Sinumerik Alarm 16928 Channel %1 interrupt treatment: action %2 not possible
Sinumerik Alarm 16928 Channel %1 interrupt treatment: action %2 not possible Parameters: %1 = Channel number %2 = Action number/action name Definitions: A program interrupt has been activated in a…
Sinumerik Alarm 16927 Channel %1 action %2 at active interrupt treatment not allowed
Sinumerik Alarm 16927 Channel %1 action %2 at active interrupt treatment not allowed Parameters: %1 = Channel number %2 = Action number/action name Definitions: This action may not be activated…
Sinumerik Alarm 16926 Channel %1 channel coordination: action %2 not allowed in block %3, marker %4 is already set
Sinumerik Alarm 16926 Channel %1 channel coordination: action %2 not allowed in block %3, marker %4 is already set Parameters: %1 = Channel number %2 = Action %3 = Block…
Sinumerik Alarm 16925 Channel %1 program control: action %2 not allowed in the current state, action %3 active
Sinumerik Alarm 16925 Channel %1 program control: action %2 not allowed in the current state, action %3 active Parameters: %1 = Channel number %2 = Action number/action name %3 =…
Sinumerik Alarm 16924 Channel %1 caution: program test modifies tool management data
Sinumerik Alarm 16924 Channel %1 caution: program test modifies tool management data Parameters: %1 = Channel number Definitions: Tool management data is changed during program testing. It is not possible…
Sinumerik Alarm 16923 Channel %1 program control: action %2 not allowed in the current state
Sinumerik Alarm 16923 Channel %1 program control: action %2 not allowed in the current state Parameters: %1 = Channel number %2 = Action number/action name Definitions: The current processing cannot…
Sinumerik Alarm 16922 Channel %1 subprograms: action %2 maximum nesting depth exceeded
Sinumerik Alarm 16922 Channel %1 subprograms: action %2 maximum nesting depth exceeded Parameters: %1 = Channel number %2 = Action number/action name Definitions: Various actions can cause the current procedure…
Sinumerik Alarm 16921 Channel %1 mode group %2 machine data: channel/mode group assignment not allowed or assigned twice
Sinumerik Alarm 16921 Channel %1 mode group %2 machine data: channel/mode group assignment not allowed or assigned twice Parameters: %1 = Channel number %2 = Mode group number Definitions: On…
Sinumerik Alarm 16920 Channel %1 action %2 is already active
Sinumerik Alarm 16920 Channel %1 action %2 is already active Parameters: %1 = Channel number %2 = Action number/action name Definitions: An identical action is still active. Reactions: – Alarm…
Sinumerik Alarm 16918 Channel %1 for action %2 all channels must be in reset state
Sinumerik Alarm 16918 Channel %1 for action %2 all channels must be in reset state Parameters: %1 = Channel number %2 = Action number/action name Definitions: All channels must be…
Sinumerik Alarm 16916 Channel %1 repositioning: action %2 not allowed in the current state
Sinumerik Alarm 16916 Channel %1 repositioning: action %2 not allowed in the current state Parameters: %1 = Channel number %2 = Action number/action name Definitions: Repositioning of block processing presently…
Sinumerik Alarm 16915 Channel %1 action %2 not allowed in the current block
Sinumerik Alarm 16915 Channel %1 action %2 not allowed in the current block Parameters: %1 = Channel number %2 = Action number/action name Definitions: If traversing blocks are interrupted by…
Sinumerik Alarm 16914 Mode group %1 channel %2 mode change: action %3 not allowed
Sinumerik Alarm 16914 Mode group %1 channel %2 mode change: action %3 not allowed Parameters: %1 = Channel number %2 = Mode group number %3 = Action number/action name Definitions:…
Sinumerik Alarm 16913 Mode group %1 channel %2 mode change: action %3 not allowed
Sinumerik Alarm 16913 Mode group %1 channel %2 mode change: action %3 not allowed Parameters: %1 = Channel number %2 = Mode group number %3 = Action number/action name Definitions:…
Sinumerik Alarm 16912 Channel %1 program control: action %2 only possible in reset state
Sinumerik Alarm 16912 Channel %1 program control: action %2 only possible in reset state Parameters: %1 = Channel number %2 = Action number/action name Definitions: This action can only be…
Sinumerik Alarm 16911 Channel %1 mode change is not allowed
Sinumerik Alarm 16911 Channel %1 mode change is not allowed Parameters: %1 = Channel number Definitions: The change from overstoring into another operating mode is not allowed. Reactions: – Alarm…
Sinumerik Alarm 16909 Channel %1 action %2 not allowed in current mode
Sinumerik Alarm 16909 Channel %1 action %2 not allowed in current mode Parameters: %1 = Channel number %2 = Action number/action name Definitions: You have to activate a different operating…
