Sinumerik Alarms
Siemens Sinumerik Alarms Errors SINUMERIK 840D/840Di/810D
Sinumerik Alarm 27254 PROFIsafe: F module %1, error on channel %2; %3 ALSI
Sinumerik Alarm 27254 PROFIsafe: F module %1, error on channel %2; %3 <ALSI> Parameters: %1 = PROFIsafe address %2 = Channel number %3 = System variable array index extension Definitions: The…
Sinumerik Alarm 27253 PROFIsafe: communication fault F master component %1, error %2
Sinumerik Alarm 27253 PROFIsafe: communication fault F master component %1, error %2 Parameters: %1 = Error component (NCK/PLC) %2 = Error code Definitions: The F master signals that the communication…
Sinumerik Alarm 27252 PROFIsafe: Slave %1, sign-of-life error
Sinumerik Alarm 27252 PROFIsafe: Slave %1, sign-of-life error Parameters: %1 = DP slave address Definitions: The specified DP slave no longer communicates with the master. Stop D/E is triggered. Reactions:…
Sinumerik Alarm 27251 PROFIsafe: F module %1, %2 reports error %3
Sinumerik Alarm 27251 PROFIsafe: F module %1, %2 reports error %3 Parameters: %1 = PROFIsafe address %2 = Reporting component (master/slave) %3 = Error code Definitions: An error occurred in…
Sinumerik Alarm 27250 PROFIsafe: configuration in DP M changed; error code %1 – %2
Sinumerik Alarm 27250 PROFIsafe: configuration in DP M changed; error code %1 – %2 Parameters: %1 = NCK project number %2 = Current PLC project number Definitions: The DP master…
Sinumerik Alarm 27242 PROFIsafe: F module %1, %2 faulty
Sinumerik Alarm 27242 PROFIsafe: F module %1, %2 faulty Parameters: %1 = PROFIsafe address %2 = Incorrect F parameter Definitions: An error was detected during the evaluation of the F…
Sinumerik Alarm 27241 PROFIsafe: DP M version different, NCK: %1, PLC: %2
Sinumerik Alarm 27241 PROFIsafe: DP M version different, NCK: %1, PLC: %2 Parameters: %1 = DP interface version of the NCK %2 = DP interface version of the PLC Definitions:…
Sinumerik Alarm 27240 PROFIsafe: DP M not running up, DP info: %1
Sinumerik Alarm 27240 PROFIsafe: DP M not running up, DP info: %1 Parameters: %1 = Current information from the DP interface NCK-PLC Definitions: There is no DP configuration available to…
Sinumerik Alarm 27225 PROFI safe: slave %1, configuration error %2
Sinumerik Alarm 27225 PROFIsafe: slave %1, configuration error %2 Parameters: %1 = PROFIBUS slave address %2 = Configuration error Definitions: An error occurred during the evaluation of the S7 PROFIBUS…
Sinumerik Alarm 27224 PROFI safe: F module MD %1[%2] – MD %3[%4]: double assignment of PROFI safe address
Sinumerik Alarm 27224 PROFI safe: F module MD %1[%2] – MD %3[%4]: double assignment of PROFI safe address Parameters: %1 = MD name 1 %2 = MD field index 1…
Sinumerik Alarm 27223 PROFI safe: NCK F module MD %1[%2] is not a %3 module
Sinumerik Alarm 27223 PROFIsafe: NCK F module MD %1[%2] is not a %3 module Parameters: %1 = MD name %2 = MD field index %3 = Module type Definitions: The…
Sinumerik Alarm 27222 PROFI safe: S7 F module PROFI safe address %1 unknown
Sinumerik Alarm 27222 PROFIsafe: S7 F module PROFIsafe address %1 unknown Parameters: %1 = PROFIsafe address Definitions: The F module with the specified PROFIsafe address has not been parameterized as…
Sinumerik Alarm 27221 PROFIsafe: NCK F module MD %1[%2] unknown
Sinumerik Alarm 27221 PROFIsafe: NCK F module MD %1[%2] unknown Parameters: %1 = MD name %2 = MD field index Definitions: The F module parameterized in the specified machine data…
Sinumerik Alarm 27220 PROFIsafe: Number of NCK F modules (%1) <> number of DP modules (%2)
Sinumerik Alarm 27220 PROFIsafe: Number of NCK F modules (%1) number of DP modules (%2) Parameters: %1 = Number of parameterized NCK F modules %2 = Number of parameterized S7…
Sinumerik Alarm 27204 PROFIsafe: double assignment MD %1[%2] – MD %3[%4]
Sinumerik Alarm 27204 PROFIsafe: double assignment MD %1[%2] – MD %3[%4] Parameters: %1 = MD name 1 %2 = MD field index of MD name 1 %3 = MD name…
Sinumerik Alarm 27203 PROFIsafe: MD %1[%2]: SPL assignment error
Sinumerik Alarm 27203 PROFIsafe: MD %1[%2]: SPL assignment error Parameters: %1 = MD name %2 = MD field index Definitions: The parameterization of the specified machine data for the link…
Sinumerik Alarm 27202 PROFIsafe: MD %1[%2]: address %3 error
Sinumerik Alarm 27202 PROFIsafe: MD %1[%2]: address %3 error Parameters: %1 = MD name %2 = MD field index %3 = Parameterized PROFIsafe address Definitions: An incorrect PROFIsafe address was…
Sinumerik Alarm 27201 PROFIsafe: MD %1[%2]: bus segment %3 error
