Sinumerik Alarms

Siemens Sinumerik Alarms Errors SINUMERIK 840D/840Di/810D

Sinumerik Alarm 22051 Channel %1 block %3 spindle %2 reference mark not found

Sinumerik Alarm 22051 Channel %1 block %3 spindle %2 reference mark not found Parameters: %1 = Channel number %2 = Axis name, spindle number %3 = Block number, label Definitions:…

Sinumerik Alarm 22050 Channel %1 block %3 spindle %2 no transition from speed control mode to position control mode

Sinumerik Alarm 22050 Channel %1 block %3 spindle %2 no transition from speed control mode to position control mode Parameters: %1 = Channel number %2 = Axis name, spindle number…

Sinumerik Alarm 22045 Block %2 spindle/axis %3 not available in channel %1 because active in channel %4

Sinumerik Alarm 22045 Block %2 spindle/axis %3 not available in channel %1 because active in channel %4 Parameters: %1 = Channel number %2 = Block number, label %3 = Axis…

Sinumerik Alarm 22040 Channel %1 block %3 spindle %2 is not referenced with zero marker

Sinumerik Alarm 22040 Channel %1 block %3 spindle %2 is not referenced with zero marker Parameters: %1 = Channel number %2 = Axis name, spindle number %3 = Block number,…

Sinumerik Alarm 22020 Channel %1 block %3 spindle %2 gear step change position not reached

Sinumerik Alarm 22020 Channel %1 block %3 spindle %2 gear step change position not reached Parameters: %1 = Channel number %2 = Spindle number %3 = Block number, label Definitions:…

Sinumerik Alarm 22014 Channel %1 block %2. The dynamics of leading spindle %3 and dependent spindle %4 is too variably

Sinumerik Alarm 22014 Channel %1 block %2. The dynamics of leading spindle %3 and dependent spindle %4 is too variably Parameters: %1 = Channel number %2 = Block number, label…

Sinumerik Alarm 22013 Channel %1 block %2 dependent spindle %3 is in simulation.

Sinumerik Alarm 22013 Channel %1 block %2 dependent spindle %3 is in simulation. Parameters: %1 = Channel number %2 = Block number, label %3 = Following spindle number Definitions: When…

Sinumerik Alarm 22012 Channel %1 block %2 leading spindle %3 is in simulation.

Sinumerik Alarm 22012 Channel %1 block %2 leading spindle %3 is in simulation. Parameters: %1 = Channel number %2 = Block number, label %3 = Leading spindle number Definitions: When…

Sinumerik Alarm 22011 Channel %1 block %3 spindle %2 change to programmed gear stage not possible

Sinumerik Alarm 22011 Channel %1 block %3 spindle %2 change to programmed gear stage not possible Parameters: %1 = Channel number %2 = Spindle number %3 = Block number, label…

Sinumerik Alarm 22010 Channel %1 block %3 spindle %2 actual gear stage differs from requested gear stage

Sinumerik Alarm 22010 Channel %1 block %3 spindle %2 actual gear stage differs from requested gear stage Parameters: %1 = Channel number %2 = Spindle number %3 = Block number,…

Sinumerik Alarm 22000 Channel %1 block %3 spindle %2 change of gear stage not possible

Sinumerik Alarm 22000 Channel %1 block %3 spindle %2 change of gear stage not possible Parameters: %1 = Channel number %2 = Spindle number %3 = Block number, label Definitions:…

Sinumerik Alarm 21800 Channel %1 workpiece setpoint %2 reached

Sinumerik Alarm 21800 Channel %1 workpiece setpoint %2 reached Parameters: %1 = Channel number %2 = Workpiece setpoint Definitions: This alarm is activated via MD 27880 PART_COUNTER, bit 1: The…

Sinumerik Alarm 21760 Channel %1 block %2 too many auxiliary functions programmed

Sinumerik Alarm 21760 Channel %1 block %2 too many auxiliary functions programmed Parameters: %1 = Channel number %2 = Block number, label Definitions: The number of programmed auxiliary functions has…

Sinumerik Alarm 21750 Error during output of cam signals via timer

Sinumerik Alarm 21750 Error during output of cam signals via timer Definitions: The signal output activated by the MD 10480 SW_CAM_TIMER_FASTOUT_MASK via the hardware timer (independent of the clock grid)…

Sinumerik Alarm 21740 Output value at analog output no. %1 has been limited

Sinumerik Alarm 21740 Output value at analog output no. %1 has been limited Parameters: %1 = No. of output Definitions: The value range of the analog output n is limited…

Sinumerik Alarm 21703 Channel %1 block %3 axis %2 touch probe not deflected, illegal edge polarity

Sinumerik Alarm 21703 Channel %1 block %3 axis %2 touch probe not deflected, illegal edge polarity Parameters: %1 = Channel number %2 = Axis name, spindle number %3 = Block…

Sinumerik Alarm 21702 Channel %1 block %3 axis %2 measurement aborted

Sinumerik Alarm 21702 Channel %1 block %3 axis %2 measurement aborted Parameters: %1 = Channel number %2 = Axis name, spindle number %3 = Block number Definitions: The measurement block…

