Sinumerik Alarms
Siemens Sinumerik Alarms Errors SINUMERIK 840D/840Di/810D
Sinumerik Alarm 17095 Channel %1 block %2 invalid value
Sinumerik Alarm 17095 Channel %1 block %2 invalid value Parameters: %1 = Channel number %2 = Block number, label Definitions: An attempt was made to write an invalid value, e.g….
Sinumerik Alarm 17090 Channel %1 block %2 %3 value exceeds upper limit
Sinumerik Alarm 17090 Channel %1 block %2 %3 value exceeds upper limit Parameters: %1 = Channel number %2 = Block number, label %3 = MD Definitions: An attempt was made…
Sinumerik Alarm 17080 Channel %1 block %2 %3 value below lower limit
Sinumerik Alarm 17080 Channel %1 block %2 %3 value below lower limit Parameters: %1 = Channel number %2 = Block number, label %3 = MD Definitions: An attempt was made…
Sinumerik Alarm 17070 Channel %1 block %2 data is write-protected
Sinumerik Alarm 17070 Channel %1 block %2 data is write-protected Parameters: %1 = Channel number %2 = Block number, label Definitions: An attempt was made to write to a write-protected…
Sinumerik Alarm 17060 Channel %1 block %2 requested data area too large
Sinumerik Alarm 17060 Channel %1 block %2 requested data area too large Parameters: %1 = Channel number %2 = Block number, label Definitions: The maximum memory space of 8 KB…
Sinumerik Alarm 17055 Channel %1 block %2 GUD variable not existing
Sinumerik Alarm 17055 Channel %1 block %2 GUD variable not existing Parameters: %1 = Channel number %2 = Block number, label Definitions: The required GUD variable was not found for…
Sinumerik Alarm 17050 Channel %1 block %2 illegal value
Sinumerik Alarm 17050 Channel %1 block %2 illegal value Parameters: %1 = Channel number %2 = Block number, label Definitions: On accessing an individual frame element, a frame component other…
Sinumerik Alarm 17040 Channel %1 block %2 illegal axis index
Sinumerik Alarm 17040 Channel %1 block %2 illegal axis index Parameters: %1 = Channel number %2 = Block number, label Definitions: A read or write access has been programmed to…
Sinumerik Alarm 17030 Channel %1 block %2 illegal array index 2
Sinumerik Alarm 17030 Channel %1 block %2 illegal array index 2 Parameters: %1 = Channel number %2 = Block number, label Definitions: A read or write access has been programmed…
Sinumerik Alarm 17020 Channel %1 block %2 illegal array index 1
Sinumerik Alarm 17020 Channel %1 block %2 illegal array index 1 Parameters: %1 = Channel number %2 = Block number, label Definitions: A read or write access has been programmed…
Sinumerik Alarm 17010 Channel %1 block %2 no memory left
Sinumerik Alarm 17010 Channel %1 block %2 no memory left Parameters: %1 = Channel number %2 = Block number, label Definitions: When executing/reading files from the active working memory, it…
Sinumerik Alarm 17001 Channel %1 block %2 no memory left for tool/magazine data
Sinumerik Alarm 17001 Channel %1 block %2 no memory left for tool/magazine data Parameters: %1 = Channel number %2 = Block number, label Definitions: The number of the following tool/magazine…
Sinumerik Alarm 17000 Channel %1 block %2 maximum number of symbols exceeded
Sinumerik Alarm 17000 Channel %1 block %2 maximum number of symbols exceeded Parameters: %1 = Channel number %2 = Block number, label Definitions: The maximum number of symbols defined by…
Sinumerik Alarm 16951 Channel %1 search run in a program section that cannot be searched
Sinumerik Alarm 16951 Channel %1 search run in a program section that cannot be searched Parameters: %1 = Channel ID Definitions: With the language commands IPTRLOCK and IPTRUNLOCK, the part…
Sinumerik Alarm 16950 Channel %1 search run with hold block
Sinumerik Alarm 16950 Channel %1 search run with hold block Parameters: %1 = Channel ID Definitions: Informational alarm.The search run was not performed on the interruption block, instead, it touches…
Sinumerik Alarm 16949 Correspondence between marker of channel %1 and channel %2 is invalid.
