Sinumerik Alarms
Siemens Sinumerik Alarms Errors SINUMERIK 840D/840Di/810D
Sinumerik Alarm 22051 Channel %1 block %3 spindle %2 reference mark not found
Sinumerik Alarm 22051 Channel %1 block %3 spindle %2 reference mark not found Parameters: %1 = Channel number %2 = Axis name, spindle number %3 = Block number, label Definitions:…
Sinumerik Alarm 22050 Channel %1 block %3 spindle %2 no transition from speed control mode to position control mode
Sinumerik Alarm 22050 Channel %1 block %3 spindle %2 no transition from speed control mode to position control mode Parameters: %1 = Channel number %2 = Axis name, spindle number…
Sinumerik Alarm 22045 Block %2 spindle/axis %3 not available in channel %1 because active in channel %4
Sinumerik Alarm 22045 Block %2 spindle/axis %3 not available in channel %1 because active in channel %4 Parameters: %1 = Channel number %2 = Block number, label %3 = Axis…
Sinumerik Alarm 22040 Channel %1 block %3 spindle %2 is not referenced with zero marker
Sinumerik Alarm 22040 Channel %1 block %3 spindle %2 is not referenced with zero marker Parameters: %1 = Channel number %2 = Axis name, spindle number %3 = Block number,…
Sinumerik Alarm 22020 Channel %1 block %3 spindle %2 gear step change position not reached
Sinumerik Alarm 22020 Channel %1 block %3 spindle %2 gear step change position not reached Parameters: %1 = Channel number %2 = Spindle number %3 = Block number, label Definitions:…
Sinumerik Alarm 22014 Channel %1 block %2. The dynamics of leading spindle %3 and dependent spindle %4 is too variably
Sinumerik Alarm 22014 Channel %1 block %2. The dynamics of leading spindle %3 and dependent spindle %4 is too variably Parameters: %1 = Channel number %2 = Block number, label…
Sinumerik Alarm 22013 Channel %1 block %2 dependent spindle %3 is in simulation.
Sinumerik Alarm 22013 Channel %1 block %2 dependent spindle %3 is in simulation. Parameters: %1 = Channel number %2 = Block number, label %3 = Following spindle number Definitions: When…
Sinumerik Alarm 22012 Channel %1 block %2 leading spindle %3 is in simulation.
Sinumerik Alarm 22012 Channel %1 block %2 leading spindle %3 is in simulation. Parameters: %1 = Channel number %2 = Block number, label %3 = Leading spindle number Definitions: When…
Sinumerik Alarm 22011 Channel %1 block %3 spindle %2 change to programmed gear stage not possible
Sinumerik Alarm 22011 Channel %1 block %3 spindle %2 change to programmed gear stage not possible Parameters: %1 = Channel number %2 = Spindle number %3 = Block number, label…
Sinumerik Alarm 22010 Channel %1 block %3 spindle %2 actual gear stage differs from requested gear stage
Sinumerik Alarm 22010 Channel %1 block %3 spindle %2 actual gear stage differs from requested gear stage Parameters: %1 = Channel number %2 = Spindle number %3 = Block number,…
Sinumerik Alarm 22000 Channel %1 block %3 spindle %2 change of gear stage not possible
Sinumerik Alarm 22000 Channel %1 block %3 spindle %2 change of gear stage not possible Parameters: %1 = Channel number %2 = Spindle number %3 = Block number, label Definitions:…
Sinumerik Alarm 21800 Channel %1 workpiece setpoint %2 reached
Sinumerik Alarm 21800 Channel %1 workpiece setpoint %2 reached Parameters: %1 = Channel number %2 = Workpiece setpoint Definitions: This alarm is activated via MD 27880 PART_COUNTER, bit 1: The…
Sinumerik Alarm 21760 Channel %1 block %2 too many auxiliary functions programmed
Sinumerik Alarm 21760 Channel %1 block %2 too many auxiliary functions programmed Parameters: %1 = Channel number %2 = Block number, label Definitions: The number of programmed auxiliary functions has…
Sinumerik Alarm 21750 Error during output of cam signals via timer
Sinumerik Alarm 21750 Error during output of cam signals via timer Definitions: The signal output activated by the MD 10480 SW_CAM_TIMER_FASTOUT_MASK via the hardware timer (independent of the clock grid)…
Sinumerik Alarm 21740 Output value at analog output no. %1 has been limited
Sinumerik Alarm 21740 Output value at analog output no. %1 has been limited Parameters: %1 = No. of output Definitions: The value range of the analog output n is limited…
Sinumerik Alarm 21703 Channel %1 block %3 axis %2 touch probe not deflected, illegal edge polarity
Sinumerik Alarm 21703 Channel %1 block %3 axis %2 touch probe not deflected, illegal edge polarity Parameters: %1 = Channel number %2 = Axis name, spindle number %3 = Block…
Sinumerik Alarm 21702 Channel %1 block %3 axis %2 measurement aborted
Sinumerik Alarm 21702 Channel %1 block %3 axis %2 measurement aborted Parameters: %1 = Channel number %2 = Axis name, spindle number %3 = Block number Definitions: The measurement block…
Sinumerik Alarm 21701 Channel %1 block %3 axis %2 measurement not possible
