Okuma Alarms Errors

Okuma alarms and errors.

Okuma Alarm-B 2530 Machining process instruction no.

Okuma Alarm-B 2530 Machining process instruction no. Machining process instruction number (VWORK) from loader is the outside of range (VWORK99). Or, at the machining process instruction number which differed from…

Okuma Alarm-B 2531 Mirror turning mode

Okuma Alarm-B 2531 Mirror turning mode They went a condition along ON/OFF order of mirror turning mode by the condition which is not satisfied. Or, they went along the order…

Okuma Alarm-B 2532 System variable set condition error

Okuma Alarm-B 2532 System variable set condition error Conditions for setting the system variables are not met. Concerning Sub spindle-tailstock Control specification, it instructed with the instruction prohibited. Index None…

Okuma Alarm-B 2533 Steady rest over interference pos.

Okuma Alarm-B 2533 Steady rest over interference pos. Command for Steady-rests, Tail stock or W-axis to exceed the interference position. Object Axis Character-string None Code 1-> Right steady-rests interference area…

Okuma Alarm-B 2534 LBB turret rotation impossible

Okuma Alarm-B 2534 LBB turret rotation impossible It instructed when it was not possible to instruct in LBB turn. (G269) Object SYSTEM Code 1->There is no long bore bar specification….

Okuma Alarm-B 2538 Incorrect system variable

Okuma Alarm-B 2538 Incorrect system variable The instructed the system variable cannot be used. Object SYSTEM Code None Character-string Name of system variable

Okuma Alarm-B 2539 Mistake in B command

Okuma Alarm-B 2539 Mistake in B command B command is incorrect. The B command value specified together with G127 command is outside the setting range from -359.999 to 359.999. Object…

Okuma Alarm-B 2542 Feed axis retract function command

Okuma Alarm-B 2542 Feed axis retract function command Feed axis retract function command is incorrect. Object None Character-string None Code X 1->RT command value is out of the range from…

Okuma Alarm-B 2536 Coordinate movement rotation copy

Okuma Alarm-B 2536 Coordinate movement rotation copy G11/G10/COPY/COPE command is wrong. Object SYSTEM Code 1->G11/G10/COPY/COPE command is designated though the Coordinates movement rotation copy specification is not provided. 2->It instructed in…

Okuma Alarm-B 2537 SLANT PROCESS MODE

Okuma Alarm-B 2537 SLANT PROCESS MODE The slant process mode IN/OUT command(G127/G126) was executed though the required conditions were not satisfied. Or, a prohibited command was executed in the slant…

Okuma Alarm-B 2541 PROGRAM PRINT command

Okuma Alarm-B 2541 PROGRAM PRINT command Concerning a format of the following print command, it ordered another except for a comment sentence to an identical block. PRINT number = systematic…

Okuma Alarm-B 2562 Tool posture fluctuation reduction

Okuma Alarm-B 2562 Tool posture fluctuation reduction Tool posture fluctuation reduction is wrong. Object None Character-string None Code 1->It instructed in other G, M code, and the address character at…

Okuma Alarm-B 2543 Turret index error position

Okuma Alarm-B 2543 Turret index error position Axis feed command was issued in turret index error position. Object SYSTEM Code None Measures to Take 1)The turret is moved to X-axis…

Okuma Alarm-B 2544 TOOL-ID TOOL DATA

Okuma Alarm-B 2544 TOOL-ID TOOL DATA Concerning TOOL-ID specification, when it read and wrote tool data of every kind by the System Variable, since tool data had not been set…

Okuma Alarm-B 2545 MULTI-MACHINING CYCLE LD

Okuma Alarm-B 2545 MULTI-MACHINING CYCLE LD Designated LD value is not: 0 < LD LDA different processing pattern instruction was done at the synchronization tap cycle of a continuous block....

Okuma Alarm-B 2546 MULTI-MACHINING CYCLE LK

Okuma Alarm-B 2546 MULTI-MACHINING CYCLE LK Designated LK value is not: 0 < LK

Okuma Alarm-B 2547 No decimal point

Okuma Alarm-B 2547 No decimal point No decimal point on commanded numeric data. Character string The address character that there is not the decimal point which it detected at first….

