Okuma Alarms Errors
Okuma alarms and errors.
Okuma Alarm-B 2242 Mistake in J command
Okuma Alarm-B 2242 Mistake in J command Illegal J command Numerical value of J command is not: 0 < JJ value is negative 2->J value does not satisfy: 0 <...
Okuma Alarm-B 2243 Mistake in K command
Okuma Alarm-B 2243 Mistake in K command Illegal K command Numerical value of K command is not:-99999.999Hexadecimal number of K command in thread cutting fixed cycle. Hexadecimal number of K…
Okuma Alarm-B 2244 Mistake in L command
Okuma Alarm-B 2244 Mistake in L command Illegal L command Numerical value of L command in circular interpolation mode is not: 0 < L
Okuma Alarm-B 2245 Mistake in P command
Okuma Alarm-B 2245 Mistake in P command Illegal P command Numerical value of P command is not: -9999
Okuma Alarm-B 2246 Mistake in S command
Okuma Alarm-B 2246 Mistake in S command Illegal S command Numerical value of S command is not: 0
Okuma Alarm-B 2236 Program end code not found
Okuma Alarm-B 2236 Program end code not found No end code is specified at the end of a block. The symbol ‘(‘ is not concluded with ‘)’. The LAP end…
Okuma Alarm-B 2249 Mistake in X command
Okuma Alarm-B 2249 Mistake in X command Illegal X command Numerical value of X command is not: -99999.999
Okuma Alarm-B 2250 Mistake in X/Z command
Okuma Alarm-B 2250 Mistake in X/Z command The first block of the G31, G32 and G33 mode (thread cutting fixed cycle) has only either of X and Z commands, or…
Okuma Alarm-B 2251 Mistake in Z command
Okuma Alarm-B 2251 Mistake in Z command Illegal Z command Numerical value of Z command is not: -99999.999
Okuma Alarm-B 2252 Mistake in arc command
Okuma Alarm-B 2252 Mistake in arc command In direct arc radius command, the coordinates of the arc center cannot be calculated from the L command and X and Z commands….
Okuma Alarm-B 2253 Mistake in angle command
Okuma Alarm-B 2253 Mistake in angle command In the G00, G01, G02, G03, G34 or G35 sequence, an A command is designated both with X and Z commands. The target…
Okuma Alarm-B 2254 Mistake in thread cutting cycle command
Okuma Alarm-B 2254 Mistake in thread cutting cycle command In thread cutting fixed cycle, shift amount is so large as to reverse the cutting direction or taper amount is so…
Okuma Alarm-B 2257 Mistake in gauging cycle command
Okuma Alarm-B 2257 Mistake in gauging cycle command In G30 gauging cycle, the D command value is larger than the distance between the starting point and the point to be…
Okuma Alarm-B 2258 Mistake in C command
Okuma Alarm-B 2258 Mistake in C command Alarm of C command Numerical value of designated C command calling for spindle orientation is either C < 0-deg, or C >= 360-deg….