Sinumerik Alarm 21701 Channel %1 block %3 axis %2 measurement not possible Parameters: %1 = Channel number %2 = Axis name, spindle number %3 = Block number Definitions: Measurement level…
Sinumerik Alarm 21700 Channel %1 block %3 axis %2 touch probe already deflected, edge polarity not possible
Sinumerik Alarm 21700 Channel %1 block %3 axis %2 touch probe already deflected, edge polarity not possible Parameters: %1 = Channel number %2 = Axis name, spindle number %3 =…
Sinumerik Alarm 21670 Channel %1 block %2 illegal change of tool direction with $AA_TOFF active
Sinumerik Alarm 21670 Channel %1 block %2 illegal change of tool direction with $AA_TOFF active Parameters: %1 = Channel number %2 = Block number, label Definitions: If an offset has…
Sinumerik Alarm 21665 Channel %1 $AA_TOFF cleared
Sinumerik Alarm 21665 Channel %1 $AA_TOFF cleared Parameters: %1 = Channel number Definitions: If the tool position is changed with RESET and $AA_TOFF is active during RESET, the position offset…
Sinumerik Alarm 21660 Channel %1 block %2 axis %3 conflict between SYNACT: $AA_OFF and CORROF
Sinumerik Alarm 21660 Channel %1 block %2 axis %3 conflict between SYNACT: $AA_OFF and CORROF Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name Definitions:…
Sinumerik Alarm 21650 Channel %1 axis %2 overlaid motion not allowed
Sinumerik Alarm 21650 Channel %1 axis %2 overlaid motion not allowed Parameters: %1 = Channel number %2 = Axis name, spindle number Definitions: An overlaid motion was requested for the…
Sinumerik Alarm 21619 Channel %1 block %2 transformation active: motion not possible
Sinumerik Alarm 21619 Channel %1 block %2 transformation active: motion not possible Parameters: %1 = Channel number %2 = Block number, label Definitions: The machine kinematics does not allow the…
Sinumerik Alarm 21618 Channel %1 as from block %2 transformation active: overlaid motion too great
Sinumerik Alarm 21618 Channel %1 as from block %2 transformation active: overlaid motion too great Parameters: %1 = Channel number %2 = Block number, label Definitions: The share of overlaid…
Sinumerik Alarm 21617 Channel %1 block %2 transformation does not allow to traverse the pole
Sinumerik Alarm 21617 Channel %1 block %2 transformation does not allow to traverse the pole Parameters: %1 = Channel number %2 = Block number, label Definitions: The preset curve passes…
Sinumerik Alarm 21616 Channel %1 block %2 overlaid motion active at transformation switchover
Sinumerik Alarm21616 Channel %1 block %2 overlaid motion active at transformation switchover Parameters: %1 = Channel number %2 = Block number, label Definitions: The overlaid motion in the BCS changes…
Sinumerik Alarm 21615 Channel %1 axis %2 taken from traverse mode to follow-up mode
Sinumerik Alarm 21615 Channel %1 axis %2 taken from traverse mode to follow-up mode Parameters: %1 = Channel number %2 = Axis name, spindle number Definitions: This axis has been…
Sinumerik Alarm 21614 Channel %1 axis %2 hardware limit switch %3
Sinumerik Alarm 21614 Channel %1 axis %2 hardware limit switch %3 Parameters: %1 = Channel number %2 = Axis name, spindle number %3 = String (+, – or +/-) Definitions:…
Sinumerik Alarm 21613 Axis %1 measuring system changing
Sinumerik Alarm 21613 Axis %1 measuring system changing Parameters: %1 = Axis name, spindle number Definitions: The measuring system for this axis is changing. Reactions: – Alarm display. Remedy: –…
Sinumerik Alarm 21612 Channel %1 axis %2 VDI signal ‘Servo enable’ reset during motion
Sinumerik Alarm 21612 Channel %1 axis %2 VDI signal ‘Servo enable’ reset during motion Parameters: %1 = Channel number %2 = Axis name, spindle number Definitions: The interface signal “Servo…
Sinumerik Alarm 21611 Channel %1 NC-controlled Extended Stop/Retract triggered
Sinumerik Alarm 21611 Channel %1 NC-controlled Extended Stop/Retract triggered Parameters: %1 = Channel number Definitions: “NC-controlled Extended Stop/Retract” triggered. Reactions: – Channel not ready. – NC Stop on alarm. –…
Sinumerik Alarm 21610 Channel %1 axis %2 encoder %3 frequency limit exceeded
Sinumerik Alarm 21610 Channel %1 axis %2 encoder %3 frequency limit exceeded Parameters: %1 = Channel number %2 = Axis name, spindle number %3 = String (encoder number) Definitions: The…
Sinumerik Alarm 21600 Monitoring for ESR active
Sinumerik Alarm 21600 Monitoring for ESR active Definitions: – Reactions: – Alarm display. – NC not ready. – All alarm reactions are delayed by one IPO cycle with this alarm….
Sinumerik Alarm 20211 Channel %1 block %3 spindle %2 support point beyond range limits
Sinumerik Alarm 20211 Channel %1 block %3 spindle %2 support point beyond range limits Parameters: %1 = Channel number %2 = Spindle number %3 = Block number, label Definitions: The…