Selca G200 G201 G202 Cylindrical programming / Polar programming
Contents
G200 Cancels G201 and G202
G200 Cancels G201 and G202 (cylindrical/polar programming)
Programming
G200
G201 Cylindrical programming
G201 Cylindrical programming
Programming
G201 J... [K...]
Parameters
Parameter | Description |
---|---|
J | cylinder radius in millimeters |
K | specifies the unit of measure for the rotary axis coordinates: K1 degrees (default). K2 millimeters. |
Enabled: until a G200 is programmed.
G202 Polar programming
G202 Polar programming
Programming
G202
Enabled: until a G200 is programmed.