Okuma Alarms Errors

Okuma alarms and errors.

Okuma Alarm-B 2399 MULTI CYCLE L illegal order

Okuma Alarm-B 2399 MULTI CYCLE L illegal order In G73 and G74 grooving cycle, numerical value of L command is not: 0 < L

Okuma Alarm-B 2393 MULTI CYCLE D illegal order

Okuma Alarm-B 2393 MULTI CYCLE D illegal order In G71, G72, G73 or G74 mode, no D command is designated or numerical value of D command is not: 0 <...

Okuma Alarm-B 2394 MULTI CYCLE F illegal order

Okuma Alarm-B 2394 MULTI CYCLE F illegal order In G71, G72, G73 or G74 mode, no F(thread pitch) command is designated or numerical value of F command is not: 0…

Okuma Alarm-B 2395 MULTI CYCLE H illegal order

Okuma Alarm-B 2395 MULTI CYCLE H illegal order In G71 and G72 thread cutting mode, no H(difference between major and minor diameters) (diameter command) command is designated or numerical value…

Okuma Alarm-B 2396 MULTI CYCLE H-U(W) < D (M73)

Okuma Alarm-B 2396 MULTI CYCLE H-U(W) < D (M73) In M73 of G71 or G72 thread cutting mode, the value "H-U (W)" is smaller than D. G71: Compound thread cutting...

Okuma Alarm-B 2397 MULTI CYCLE I,K over

Okuma Alarm-B 2397 MULTI CYCLE I,K over In the G73 and G74 grooving cycle, the parameter of I or K is greater than the allowable value causing negative groove depth….

Okuma Alarm-B 2398 MULTI CYCLE I,K illegal order

Okuma Alarm-B 2398 MULTI CYCLE I,K illegal order In the G71 mode, K command is designated, both A and I commands are designated, or neither A nor I command is…

Okuma Alarm-B 2400 MULTI CYCLE Entry in LAP

Okuma Alarm-B 2400 MULTI CYCLE Entry in LAP During LAP control, multi cycle command is designated. Object SYSTEM Probable Faulty Locations Program error Program Example: NLAP1 G81 : N010 G73…

Okuma Alarm-B 2401 MULTI CYCLE U(W) illegal order

Okuma Alarm-B 2401 MULTI CYCLE U(W) illegal order In G71 thread cutting cycle, either W command is designated or the numerical value of U command is not: 0

Okuma Alarm-B 2402 MULTI CYCLE U(W) > H

Okuma Alarm-B 2402 MULTI CYCLE U(W) > H In G71 or G72 thread cutting cycle, designated finish allowance U or W is larger than the thread height H. G71: Compound…

Okuma Alarm-B 2409 TOOL LIFE CONTROL no spec.

Okuma Alarm-B 2409 TOOL LIFE CONTROL no spec. Tool life management variables are designated although the control has no tool life management specification. Tool group TG and tool offset group…

Okuma Alarm-B 2410 Tool life management No spare tool

Okuma Alarm-B 2410 Tool life management No spare tool There is no spare tool in the commanded tool group. Object SYSTEM Code Hexadecimal number of the tool group having no…

Okuma Alarm-B 2416 MULTI-MACHINING CYCLE C

Okuma Alarm-B 2416 MULTI-MACHINING CYCLE C Programmed C value is not: -360-deg < C < 360-deg. Object SYSTEM Code Hexadecimal number of designated C value Probable Faulty Locations Faulty program...

Okuma Alarm-B 2417 MULTI-MACHINING CYCLE I,K

Okuma Alarm-B 2417 MULTI-MACHINING CYCLE I,K In G181 through G184 and G189 mode cycle, both I and K or neither I nor K is designated. (I,K shift amount) In G181…

Okuma Alarm-B 2418 MULTI-MACHINING CYCLE Q

Okuma Alarm-B 2418 MULTI-MACHINING CYCLE Q Designated Q value is not: 1

Okuma Alarm-B 2403 MULTI CYCLE X,Z illegal order

Okuma Alarm-B 2403 MULTI CYCLE X,Z illegal order In G71, G72, G73 or G74 mode, either X or Z command is not designated, or the value of them is not:…

Okuma Alarm-B 2419 MULTI-MACHINING CYCLE F

Okuma Alarm-B 2419 MULTI-MACHINING CYCLE F Designated F(cutting feedrate) value is either 0 or negative. E command value designated with G190 or G192 is either 0 or negative. No F…

Okuma Alarm-B 2404 MULTI CYCLE Angle

Okuma Alarm-B 2404 MULTI CYCLE Angle In the G71, G72 thread cutting cycle, A(taper angle) command is illegal and floating point of thread radius difference cannot be calculated. G71: Compound…

Okuma Alarm-B 2420 MULTI-MACHINING CYCLE L

Okuma Alarm-B 2420 MULTI-MACHINING CYCLE L Designated L value is not: 0 < L LA different processing pattern instruction was done at the synchronization tap cycle of a continuous block....