Sinumerik Alarm 21701 Channel %1 block %3 axis %2 measurement not possible

Sinumerik Alarm 21701 Channel %1 block %3 axis %2 measurement not possible Parameters: %1 = Channel number %2 = Axis name, spindle number %3 = Block number Definitions: Measurement level…

Sinumerik Alarm 21700 Channel %1 block %3 axis %2 touch probe already deflected, edge polarity not possible

Sinumerik Alarm 21700 Channel %1 block %3 axis %2 touch probe already deflected, edge polarity not possible Parameters: %1 = Channel number %2 = Axis name, spindle number %3 =…

Sinumerik Alarm 21670 Channel %1 block %2 illegal change of tool direction with $AA_TOFF active

Sinumerik Alarm 21670 Channel %1 block %2 illegal change of tool direction with $AA_TOFF active Parameters: %1 = Channel number %2 = Block number, label Definitions: If an offset has…

Sinumerik Alarm 21665 Channel %1 $AA_TOFF cleared

Sinumerik Alarm 21665 Channel %1 $AA_TOFF cleared Parameters: %1 = Channel number Definitions: If the tool position is changed with RESET and $AA_TOFF is active during RESET, the position offset…

Sinumerik Alarm 21660 Channel %1 block %2 axis %3 conflict between SYNACT: $AA_OFF and CORROF

Sinumerik Alarm 21660 Channel %1 block %2 axis %3 conflict between SYNACT: $AA_OFF and CORROF Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name Definitions:…

Sinumerik Alarm 21650 Channel %1 axis %2 overlaid motion not allowed

Sinumerik Alarm 21650 Channel %1 axis %2 overlaid motion not allowed Parameters: %1 = Channel number %2 = Axis name, spindle number Definitions: An overlaid motion was requested for the…

Sinumerik Alarm 21619 Channel %1 block %2 transformation active: motion not possible

Sinumerik Alarm 21619 Channel %1 block %2 transformation active: motion not possible Parameters: %1 = Channel number %2 = Block number, label Definitions: The machine kinematics does not allow the…

Sinumerik Alarm 21618 Channel %1 as from block %2 transformation active: overlaid motion too great

Sinumerik Alarm 21618 Channel %1 as from block %2 transformation active: overlaid motion too great Parameters: %1 = Channel number %2 = Block number, label Definitions: The share of overlaid…

Sinumerik Alarm 21617 Channel %1 block %2 transformation does not allow to traverse the pole

Sinumerik Alarm 21617 Channel %1 block %2 transformation does not allow to traverse the pole Parameters: %1 = Channel number %2 = Block number, label Definitions: The preset curve passes…

Sinumerik Alarm 21616 Channel %1 block %2 overlaid motion active at transformation switchover

Sinumerik Alarm21616 Channel %1 block %2 overlaid motion active at transformation switchover Parameters: %1 = Channel number %2 = Block number, label Definitions: The overlaid motion in the BCS changes…

Sinumerik Alarm 21615 Channel %1 axis %2 taken from traverse mode to follow-up mode

Sinumerik Alarm 21615 Channel %1 axis %2 taken from traverse mode to follow-up mode Parameters: %1 = Channel number %2 = Axis name, spindle number Definitions: This axis has been…

Sinumerik Alarm 21614 Channel %1 axis %2 hardware limit switch %3

Sinumerik Alarm 21614 Channel %1 axis %2 hardware limit switch %3 Parameters: %1 = Channel number %2 = Axis name, spindle number %3 = String (+, – or +/-) Definitions:…

Sinumerik Alarm 21613 Axis %1 measuring system changing

Sinumerik Alarm 21613 Axis %1 measuring system changing Parameters: %1 = Axis name, spindle number Definitions: The measuring system for this axis is changing. Reactions: – Alarm display. Remedy: –…

Sinumerik Alarm 21612 Channel %1 axis %2 VDI signal ‘Servo enable’ reset during motion

Sinumerik Alarm 21612 Channel %1 axis %2 VDI signal ‘Servo enable’ reset during motion Parameters: %1 = Channel number %2 = Axis name, spindle number Definitions: The interface signal “Servo…

Sinumerik Alarm 21611 Channel %1 NC-controlled Extended Stop/Retract triggered

Sinumerik Alarm 21611 Channel %1 NC-controlled Extended Stop/Retract triggered Parameters: %1 = Channel number Definitions: “NC-controlled Extended Stop/Retract” triggered. Reactions: – Channel not ready. – NC Stop on alarm. –…

Sinumerik Alarm 21610 Channel %1 axis %2 encoder %3 frequency limit exceeded

Sinumerik Alarm 21610 Channel %1 axis %2 encoder %3 frequency limit exceeded Parameters: %1 = Channel number %2 = Axis name, spindle number %3 = String (encoder number) Definitions: The…

Sinumerik Alarm 21600 Monitoring for ESR active

Sinumerik Alarm 21600 Monitoring for ESR active Definitions: – Reactions: – Alarm display. – NC not ready. – All alarm reactions are delayed by one IPO cycle with this alarm….

Sinumerik Alarm 20211 Channel %1 block %3 spindle %2 support point beyond range limits

Sinumerik Alarm 20211 Channel %1 block %3 spindle %2 support point beyond range limits Parameters: %1 = Channel number %2 = Spindle number %3 = Block number, label Definitions: The…