Sinumerik Alarm 16949 Correspondence between marker of channel %1 and channel %2 is invalid. Parameters: %1 = Channel ID %2 = Channel ID Definitions: This channel defines a WAIT marker…
Sinumerik Alarm 16948 Channel %1 dependent channel %2 still active
Sinumerik Alarm 16948 Channel %1 dependent channel %2 still active Parameters: %1 = Channel ID %2 = Channel ID Definitions: This alarm is active with “Group Serupro” only. “Group Serupro”…
Sinumerik Alarm 16947 Channel %1 start via PLC is not allowed
Sinumerik Alarm 16947 Channel %1 start via PLC is not allowed Parameters: %1 = Channel ID Definitions: This alarm is active with “Group Serupro” only. “Group Serupro” is activated by…
Sinumerik Alarm 16946 Channel %1 start via START is not allowed
Sinumerik Alarm 16946 Channel %1 start via START is not allowed Parameters: %1 = Channel ID Definitions: This alarm is active with “Group Serupro” only. “Group Serupro” is activated by…
Sinumerik Alarm 16945 Channel %1 action %2 ALNX delayed up to the block end
Sinumerik Alarm 16945 Channel %1 action %2 <ALNX> delayed up to the block end Parameters: %1 = Channel ID %2 = Action number/action name Definitions: The currently executing action (e.g. dry…
Sinumerik Alarm 16944 Channel %1 action %2 ALNX not possible due to active search blocks
Sinumerik Alarm 16944 Channel %1 action %2 <ALNX> not possible due to active search blocks Parameters: %1 = Channel ID %2 = Action number/action name Definitions: The NCK is currently processing…
Sinumerik Alarm 16943 Channel %1 action %2 ALNX not possible due to ASUP
Sinumerik Alarm 16943 Channel %1 action %2 <ALNX> not possible due to ASUP Parameters: %1 = Channel ID %2 = Action number/action name Definitions: The action in the 2nd parameter was…
Sinumerik Alarm 16942 Channel %1 start program command action %2 ALNX not possible
Sinumerik Alarm 16942 Channel %1 start program command action %2 <ALNX> not possible Parameters: %1 = Channel ID %2 = Action number/action name Definitions: Currently, the alarm occurs only in combination…
Sinumerik Alarm 16941 Channel %1 action %2 ALNX rejected because no program event has been executed yet
Sinumerik Alarm 16941 Channel %1 action %2 <ALNX> rejected because no program event has been executed yet Parameters: %1 = Channel ID %2 = Action number/action name Definitions: The setting of…
Sinumerik Alarm 16940 Channel %1 action %2 ALNX wait for gear change
Sinumerik Alarm 16940 Channel %1 action %2 <ALNX> wait for gear change Parameters: %1 = Channel ID %2 = Action number/action name Definitions: Reorganization events are waiting for the end of…
Sinumerik Alarm 16939 Channel %1 action %2 rejected due to active gear change
Sinumerik Alarm 16939 Channel %1 action %2 rejected due to active gear change Parameters: %1 = Channel ID %2 = Action number/action name Definitions: Reorganization events that are possible in…
Sinumerik Alarm 16938 Channel %1 action %2 ALNX aborted due to active gear change
Sinumerik Alarm 16938 Channel %1 action %2 <ALNX> aborted due to active gear change Parameters: %1 = Channel ID %2 = Action number/action name Definitions: Reorganization events are, among others, subprogram…
Sinumerik Alarm 16937 Channel %1 action %2ALNX not possible due to program test
Sinumerik Alarm 16937 Channel %1 action %2 <ALNX> not possible due to program test Parameters: %1 = Channel ID %2 = Action number/action name Definitions: This action is not allowed as…
Sinumerik Alarm 16936 Channel %1 action %2 ALNX not possible due to active dry run
Sinumerik Alarm 16936 Channel %1 action %2 <ALNX> not possible due to active dry run Parameters: %1 = Channel ID %2 = Action number/action name Definitions: This action is not…
Sinumerik Alarm 16935 Channel %1 action %2 ALNX not possible due to search run
Sinumerik Alarm 16935 Channel %1 action %2 <ALNX> not possible due to search run Parameters: %1 = Channel ID %2 = Action number/action name Definitions: The action is not allowed…
Sinumerik Alarm 16934 Channel %1 interrupt treatment: action %2 ALNX not possible due to stop
Sinumerik Alarm 16934 Channel %1 interrupt treatment: action %2 <ALNX> not possible due to stop Parameters: %1 = Channel ID %2 = Action number/action name Definitions: Reorg events are, e.g….
Sinumerik Alarm 16933 Channel %1 interrupt treatment: action %2 ALNX not allowed in the current state
Sinumerik Alarm 16933 Channel %1 interrupt treatment: action %2 <ALNX> not allowed in the current state Parameters: %1 = Channel ID %2 = Action number/action name Definitions: If a temporary…
Sinumerik Alarm 16932 Channel %1 conflict when activating user data type %2
Sinumerik Alarm 16932 Channel %1 conflict when activating user data type %2 Parameters: %1 = Channel number %2 = Data type Definitions: The “activate user data” function (PI service _N_SETUDT)…
Sinumerik Alarm 16931 Channel %1 subprograms: action %2 maximum nesting depth exceeded
Sinumerik Alarm 16931 Channel %1 subprograms: action %2 maximum nesting depth exceeded Parameters: %1 = Channel number %2 = Action number/action name Definitions: Various actions can cause the current procedure…
Sinumerik Alarm 16930 Channel %1: preceding block and current block %2 must be separated through an executable block