Okuma Alarm-B 2259 Mistake in SB command
Okuma Alarm-B 2259 Mistake in SB command Designated SB command is not: 0Hexadecimal number of commanded SB value Probable Faulty Locations Program error Program Example: N010 M13 SB=65000 Measures to…
Okuma Alarm-B 2260 Mistake in QA command
Okuma Alarm-B 2260 Mistake in QA command QA command(the number of C-axis revolutions for positioning) is designated for B-turret. QA command is designated in other than the G00 and G01…
Okuma Alarm-B 2261 Mistake in X/Y command
Okuma Alarm-B 2261 Mistake in X/Y command For coordinate system conversion, both X and Y are assigned with “zero”. Object SYSTEM Probable Faulty Locations Program error Program Example: G137 C20…
Okuma Alarm-B 2247 No S command
Okuma Alarm-B 2247 No S command The G96 or G97 sequence has no S command. G96: Constant speed cutting ON G97: Cancel of G96 Object SYSTEM Character-string:Coordinate systemG140, G141, G142…
Okuma Alarm-B 2268 Mistake in angle command
Okuma Alarm-B 2268 Mistake in angle command For the sequence calling automatic chamfering with an arbitrary angle or the one calling axis movement with only an A command, the command…
Okuma Alarm-B 2255 Mistake in arc radius command
Okuma Alarm-B 2255 Mistake in arc radius command 1)The sequence of G02 or G03 (circular interpolation) has both L and I, K commands. 2)The sequence of G02 or G03 block…
Okuma Alarm-B 2256 Mistake in D command
Okuma Alarm-B 2256 Mistake in D command Illegal D command In a gauging cycle, D value is not within a range of 0 and 99999.999. Or with cam turning specification…
Okuma Alarm-B 2275 Mistake in HP command
Okuma Alarm-B 2275 Mistake in HP command The data word HP command value designated with G20 home position command is outside of range, or the G20 block does not contain…
Okuma Alarm-B 2276 Mistake in CC command
Okuma Alarm-B 2276 Mistake in CC command The sub-spindle angle position designated using a CC command is greater than “359.999”, or it is a negative value. Object SYSTEM Code Hexadecimal…
Okuma Alarm-B 2262 Mistake in incremental command
Okuma Alarm-B 2262 Mistake in incremental command In the coordinate system conversion, the G code (G91) calling incremental mode is designated. In the composite fixed cycle execution, the incremental mode…
Okuma Alarm-B 2263 Command required for X-, Y-axes
Okuma Alarm-B 2263 Command required for X-, Y-axes For coordinate system conversion, only one of X and Y is designated. Object SYSTEM Probable Faulty Locations Program error Program Example: G137…
Okuma Alarm-B 2264 Mistake in Y command
Okuma Alarm-B 2264 Mistake in Y command For coordinate system conversion, the numerical value of “Y” is not within the following range: -99999.999Y command value is not in the range…
Okuma Alarm-B 2266 Mistake in R command
Okuma Alarm-B 2266 Mistake in R command In a block containing G181 through G184 or G189, either R=0 command is designated or an R command is designated with X and…
Okuma Alarm-B 2267 Mistake in drilling cycle command
Okuma Alarm-B 2267 Mistake in drilling cycle command In a block containing G181 through G184 or G189, following three commands are designated simultaneously: X, R and I, or Z, R…
Okuma Alarm-B 2270 Mistake in CD command
Okuma Alarm-B 2270 Mistake in CD command The CD (D for C-axis) command value has exceeded the relative distance from cycle start point to cycle target point. Code 1 Probable…
Okuma Alarm-B 2271 Mistake in CL command
Okuma Alarm-B 2271 Mistake in CL command The CL (L for C-axis) command value has exceeded the relative distance from cycle start point to cycle target point. Code 1 Probable…
Okuma Alarm-B 2273 Mistake in W command
Okuma Alarm-B 2273 Mistake in W command The sub-spindle axis motion command (W) is wrong. 1)A W-axis motion command is designated at the B-turret side. 2)A W-axis motion command is…
Okuma Alarm-B 2274 Mistake in CB command
Okuma Alarm-B 2274 Mistake in CB command The M-axis orientation angle command has a value smaller than 0 or larger than 360. Object SYSTEM Code Hexadecimal number of the designated…
Okuma Alarm-B 2277 Mistake in torque limit command
Okuma Alarm-B 2277 Mistake in torque limit command The torque limit command (G29) or torque skip (G22) command includes no torque command (PX, PZ) or has torque commands for two…
Okuma Alarm-B 2278 SUB PROGRAM repetition
Okuma Alarm-B 2278 SUB PROGRAM repetition A sub program repetition number other than 1 through 9999 is designated. Object SYSTEM Code Hexadecimal number of designated repetition number Probable Faulty Locations…
Okuma Alarm-B 2281 SUB PROGRAM data print
Okuma Alarm-B 2281 SUB PROGRAM data print The command for printing out gauging data is not designated correctly. Code 1->A command of a measure print does not have instructed rightly….