Sinumerik Alarm 16908 Channel %1 action %2 only possible in reset state or at the block end
Sinumerik Alarm 16908 Channel %1 action %2 only possible in reset state or at the block end Parameters: %1 = Channel number %2 = Action number/action name Definitions: This action…
Sinumerik Alarm 16907 Channel %1 action %2 only possible in stop state
Sinumerik Alarm 16907 Channel %1 action %2 only possible in stop state Parameters: %1 = Channel number %2 = Action number/action name Definitions: This action may only be performed in…
Sinumerik Alarm 16906 Channel %1 program control: action %2 is aborted due to an alarm
Sinumerik Alarm 16906 Channel %1 program control: action %2 is aborted due to an alarm Parameters: %1 = Channel number %2 = Action number/action name Definitions: The action was aborted…
Sinumerik Alarm 16904 Channel %1 program control: action %2 not allowed in the current state
Sinumerik Alarm 16904 Channel %1 program control: action %2 not allowed in the current state Parameters: %1 = Channel number %2 = Action number/action name Definitions: The operation (program, JOG,…
Sinumerik Alarm 16903 Channel %1 program control: action %2 not allowed in the current state
Sinumerik Alarm 16903 Channel %1 program control: action %2 not allowed in the current state Parameters: %1 = Channel number %2 = Action number/action name Definitions: The relevant action cannot…
Sinumerik Alarm 16830 Channel %1 block %2 incorrect position programmed for axis/spindle %3
Sinumerik Alarm 16830 Channel %1 block %2 incorrect position programmed for axis/spindle %3 Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name, spindle number Definitions:…
Sinumerik Alarm 16820 Channel %1 block %2 traverse instruction ACN for axis %3 not allowed
Sinumerik Alarm 16820 Channel %1 block %2 traverse instruction ACN for axis %3 not allowed Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name, spindle…
Sinumerik Alarm 16810 Channel %1 block %2 traverse instruction ACP for axis %3 not allowed
Sinumerik Alarm 16810 Channel %1 block %2 traverse instruction ACP for axis %3 not allowed Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name, spindle…
Sinumerik Alarm 16800 Channel %1 block %2 traverse instruction DC/CDC for axis %3 not allowed
Sinumerik Alarm 16800 Channel %1 block %2 traverse instruction DC/CDC for axis %3 not allowed Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name, spindle…
Sinumerik Alarm 16799 Channel %1 block %2 axis %3 is master axis and prohibits axis container rotation
Sinumerik Alarm 16799 Channel %1 block %2 axis %3 is master axis and prohibits axis container rotation Parameters: %1 = Channel number %2 = Block number, label %3 = Axis…
Sinumerik Alarm 16798 Channel %1 block %2 axis %3 is following axis and prohibits axis container rotation
Sinumerik Alarm 16798 Channel %1 block %2 axis %3 is following axis and prohibits axis container rotation Parameters: %1 = Channel number %2 = Block number, label % 3 =…
Sinumerik Alarm 16797 Channel %1 block %2 coupling is active
Sinumerik Alarm 16797 Channel %1 block %2 coupling is active Parameters: %1 = Channel number %2 = Block number, label Definitions: An operation is to be performed in which no…
Sinumerik Alarm 16796 Channel %1 block %2 coupling not defined
Sinumerik Alarm 16796 Channel %1 block %2 coupling not defined Parameters: %1 = Channel number %2 = Block number, label Definitions: A coupling is to be switched the parameters of…
Sinumerik Alarm 16795 Channel %1 block %2 string cannot be interpreted
Sinumerik Alarm 16795 Channel %1 block %2 string cannot be interpreted Parameters: %1 = Channel number %2 = Block number, label Definitions: A coupling has been switched on in which…
Sinumerik Alarm 16794 Channel %1 block %2 coupling of axis/spindle %3 prohibits reference point approach
Sinumerik Alarm 16794 Channel %1 block %2 coupling of axis/spindle %3 prohibits reference point approach Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name, spindle…
Sinumerik Alarm 16793 Channel %1 block %2 coupling of axis %3 prohibits transformation change
Sinumerik Alarm 16793 Channel %1 block %2 coupling of axis %3 prohibits transformation change Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name, spindle number…
Sinumerik Alarm 16792 Channel %1 block %2 too many couplings for axis/spindle %3
Sinumerik Alarm 16792 Channel %1 block %2 too many couplings for axis/spindle %3 Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name, spindle number Definitions:…
Sinumerik Alarm 16791 Channel %1 block %2 parameter is not relevant
Sinumerik Alarm 16791 Channel %1 block %2 parameter is not relevant Parameters: %1 = Channel number %2 = Block number, label Definitions: A coupling has been switched on in which…