Okuma Alarms Errors

Okuma alarms and errors.

Okuma Alarm-B 2320 READ communication error

Okuma Alarm-B 2320 READ communication error An error during communications Object SYSTEM Character-string Data number involved in error Code Status code at an occurrence of error Probable Faulty Locations Varies…

Okuma Alarm-B 2321 WRITE communication error

Okuma Alarm-B 2321 WRITE communication error An error during communications Object SYSTEM Character-string Data number involved in error Code Status code at an occurrence of error Probable Faulty Locations Varies…

Okuma Alarm-B 2326 GET Numerical data

Okuma Alarm-B 2326 GET Numerical data Wrong numerical data during the execution of the GET command Object SYSTEM Code 1->Characters other than numbers and space are contained. 2->More than one…

Okuma Alarm-B 2327 Calculation function no spec.

Okuma Alarm-B 2327 Calculation function no spec. A command calling for calculation is designated although the control has no calculation specification (user task 2). The following command is designated: EOR,…

Okuma Alarm-B 2328 Sub-program no spec.

Okuma Alarm-B 2328 Sub-program no spec. Subprogram is programmed although the control has no subprogram specification (user task 2). Probable Faulty Locations Program error Program Example:CALL OSUB Measures to Take…

Okuma Alarm-B 2329 Sub-spindle interference distance

Okuma Alarm-B 2329 Sub-spindle interference distance The issued command requires the sub spindle headstock (W-axis) and B-turret (ZA-axis) to come closer beyond the interference distance specified by the parameter. Code…

Okuma Alarm-B 2325 GET/PUT Variable designation

Okuma Alarm-B 2325 GET/PUT Variable designation Improper element in the data when a command is executed. Object SYSTEM Code XYY X: 1->During GET command execution 2->During PUT command execution YY:Hexadecimal…

Okuma Alarm-B 2331 Multiple machining no spec.

Okuma Alarm-B 2331 Multiple machining no spec. A multi-machining M code (C-axis, M-tool) is designated for other than multi-machining models. Object SYSTEM Code XX:Hexadecimal number of designated M code Probable…

Okuma Alarm-B 2332 Sub-spindle no spec.

Okuma Alarm-B 2332 Sub-spindle no spec. G239 (blank copy) is designated though the sub-spindle specification is not provided. Concerning Sub spindle-tailstock Control specification, it instructed with the instruction prohibited. Probable…

Okuma Alarm-B 2322 GET/PUT No spec.

Okuma Alarm-B 2322 GET/PUT No spec. An attempt to execute the GET/PUT command although the GET/PUT specification is not supported. Probable Faulty Locations Program error Measures to Take Delete the…

Okuma Alarm-B 2323 GET/PUT Buffer over

Okuma Alarm-B 2323 GET/PUT Buffer over The number of data sets is too much or too less for executing the data. Object SYSTEM Code 1->With the GET command, the number…

Okuma Alarm-B 2324 GET/PUT Number of digits

Okuma Alarm-B 2324 GET/PUT Number of digits Specification of the number of figures is wrong when a command is executed. Object SYSTEM Code 1->During GET command execution 2->During PUT command…

Okuma Alarm-B 2330 Input/output variable no spec.

Okuma Alarm-B 2330 Input/output variable no spec. I/O variables are designated although the control has no I/O variable specification (user task 2). Probable Faulty Locations Program error Program Example:N010 VDOUT[1]…

Okuma Alarm-B 2339 Load monitor no spec.

Okuma Alarm-B 2339 Load monitor no spec. When the load monitor specification is not selected, System-variable of Load monitor or CLEAR command is designated. Object SYSTEM Code None ->On the…

Okuma Alarm-B 2340 Thread phase matching no spec.

Okuma Alarm-B 2340 Thread phase matching no spec. System variable for thread phase correction (VTHRX or VTHRZ) is designated although the thread phase correction specification is not supported. Or,it instructed…

Okuma Alarm-B 2344 Tool retract interrupt enable com.

Okuma Alarm-B 2344 Tool retract interrupt enable com. A wrong command is contained in the tool retraction interruption enabling command (EIN). Object SYSTEM Code 1->The EIN command is already designated….

Okuma Alarm-B 2345 Tool retract interrupt disable com.

Okuma Alarm-B 2345 Tool retract interrupt disable com. A wrong command is contained in the tool retraction interruption disabling command (DIN). Object SYSTEM Code 1->DIN command was specified before EIN…

Okuma Alarm-B 2334 In-process gauging no spec.

