Sinumerik Alarms
Siemens Sinumerik Alarms Errors SINUMERIK 840D/840Di/810D
Sinumerik Alarm 120001 Area %1 cannot be selected. Please deactivate area %2
Sinumerik Alarm 120001 Area %1 cannot be selected. Please deactivate area %2 Parameters: %1 = Operating area name %2 = Operating area name Definitions: Within the scope of an area…
Sinumerik Alarm 120308 In the event of an emergency stop, the program %1 can only be changed in the machine/program correction area.
Sinumerik Alarm 120308 In the event of an emergency stop, the program %1 can only be changed in the machine/program correction area. Parameters: %1 = Program name with path Definitions:…
Sinumerik Alarm 300001 Axis %1 drive number %2 not possible
Sinumerik Alarm 300001 Axis %1 drive number %2 not possible Parameters: %1 = NC axis number %2 = Drive number Definitions: On powering up the drives, the NCK-specific machine data…
Sinumerik Alarm 120304 The selection is not possible. The file %1 has insufficient read rights.
Sinumerik Alarm 120304 The selection is not possible. The file %1 has insufficient read rights. Parameters: %1 = Program name with path Definitions: The file has insufficient read rights for…
Sinumerik Alarm 120003 Area %1 cannot be deactivated. Please try again
Sinumerik Alarm 120003 Area %1 cannot be deactivated. Please try again Parameters: %1 = Operating area name Definitions: Within the scope of an area switchover, an area is to be deselected….
Sinumerik Alarm 120306 The selection is not possible. The file %1 is selected and active in channel %2.
Sinumerik Alarm 120306 The selection is not possible. The file %1 is selected and active in channel %2. Parameters: %1 = Program name with path %2 = Channel number Definitions:…
Sinumerik Alarm 120307 The file %1 cannot be opened for the editor because it is selected in channel %2 for execution from external sources.
Sinumerik Alarm 120307 The file %1 cannot be opened for the editor because it is selected in channel %2 for execution from external sources. Parameters: %1 = Program name with…
Sinumerik Alarm 300004 Axis %1 drive %2 wrong drive type %3 (FDD/MSD)
Sinumerik Alarm 300004 Axis %1 drive %2 wrong drive type %3 (FDD/MSD) Parameters: %1 = NC axis number %2 = Drive number %3 = Drive type code Definitions: A feed…
Sinumerik Alarm 120120 The alarm list is full of alarm texts: Number of alarm texts too high Alarm texts:
Sinumerik Alarm 120120 The alarm list is full of alarm texts: Number of alarm texts too high Alarm texts: File %1 not found alarm texts: Input/Output error in file %1…
Sinumerik Alarm 300020 Drive %1 removed for diagnosis
Sinumerik Alarm 300020 Drive %1 removed for diagnosis Parameters: %1 = Drive number Definitions: The alarm indicates that the drive bus configuration has been changed temporarily. The alarm is output…
Sinumerik Alarm 300005 At least one module found on drive bus that has not been configured
Sinumerik Alarm 300005 At least one module found on drive bus that has not been configured Definitions: At bus initialization at least one module was detected which did not have…
Sinumerik Alarm 300006 Module with drive number %1 has not been found on drive bus
Sinumerik Alarm 300006 Module with drive number %1 has not been found on drive bus Parameters: %1 = Drive number Definitions: Not all of the drives stated in MD $MN_DRIVE_LOGIC_NR…
Sinumerik Alarm 300007 Axis %1 drive %2 not present or inactive
Sinumerik Alarm 300007 Axis %1 drive %2 not present or inactive Parameters: %1 = NC axis number %2 = Drive number Definitions: In the axis-specific machine data 30110 CTRLOUT_MODULE_NR (this…
Sinumerik Alarm 300010 Axis %1 drive %2 active without NC axis assignment
Sinumerik Alarm 300010 Axis %1 drive %2 active without NC axis assignment Parameters: %1 = NC axis number %2 = Drive number Definitions: A drive is active that is not…
Sinumerik Alarm 300410 Axis %1 drive %2 error when storing a file (%3, %4)
Sinumerik Alarm 300410 Axis %1 drive %2 error when storing a file (%3, %4) Parameters: %1 = NC axis number %2 = Drive number %3 = Error code 1 %4…
Sinumerik Alarm 300011 Axis %1 drive %2 hardware version of spindle not supported
Sinumerik Alarm 300011 Axis %1 drive %2 hardware version of spindle not supported Parameters: %1 = NC axis number %2 = Drive number Definitions: An old spindle power section (so-called…
Sinumerik Alarm 300411 Axis %1 drive %2 error when reading a file (%3, %4)