Sinumerik Alarm 27201 PROFIsafe: MD %1[%2]: bus segment %3 error Parameters: %1 = MD name %2 = MD field index %3 = Parameterized bus segment Definitions: An incorrect bus segment…
Sinumerik Alarm 27200 PROFIsafe: cycle time %1 [ms] too long
Sinumerik Alarm 27200 PROFIsafe: cycle time %1 [ms] too long Parameters: %1 = Parameterized cycle time Definitions: The PROFIsafe communication cycle time resulting from MD $MN_PROFISAFE_IPO_TIME_RATIO and MD $MN_IPO_CYCLE_TIME exceeds…
Sinumerik Alarm 27124 Stop A triggered at least in 1 axis
Sinumerik Alarm 27124 Stop A triggered at least in 1 axis Definitions: This is only an informational alarm indicating that Stop A has been triggered in at least one axis…
Sinumerik Alarm 27107 Axis %1 difference in function cam modulo monitoring, NCK: %2 drive: %3
Sinumerik Alarm 27107 Axis %1 difference in function cam modulo monitoring, NCK: %2 drive: %3 Parameters: %1 = Axis number %2 = Monitoring status safe cam modulo range %3 =…
Sinumerik Alarm 27106 Axis %1 difference in function safe velocity nx, NCK: %2 drive: %3
Sinumerik Alarm 27106 Axis %1 difference in function safe velocity nx, NCK: %2 drive: %3 Parameters: %1 = Axis number %2 = Monitoring status safe velocity nx %3 = Monitoring…
Sinumerik Alarm 27105 Axis %1 difference in function safe cam minus %2, NCK: %3 drive: %4
Sinumerik Alarm 27105 Axis %1 difference in function safe cam minus %2, NCK: %3 drive: %4 Parameters: %1 = Axis number %2 = Cam number %3 = Monitoring status safe…
Sinumerik Alarm 27104 Axis %1 difference in function safe cam plus %2, NCK: %3 drive: %4
Sinumerik Alarm 27104 Axis %1 difference in function safe cam plus %2, NCK: %3 drive: %4 Parameters: %1 = Axis number %2 = Cam number %3 = Monitoring status safe…
Sinumerik Alarm 27103 Axis %1 difference in function safe limit position %2, NCK: %3 drive: %4
Sinumerik Alarm 27103 Axis %1 difference in function safe limit position %2, NCK: %3 drive: %4 Parameters: %1 = Axis number %2 = Number of safe limit position %3 =…
Sinumerik Alarm 27102 Axis %1 difference in function safe velocity %2, NCK: %3 drive: %4
Sinumerik Alarm 27102 Axis %1 difference in function safe velocity %2, NCK: %3 drive: %4 Parameters: %1 = Axis number %2 = SG level for which the difference was determined…
Sinumerik Alarm 27101 Axis %1 difference in function safe operational stop, NCK: %2 drive: %3
Sinumerik Alarm 27101 Axis %1 difference in function safe operational stop, NCK: %2 drive: %3 Parameters: %1 = Axis number %2 = Monitoring status safe operating stop %3 = Monitoring…
Sinumerik Alarm 27100 At least one axis is not safely referenced
Sinumerik Alarm 27100 At least one axis is not safely referenced Definitions: There are two reasons for this alarm: • the machine position of at least one of the axes…
Sinumerik Alarm 27096 SPL start not allowed
Sinumerik Alarm 27096 SPL start not allowed Definitions: To start the SPL in protected state (MD $MN_PREVENT_SYNACT_LOCK[0,1] not equal 0) Safety Integrated functionality must first be activated for at least…
Sinumerik Alarm 27095 %1 SPL protection not activated
Sinumerik Alarm 27095 %1 SPL protection not activated Parameters: %1 = Name of the component on which the protection is not activated (NCK or PLC) Definitions: The protection features are…
Sinumerik Alarm 27094 Write access to system variable %1 only allowed from NCK-SPL
Sinumerik Alarm 27094 Write access to system variable %1 only allowed from NCK-SPL Parameters: %1 = Name of safety system variable concerned Definitions: Write access to a safety system variable…
Sinumerik Alarm 27093 Checksum error NCK-SPL, %1, %2, %3
Sinumerik Alarm 27093 Checksum error NCK-SPL, %1, %2, %3 Parameters: %1 = Extension indicating the type of error %2 = Extension indicating the reference variable %3 = Extension indicating the…
Sinumerik Alarm 27092 Communication broken off during NCK PLC data cross check, error detected by %1
Sinumerik Alarm 27092 Communication broken off during NCK PLC data cross check, error detected by %1 Parameters: %1 = Extension indicating the monitoring channel that detected the error Definitions: The…
Sinumerik Alarm 27091 Error in data cross check NCK PLC, stop of %1
Sinumerik Alarm 27091 Error in data cross check NCK PLC, stop of %1 Parameters: %1 = Extension indicating the monitoring channel that triggered the stop Definitions: The monitoring channel specified…
Sinumerik Alarm 27090 Error in data cross check NCK-PLC, %1[%2], NCK: %3; %4 ALSI
Sinumerik Alarm 27090 Error in data cross check NCK-PLC, %1[%2], NCK: %3; %4 <ALSI> Parameters: %1 = Name of system variable in which the error was detected %2 = System variable…