program code is read in the conversion process of the user graphic command characters. Code 1->When converting user graphic command…

Okuma Alarm-B 2297 UGC DELETE syntax

Okuma Alarm-B 2297 UGC DELETE syntax Illegal delete command designated Code User graphic internal code Probable Faulty Locations Character-string:designated in the DELETE statement in the user graphic command. Program Example:DELETE…

Okuma Alarm-B 2294 Special G-code table

Okuma Alarm-B 2294 Special G-code table The internal constant table determined by the special G code is incorrect. (This alarm does not occur usually.) Object SYSTEM Code Hexadecimal number of…

Okuma Alarm-B 2295 STM time over

Okuma Alarm-B 2295 STM time over The S, T, or M function execution cycle time exceeds the time preset with a parameter. Parameter OPTIONAL PARAMETER (CYCLE TIME OVER CHECK) STM…

Okuma Alarm-B 2293 MDI special G-code

Okuma Alarm-B 2293 MDI special G-code G code not executable in the MDI mode is designated. Object SYSTEM Code 1->G223 MODIN and/or G224 MODOUT statement is designated. 80->G80, G81, or…

Okuma Alarm-B 2292 Restart failure

Okuma Alarm-B 2292 Restart failure Probable Faulty Locations Improper Restart Command: Most likely; Start Key is pressed, before Sequence Return is completed. Code 1->2-Saddle Lathe: Start Key is pressed; after…

Okuma Alarm-B 2300 UGC TIF syntax

Okuma Alarm-B 2300 UGC TIF syntax Illegal standard procedure statement (TIF statement) designated TIF: Automatically generates tool interference check data based on the tool shape. TIF [designation of tool interference…

Okuma Alarm-B 2306 UGC Illegal command

Okuma Alarm-B 2306 UGC Illegal command Illegal character-string designated Code Hexadecimal number of ASCII, or user graphic internal code Probable Faulty Locations User graphic command string Program Example: DEF WORK…

Okuma Alarm-B 2291 Main sequence error

Okuma Alarm-B 2291 Main sequence error Error (TRAP #4) in main sequence. Usually, an error does not occur within a main sequence. Object SYSTEM Code 1

Okuma Alarm-B 2301 UGC No shape entry

Okuma Alarm-B 2301 UGC No shape entry No user graphic command to be registered. Code 1->There is no user graphic command between the registration declaration statement and the end declaration…

Okuma Alarm-B 2302 UGC Illegal numerical data

Okuma Alarm-B 2302 UGC Illegal numerical data Illegal numerical data input Code 5Number of digits overflow Probable Faulty Locations Numerical data in the user graphic command Program Example:DEF WORK PS…

Okuma Alarm-B 2303 UGC Illegal character

Okuma Alarm-B 2303 UGC Illegal character Illegal code not applicable to operator code designated Code 1->Hexadecimal number of ASCII Probable Faulty Locations User graphic command string Program Example:DEF WORK PS…

Okuma Alarm-B 2304 UGC User variable

Okuma Alarm-B 2304 UGC User variable Illegal user variable designated Code 0->No user variable number entry 1->Entry of a number following user variable number 0 2->Number of digits overflow in…

Okuma Alarm-B 2305 UGC System variable

Okuma Alarm-B 2305 UGC System variable Illegal system variable designated Code 0->No system variable number entry 1->Entry of a number following system variable number 2->Number of digits overflow in designating…

Okuma Alarm-B 2307 UGC Program factor over

Okuma Alarm-B 2307 UGC Program factor over Overflow of factor code stack or factor data stack Code 1->Factor code stack overflow at character-string conversion 2->Factor data stack overflow at character-string…

Okuma Alarm-B 2308 UGC Coordinate data

Okuma Alarm-B 2308 UGC Coordinate data Mismatch of the numbers of the left and right brackets, illegal factor code, inconsistency of the number of command coordinates Object SYSTEM Code 1->Mismatch…

Okuma Alarm-B 2309 UGC END syntax

Okuma Alarm-B 2309 UGC END syntax Illegal end declaration statement Object SYSTEM Code 1->LF for declaring END is not specified. Probable Faulty Locations END statement in the user graphic command…

Okuma Alarm-B 2310 UGC Command over

Okuma Alarm-B 2310 UGC Command over Overflow of user graphic command stack area Code 1->An overflow occurs in the temporary storage area for user graphic command string. Probable Faulty Locations…

Okuma Alarm-B 2311 UGC Command format

Okuma Alarm-B 2311 UGC Command format Syntax error with: POINT statement, VIEW statement, WINDOW statement, LINE statement, CIRCLE statement, PAINT statement, PAINTI statement, PAINTS statement, PAINTP statement, CALL statement, PLAIN…

Okuma Alarm-B 2314 UGC Figure entry area over

Okuma Alarm-B 2314 UGC Figure entry area over The total of previously registered area and the area registered presently exceeds the allowable value of the shape registration area. Code 1->No…

Okuma Alarm-B 2315 UGC Unable to delete

Okuma Alarm-B 2315 UGC Unable to delete No user graphic command string to be deleted. Code 1User graphic command to be deleted is not registered. Probable Faulty Locations DELETE statement…

Okuma Alarm-B 2316 READ/WRITE No spec

Okuma Alarm-B 2316 READ/WRITE No spec An attempt to execute the READ/WRITE command although the READ/WRITE specification is not available. Object SYSTEM Probable Faulty Locations Program error Measures to Take…

Okuma Alarm-B 2317 READ/WRITE Buffer over

Okuma Alarm-B 2317 READ/WRITE Buffer over Data size exceeds 160 bytes when READ/WRITE command is executed. Object SYSTEM Code 1->Alarm during execution of READ command 2->Alarm during execution of WRITE…

Okuma Alarm-B 2318 READ/WRITE Device No.

Okuma Alarm-B 2318 READ/WRITE Device No. Device number in a READ/WRITE command is wrong. Object SYSTEM Code 1->Device is specified by other than a number. 2->Device number is other than…

Okuma Alarm-B 2319 READ/WRITE Data

Okuma Alarm-B 2319 READ/WRITE Data Data in a READ/WRITE command is wrong. Object SYSTEM Code 1->Parity error in READ operation 2->Transmission end code in WRITE data Probable Faulty Locations Hardware…

Okuma Alarm-B 2312 UGC Additional parameter

Okuma Alarm-B 2312 UGC Additional parameter Illegal additional parameter programmed Code 1->Illegal circle rotation direction (other than omission, L and R) Illegal triangle angle (other than omission, 0, 1 and…

Okuma Alarm-B 2313 UGC Expression

Okuma Alarm-B 2313 UGC Expression Expression syntax error Code 1->More than one solution 2->Program end code in expression 3->Operand stack area over 4->Mismatch between the numbers of operands 5->Operand classification…