Sinumerik Alarm 300411 Axis %1 drive %2 error when reading a file (%3, %4) Parameters: %1 = NC axis number %2 = Drive number %3 = Error code 1 %4…
Sinumerik Alarm 300012 Axis %1 drive %2 hardware version of control module not supported
Sinumerik Alarm 300012 Axis %1 drive %2 hardware version of control module not supported Parameters: %1 = NC axis number %2 = Drive number Definitions: There is a drive module…
Sinumerik Alarm 300100 Drive power failure
Sinumerik Alarm 300100 Drive power failure Definitions: In one or several (all) drive modules, there is a power failure although power was previously available. (The timeout is checked for write/read…
Sinumerik Alarm 300101 Bus communications failure
Sinumerik Alarm 300101 Bus communications failure Definitions: This alarm indicates that there is still no power supply to the drives although the NC is already running. This message comes only…
Sinumerik Alarm 300200 Drive bus hardware fault
Sinumerik Alarm 300200 Drive bus hardware fault Definitions: The drive bus has a fault. The following causes are possible: • The bus terminator is missing. • The drive bus is…
Sinumerik Alarm 300300 Axis %1 drive %2 boot error, error code %3
Sinumerik Alarm 300300 Axis %1 drive %2 boot error, error code %3 Parameters: %1 = NC axis number %2 = Drive number %3 = Error code Definitions: Error occurred while…
Sinumerik Alarm 300400 Axis %1 drive %2 system error, error codes %3, %4
Sinumerik Alarm 300400 Axis %1 drive %2 system error, error codes %3, %4 Parameters: %1 = NC axis number %2 = Drive number %3 = Error code 1 %4 =…
Sinumerik Alarm 300402 System error in drive link. Error codes %1, %2
Sinumerik Alarm 300402 System error in drive link. Error codes %1, %2 Parameters: %1 = Error code 1 %2 = Error code 2 Definitions: An internal software error or serious…
Sinumerik Alarm 300008 Axis %1 drive %2 measuring circuit %3 is not available
Sinumerik Alarm 300008 Axis %1 drive %2 measuring circuit %3 is not available Parameters: %1 = NC axis number %2 = Drive number %3 = Measuring circuit number Definitions: In…
Sinumerik Alarm 300404 Axis %1 drive %2 drive MD contains different drive number
Sinumerik Alarm 300404 Axis %1 drive %2 drive MD contains different drive number Parameters: %1 = NC axis number %2 = Drive number Definitions: In the drive MD file loaded…
Sinumerik Alarm 300009 Axis %1 drive %2 measuring circuit %3 wrong measuring circuit type (type %4 used)
Sinumerik Alarm 300009 Axis %1 drive %2 measuring circuit %3 wrong measuring circuit type (type %4 used) Parameters: %1 = NC axis number %2 = Drive number %3 = Measuring…
Sinumerik Alarm 300405 Axis %1 drive %2 unknown drive alarm, code %3
Sinumerik Alarm 300405 Axis %1 drive %2 unknown drive alarm, code %3 Parameters: %1 = NC axis number %2 = Drive number %3 = Service number Definitions: The service number…
Sinumerik Alarm 300412 Error when storing a file (%1, %2)
Sinumerik Alarm 300412 Error when storing a file (%1, %2) Parameters: %1 = Error code 1 %2 = Error code 2 Definitions: An attempt to save a data block, i.e….
Sinumerik Alarm 300604 Axis %1 drive %2 motor encoder is not adjusted
Sinumerik Alarm 300604 Axis %1 drive %2 motor encoder is not adjusted Parameters: %1 = NC axis number %2 = Drive number Definitions: The stored serial number of the encoder…
Sinumerik Alarm 300413 Error when reading a file (%1, %2)
Sinumerik Alarm 300413 Error when reading a file (%1, %2) Parameters: %1 = Error code 1 %2 = Error code 2 Definitions: An attempt to read a data block, e.g….
Sinumerik Alarm 300605 Axis %1 drive %2 motor change not valid
Sinumerik Alarm 300605 Axis %1 drive %2 motor change not valid Parameters: %1 = NC axis number %2 = Drive number Definitions: An attempt was made to switch over to…
Sinumerik Alarm 300423 Measuring results could not be read (%1)
Sinumerik Alarm 300423 Measuring results could not be read (%1) Parameters: %1 = Error code Definitions: An attempt to read a measurement result has failed: • Error code = 4:…
Sinumerik Alarm 300500 Axis %1 drive %2 system error, error codes %3, %4
Sinumerik Alarm 300500 Axis %1 drive %2 system error, error codes %3, %4 Parameters: %1 = NC axis number %2 = Drive number %3 = Error code 1 %4 =…
Sinumerik Alarm 300201 Axis %1 drive %2 timeout during access, error location %3
Sinumerik Alarm 300201 Axis %1 drive %2 timeout during access, error location %3 Parameters: %1 = NC axis number %2 = Drive number %3 = Error location Definitions: The read…