Okuma Alarm-B 2334 In-process gauging no spec. In-process work gauging variables are designated or the gauging cycle is programmed although the control has no in-process gauging specification. Object SYSTEM Code…

Okuma Alarm-B 2335 Post-process gauging no spec.

Okuma Alarm-B 2335 Post-process gauging no spec. Post-process work gauging variables are designated although the control has no post-process gauging specification. Object SYSTEM Code 1->Post-process gauging variables are designated in…

Okuma Alarm-B 2336 Animation no spec.

Okuma Alarm-B 2336 Animation no spec. An attempt to execute graphic command is made although the graphic specification is not supported. Object SYSTEM Probable Faulty Locations Program error Program Example:…

Okuma Alarm-B 2337 Graphic backup data file write failure

Okuma Alarm-B 2337 Graphic backup data file write failure Failure in writing of the graphic PBU file by the SAVE command. Probable Faulty Locations Memory Measures to Take Replace memory…

Okuma Alarm-B 2338 Spindle orientation no spec.

Okuma Alarm-B 2338 Spindle orientation no spec. Spindle orientation M code (M19) is designated although the control has no spindle orientation specification. Object SYSTEM Probable Faulty Locations Program error Program…

Okuma Alarm-B 2343 Tool retract no spec.

Okuma Alarm-B 2343 Tool retract no spec. The tool retraction command is designated although the control does not support the tool retraction specification. Object SYSTEM Code 1->The EIN, DIN, or…

Okuma Alarm-B 2348 ROBOT program name

Okuma Alarm-B 2348 ROBOT program name No robot program name is designated following G227. Object SYSTEM Code 1 Probable Faulty Locations Program error Program Example:ROBOT Measures to Take Designate the…

Okuma Alarm-B 2349 LOADER no spec.

Okuma Alarm-B 2349 LOADER no spec. A loader program is called for the machine not equipped with a loader. Code 1->Loader program was called by a Loader good for nothing…

Okuma Alarm-B 2350 LOADER program name

Okuma Alarm-B 2350 LOADER program name No loader program name is designated when loading command is provided. Object SYSTEM Code 1 Probable Faulty Locations Program error Program Example:N010 LOADER Measures…

Okuma Alarm-B 2351 Coupling device program select no spec.

Okuma Alarm-B 2351 Coupling device program select no spec. An attempt was made to select (MHPS) the program for an external device although the coupled device program selection specification is…

Okuma Alarm-B 2341 Circular thread cutting no spec.

Okuma Alarm-B 2341 Circular thread cutting no spec. The arc thread cutting command (G112, G113) is designated while the arc thread cutting specification is not supported. Object SYSTEM Probable Faulty…

Okuma Alarm-B 2360 NOSE-R COMP. NOSE-R > circle-R

Okuma Alarm-B 2360 NOSE-R COMP. NOSE-R > circle-R Point of intersection cannot be calculated since the radius of the designated arc is smaller than nose radius. Object SYSTEM Code 1->When…

Okuma Alarm-B 2361 NOSE-R COMP. Calculation

Okuma Alarm-B 2361 NOSE-R COMP. Calculation Error in floating-point calculation for nose radius compensation. Object SYSTEM Code XYY YY: bit0->Overflow in converting into integer bit1->Exponential underflow bit2->Exponential overflow bit3->Calculation of…

Okuma Alarm-B 2362 NOSE-R COMP. Cancel G00 G01

Okuma Alarm-B 2362 NOSE-R COMP. Cancel G00 G01 Code G40 canceling tool nose radius compensation mode is designated in other than the G00 or G01 mode. Object SYSTEM Code Program…

Okuma Alarm-B 2346 Tool retract interrupt return com.

Okuma Alarm-B 2346 Tool retract interrupt return com. The interruption return command (RTI) was issued when the tool retract interruption was not activated. Or, when it is under-cases, RTI-command was…

Okuma Alarm-B 2347 ROBOT no spec.

Okuma Alarm-B 2347 ROBOT no spec. G227 (robot request command) is designated although the control has no robot specification. Probable Faulty Locations Program error Program Example:ROBOT O100 Measures to Take…

Okuma Alarm-B 2366 TOOL RADIUS COMP. No spec.

Okuma Alarm-B 2366 TOOL RADIUS COMP. No spec. The cutter radius compensation ON command* is designated for the control not equipped with the cutter radius compensation function. * Compensation ON…

Okuma Alarm-B 2367 TOOL RADIUS COMP. NOSE-R comp. surface change

Okuma Alarm-B 2367 TOOL RADIUS COMP. NOSE-R comp. surface change The designated plane for the cutter radius compensation or nose R compensation is changed during the compensation mode is active.Before…