Sinumerik Alarms
Siemens Sinumerik Alarms Errors SINUMERIK 840D/840Di/810D
Sinumerik Alarm 105041 Block number is too large!
Sinumerik Alarm 105041 Block number is too large! Definitions: The set increment and the size of the program cause the block number to be greater than 999999. Reactions: – –…
Sinumerik Alarm 300731 Axis %1 drive %2 rated power less than or equal to zero
Sinumerik Alarm 300731 Axis %1 drive %2 rated power less than or equal to zero Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in MD…
Sinumerik Alarm 105042 Impermissible block number!
Sinumerik Alarm 105042 Impermissible block number! Definitions: The first block number is less than 0 or greater than 999999. Reactions: – – Remedy: – Program Continuation: Internal
Sinumerik Alarm 300732 Axis %1 drive %2 rated speed less than or equal to zero
Sinumerik Alarm 300732 Axis %1 drive %2 rated speed less than or equal to zero Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in MD…
Sinumerik Alarm 300735 Axis %1 drive %2 field weakening speed invalid
Sinumerik Alarm 300735 Axis %1 drive %2 field weakening speed invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in MD 1142: $MD_FIELD_WEAKENING_SPEED (threshold speed…
Sinumerik Alarm 300745 Axis %1 drive %2 limit values for safe end positions exchanged
Sinumerik Alarm 300745 Axis %1 drive %2 limit values for safe end positions exchanged Parameters: %1 = NC axis number %2 = Drive number Definitions: For the safe end position…
Sinumerik Alarm 300734 Axis %1 drive %2 zero load current less than or equal to zero
Sinumerik Alarm 300734 Axis %1 drive %2 zero load current less than or equal to zero Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in…
Sinumerik Alarm 300736 Axis %1 drive %2 Lh characteristic invalid
Sinumerik Alarm 300736 Axis %1 drive %2 Lh characteristic invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in MD 1143: $MD_LH_CURVE_UPPER_SPEED (LH curve upper…
Sinumerik Alarm 300737 Axis %1 drive %2 configuration of two EnDat encoders not possible
Sinumerik Alarm 300737 Axis %1 drive %2 configuration of two EnDat encoders not possible Parameters: %1 = NC axis number %2 = Drive number Definitions: The MCU hardware does not…
Sinumerik Alarm 300738 Axis %1 drive %2 module number for measuring system not possible
Sinumerik Alarm 300738 Axis %1 drive %2 module number for measuring system not possible Parameters: %1 = NC axis number %2 = Drive number Definitions: The NC has assigned the…
Sinumerik Alarm 300739 Axis %1 drive %2 measuring system already used as motor measuring system
Sinumerik Alarm 300739 Axis %1 drive %2 measuring system already used as motor measuring system Parameters: %1 = NC axis number %2 = Drive number Definitions: The NC has assigned…
Sinumerik Alarm 300740 Axis %1 drive %2 measuring system used several times
Sinumerik Alarm 300740 Axis %1 drive %2 measuring system used several times Parameters: %1 = NC axis number %2 = Drive number Definitions: The NC has assigned the direct measuring…
Sinumerik Alarm 300741 Axis %1 drive %2 asynchronous mode: feedforward control gain out of range
Sinumerik Alarm 300741 Axis %1 drive %2 asynchronous mode: feedforward control gain out of range Parameters: %1 = NC axis number %2 = Drive number Definitions: If motor inertia and…
Sinumerik Alarm 300742 Axis %1 drive %2 voltage/frequency mode: converter frequency invalid
Sinumerik Alarm 300742 Axis %1 drive %2 voltage/frequency mode: converter frequency invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: Only converter frequencies (MD 1100: $MD_PWM_FREQUENCY (pulse…
Sinumerik Alarm 300743 Axis %1 drive %2 function not supported on this 611D controller module
Sinumerik Alarm 300743 Axis %1 drive %2 function not supported on this 611D controller module Parameters: %1 = NC axis number %2 = Drive number Definitions: The 611D Performance control…
Sinumerik Alarm 300744 Axis %1 drive %2 safety monitoring checksum invalid, confirmation and acceptance test required!