Okuma Alarm-B 2405 MULTI CYCLE Tool offset

Okuma Alarm-B 2405 MULTI CYCLE Tool offset In the G73, G74 grooving cycle, tool offset value specified in the program differs from the designated shift direction. G73: Compound grooving cycle…

Okuma Alarm-B 2406 MULTI CYCLE Cycle start point

Okuma Alarm-B 2406 MULTI CYCLE Cycle start point In the G71, G72 thread cutting cycle, H command is too large and the reference point of thread cutting is not located…

Okuma Alarm-B 2407 MULTI CYCLE Entry in NOSE-R comp.

Okuma Alarm-B 2407 MULTI CYCLE Entry in NOSE-R comp. During tool nose radius compensation mode, compound fixed cycle is designated. G41, G42: Tool nose radius compensation to the left, right…

Okuma Alarm-B 2408 MULTI CYCLE Width

Okuma Alarm-B 2408 MULTI CYCLE Width In the G73, G74 grooving cycle, the tool width calculated from the tool offset value is larger than the groove width. G73: Compound grooving…

Okuma Alarm-B 2411 TOOL LIFE CONTROL tool group

Okuma Alarm-B 2411 TOOL LIFE CONTROL tool group Numerical value of tool group command TG is: TG < 1 or TG > 12 For the ATC specification, Indexing a Tool…

Okuma Alarm-B 2412 TOOL LIFE CONTROL no T-entry

Okuma Alarm-B 2412 TOOL LIFE CONTROL no T-entry Tools are not registered in the designated tool group. Object SYSTEM Code FFFFFFFF Probable Faulty Locations Faulty program or setting error of…

Okuma Alarm-B 2413 TOOL LIFE CONTROL tool offset group

Okuma Alarm-B 2413 TOOL LIFE CONTROL tool offset group Illegal tool offset group number is designated. Object SYSTEM Code Hexadecimal number of the designated OG Probable Faulty Locations Program error…

Okuma Alarm-B 2414 TOOL LIFE CONTROL no T-offset

Okuma Alarm-B 2414 TOOL LIFE CONTROL no T-offset Tool offset number is not registered for the designated tool offset group. Object SYSTEM Code FFFFFFFF Probable Faulty Locations Faulty program or…

Okuma Alarm-B 2415 MULTI-MACHINING CYCLE No spec.

Okuma Alarm-B 2415 MULTI-MACHINING CYCLE No spec. G code calling fixed cycle for multi-machining model is designated for a lathe without multi-machining function. Object SYSTEM Code 1 Probable Faulty Locations…

Okuma Alarm-B 2421 MULTI-MACHINING CYCLE D

Okuma Alarm-B 2421 MULTI-MACHINING CYCLE D No D command Designated D value is not: 0 < D No D command Others:Hexadecimal number of designated D value Probable Faulty Locations Faulty...

Okuma Alarm-B 2422 MULTI-MACHINING CYCLE X,Z

Okuma Alarm-B 2422 MULTI-MACHINING CYCLE X,Z In the block containing G185 through G188, either X or Z is not designated. Or, numerical value of X and Z is not: -99999.999…

Okuma Alarm-B 2423 MULTI-MACHINING CYCLE SA

Okuma Alarm-B 2423 MULTI-MACHINING CYCLE SA Designated SA value is not: 0 < SA No SA command Others:Hexadecimal number of designated SA value Probable Faulty Locations Faulty program (compound fixed...

Okuma Alarm-B 2431 ATC syntax

Okuma Alarm-B 2431 ATC syntax On the turret without ATC function, an ATC related command was issued. T, TC, and TL commands are issued at the same time. TC: Turret…

Okuma Alarm-B 2432 ATC TC

Okuma Alarm-B 2432 ATC TC A nonexistent turret number is specified with TC command. TC: Turret index command to ATC position (TC = ##, where ## is the turret No.)…

Okuma Alarm-B 2438 Unable to M06/M228 command

Okuma Alarm-B 2438 Unable to M06/M228 command Specified M06,M228,or MG command was illegal. (M06 is used by M321 command of ATC macro command.) M06:Tool change command M228:ATC next tool return…

Okuma Alarm-B 2440 Y-axis no spec.

Okuma Alarm-B 2440 Y-axis no spec. Order in relation to Y-axis was performed in the machine which was not Y-axis specification. Object SYSTEM Probable Faulty Locations 1)Program error Program referred…