Okuma Alarm-B 2548 X-, Z-axis synchronized feed mode

Okuma Alarm-B 2548 X-, Z-axis synchronized feed mode It performed X-Z both axis synchronaized feed mode command by the condition that a receipt valid condition has not formed. Or, it…

Okuma Alarm-B 2549 Tool no. mismatch after ATC sequence restart

Okuma Alarm-B 2549 Tool no. mismatch after ATC sequence restart By a restart function, when it returned a sequence, it was about to return a sequence the program which TL…

Okuma Alarm-B 2550 Home position no spec.

Okuma Alarm-B 2550 Home position no spec. Though CNC has no “Home position” specification,VHPPX or VHPPZ(home position system variable) is designated. Object SYSTEM Probable Faulty Locations 1) Though CNC has…

Okuma Alarm-B 2551 External home position command

Okuma Alarm-B 2551 External home position command Illegal condition occurred during execution of external home position command Object SYSTEM Code 1->In execution of external home position command, CON value of…

Okuma Alarm-B 2552 Barrier area

Okuma Alarm-B 2552 Barrier area Designated axis command is to enter inside of barrier area. Code None->The axis command is located inside of barrier area by axis movement of X-Y…

Okuma Alarm-B 2555 Linear guide cover interference area command

Okuma Alarm-B 2555 Linear guide cover interference area command It ordered in the linear guide cover interference area. Object AXIS, SYSTEM Code None Probable Faulty Locations It ordered in the…

Okuma Alarm-B 2557 Illegal steady rest command

Okuma Alarm-B 2557 Illegal steady rest command The numerical value is not between from -99999.999 to 99999.999. or the incremental word is not between from -99999.999 to 99999.999 when converted…

Okuma Alarm-B 2558 Turning position selection

Okuma Alarm-B 2558 Turning position selection In a MacTurn sub spindle specification, they went along selection command of upper position / lower position of YS axis turning position in Y-axis…

Okuma Alarm-B 2559 Attachment rotation not possible

Okuma Alarm-B 2559 Attachment rotation not possible It instructed when it was not possible to instruct in attachment turning command. Object SYSTEM Code 1->There is no Attachment specification or nor…

Okuma Alarm-B 2561 Illegal system command variable

Okuma Alarm-B 2561 Illegal system command variable Tool offset system var., Nose-R systme var. was issued Tool offset position select system var., Tool offset auto calculation pattern system var. same…

Okuma Alarm-B 2299 UGC TIP syntax

Okuma Alarm-B 2299 UGC TIP syntax Illegal standard procedure statement (TIP statement) designated TIP: Procedure statement for registering the tip shape Code User graphic internal code Probable Faulty Locations TIP…

Okuma Alarm-B 2290 Program name not selected

Okuma Alarm-B 2290 Program name not selected Program name is incorrectly designated. The program name* differing from the one presently executed is designated. * Command O**** is executed. Object SYSTEM…

Okuma Alarm-B 2237 BRANCH (IF,GOTO) sequence name

Okuma Alarm-B 2237 BRANCH (IF,GOTO) sequence name IF or GOTO statement includes no jump sequence number or a wrong jump sequence number. Object SYSTEM (None for schedule program) Code 1->Sequence…

Okuma Alarm-B 2238 BRANCH(IF,GOTO) condition

Okuma Alarm-B 2238 BRANCH(IF,GOTO) condition IF statement or condition judging expression is erroneous. Object SYSTEM (None with schedule program) Code 1->No “[” following IF 2->A comparison expression is not given…

Okuma Alarm-B 2239 Mistake in F command

Okuma Alarm-B 2239 Mistake in F command Numerical value of an F command in other than the G04 mode is either negative or zero. When the numerical value of an…

Okuma Alarm-B 2240 Mistake in F/E command

Okuma Alarm-B 2240 Mistake in F/E command Illegal F or E command When F or E command is converted into”microns/rev.” or “0.1 mm/min.” unit, the result of conversion does not…

Okuma Alarm-B 2234 EXPRESSION local variable

Okuma Alarm-B 2234 EXPRESSION local variable The local variable designated is not registered. Object SYSTEM Character-string:Local variable name designated Program Example:VTOFX[2]=BDIK ^^^^^Unregistered local variable Measures to Take Do not designate…

Okuma Alarm-B 2236 Program end code not found

Okuma Alarm-B 2236 Program end code not found No end code is specified at the end of a block. The symbol ‘(‘ is not concluded with ‘)’. The LAP end…