Sinumerik Alarm 300744 Axis %1 drive %2 safety monitoring checksum invalid, confirmation and acceptance test required! Parameters: %1 = NC axis number %2 = Drive number Definitions: The actual checksum…
Sinumerik Alarm 300733 Axis %1 drive %2 zero load voltage invalid
Sinumerik Alarm 300733 Axis %1 drive %2 zero load voltage invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: Error in the no-load voltage (MD 1135): •…
Sinumerik Alarm 300752 Axis %1 drive %2 blocking frequency of setpoint current filter too high
Sinumerik Alarm 300752 Axis %1 drive %2 blocking frequency of setpoint current filter too high Parameters: %1 = NC axis number %2 = Drive number Definitions: The blocking frequency of…
Sinumerik Alarm 300753 Axis %1 drive %2 rotor position identification current less than minimal value
Sinumerik Alarm 300753 Axis %1 drive %2 rotor position identification current less than minimal value Parameters: %1 = NC axis number %2 = Drive number Definitions: The current set in…
Sinumerik Alarm 300755 Axis %1 drive %2 voltage/frequency mode: motor is turning
Sinumerik Alarm 300755 Axis %1 drive %2 voltage/frequency mode: motor is turning Parameters: %1 = NC axis number %2 = Drive number Definitions: The motor did not come to a…
Sinumerik Alarm 300756 Axis %1 drive %2 speed hysteresis of setpoint current smoothing invalid
Sinumerik Alarm 300756 Axis %1 drive %2 speed hysteresis of setpoint current smoothing invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in MD 1246:…
Sinumerik Alarm 300760 Axis %1 drive %2 generator mode: emergency retraction speed > max. motor speed
Sinumerik Alarm 300760 Axis %1 drive %2 generator mode: emergency retraction speed > max. motor speed Parameters: %1 = NC axis number %2 = Drive number Definitions: The value entered…
Sinumerik Alarm 300761 Axis %1 drive %2 generator mode: minimum axis speed > max. motor speed
Sinumerik Alarm 300761 Axis %1 drive %2 generator mode: minimum axis speed > max. motor speed Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in…
Sinumerik Alarm 300746 Axis %1 drive %2 SBH/SG not enabled
Sinumerik Alarm 300746 Axis %1 drive %2 SBH/SG not enabled Parameters: %1 = NC axis number %2 = Drive number Definitions: In the machine data 1301: $MD_SAFE_FUNCTION_ENABLE (safe functions enable)…
Sinumerik Alarm 300762 Axis %1 drive %2 emergency retraction mode/generator mode already active
Sinumerik Alarm 300762 Axis %1 drive %2 emergency retraction mode/generator mode already active Parameters: %1 = NC axis number %2 = Drive number Definitions: Emergency retraction or generator mode already…
Sinumerik Alarm 300784 Axis %1 drive %2 zero load voltage invalid
Sinumerik Alarm 300784 Axis %1 drive %2 zero load voltage invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: Error in the no-load voltage (MD 1135): •…
Sinumerik Alarm 300785 Axis %1 drive %2 zero load current less than or equal to zero
Sinumerik Alarm 300785 Axis %1 drive %2 zero load current less than or equal to zero Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in…
Sinumerik Alarm 300754 Axis %1 drive %2 signal number of var. signaling function invalid
Sinumerik Alarm 300754 Axis %1 drive %2 signal number of var. signaling function invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The signal number for the…
Sinumerik Alarm 300757 Axis %1 drive %2 adaption factor of torque limit invalid
Sinumerik Alarm 300757 Axis %1 drive %2 adaption factor of torque limit invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The torque adaptation factor MD 1191:…
Sinumerik Alarm 300758 Axis %1 drive %2 generator mode: response voltage > switch-off threshold
Sinumerik Alarm 300758 Axis %1 drive %2 generator mode: response voltage > switch-off threshold Parameters: %1 = NC axis number %2 = Drive number Definitions: The sum of the values…
Sinumerik Alarm 300759 Axis %1 drive %2 generator mode: response voltage > monitoring threshold
Sinumerik Alarm 300759 Axis %1 drive %2 generator mode: response voltage > monitoring threshold Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in MD 1631:…
Sinumerik Alarm 300747 Axis %1 drive %2 monitoring cycle time MD 1300 invalid
Sinumerik Alarm 300747 Axis %1 drive %2 monitoring cycle time MD 1300 invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: Check and, if necessary, correct MD…
Sinumerik Alarm 300748 Axis %1 drive %2 monitoring cycle times of both axes differ
Sinumerik Alarm 300748 Axis %1 drive %2 monitoring cycle times of both axes differ Parameters: %1 = NC axis number %2 = Drive number Definitions: The monitoring cycles set in…
Sinumerik Alarm 300749 Axis %1 drive %2 conversion factor between motor and load too large
Sinumerik Alarm 300749 Axis %1 drive %2 conversion factor between motor and load too large Parameters: %1 = NC axis number %2 = Drive number Definitions: The conversion factor from…
Sinumerik Alarm 300750 Axis %1 drive %2 parameterization error in speed control adaption
Sinumerik Alarm 300750 Axis %1 drive %2 parameterization error in speed control adaption Parameters: %1 = NC axis number %2 = Drive number Definitions: The upper adaptation speed MD 1412:…