Sinumerik Alarms

Siemens Sinumerik Alarms Errors SINUMERIK 840D/840Di/810D

Sinumerik Alarm 16790 Channel %1 block %2 Parameter is zero or missing

Sinumerik Alarm 16790 Channel %1 block %2 Parameter is zero or missing Parameters: %1 = Channel number %2 = Block number, label Definitions: A coupling has been switched on in…

Sinumerik Alarm 16789 Channel %1 block %2 multiple link

Sinumerik Alarm 16789 Channel %1 block %2 multiple link Parameters: %1 = Channel number %2 = Block number, label Definitions: A coupling has been switched on in which the axes/spindles…

Sinumerik Alarm 16788 Channel %1 block %2 cyclic coupling

Sinumerik Alarm 16788 Channel %1 block %2 cyclic coupling Parameters: %1 = Channel number %2 = Block number, label Definitions: A coupling has been switched on which results in a…

Sinumerik Alarm 16787 Channel %1 block %2 coupling parameter not changeable

Sinumerik Alarm 16787 Channel %1 block %2 coupling parameter not changeable Parameters: %1 = Channel number %2 = Block number, label Definitions: The specified coupling is write-protected. Therefore, the coupling…

Sinumerik Alarm 16785 Channel %1 block %2 identical spindles/axes %3

Sinumerik Alarm 16785 Channel %1 block %2 identical spindles/axes %3 Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name, spindle number Definitions: A coupling has…

Sinumerik Alarm 16783 Channel %1 block %2 master spindle/axis %3 not available

Sinumerik Alarm 16783 Channel %1 block %2 master spindle/axis %3 not available Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name, spindle number Definitions: A…

Sinumerik Alarm 16782 Channel %1 block %2 following spindle/axis %3 not available

Sinumerik Alarm 16782 Channel %1 block %2 following spindle/axis %3 not available Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name, spindle number Definitions: A…

Sinumerik Alarm 16781 Channel %1 block %2 master spindle/axis missing

Sinumerik Alarm 16781 Channel %1 block %2 master spindle/axis missing Parameters: %1 = Channel number %2 = Block number, label Definitions: The master spindle/axis has not been programmed in the…

Sinumerik Alarm 16780 Channel %1 block %2 following spindle/axis missing

Sinumerik Alarm 16780 Channel %1 block %2 following spindle/axis missing Parameters: %1 = Channel number %2 = Block number, label Definitions: The following spindle/axis has not been written in the…

Sinumerik Alarm 16779 Channel %1 block %2 coupling: too many couplings for axis %3, see active leading axis %4

Sinumerik Alarm 16779 Channel %1 block %2 coupling: too many couplings for axis %3, see active leading axis %4 Parameters: %1 = Channel number %2 = Block number, label %3…

Sinumerik Alarm 16778 Channel %1 block %2 coupling: Ring coupling at following axis %3 and leading axis %4 impermissible

Sinumerik Alarm 16778 Channel %1 block %2 coupling: Ring coupling at following axis %3 and leading axis %4 impermissible Parameters: %1 = Channel number %2 = Block number, label %3…

Sinumerik Alarm 16777 Channel %1 block %2 coupling: following axis %3 for lead axis %4 not available

Sinumerik Alarm 16777 Channel %1 block %2 coupling: following axis %3 for lead axis %4 not available Parameters: %1 = Channel number %2 = Block number, label %3 = Axis…

Sinumerik Alarm 16776 Channel %1 block %2 curve table %3 does not exist for axis %4

Sinumerik Alarm 16776 Channel %1 block %2 curve table %3 does not exist for axis %4 Parameters: %1 = Channel number %2 = Block number, label %3 = Number of…

Sinumerik Alarm 16771 Channel %1 following axis %2 overlaid movement not enabled

Sinumerik Alarm 16771 Channel %1 following axis %2 overlaid movement not enabled Parameters: %1 = Channel number %2 = Axis name, spindle number Definitions: No gear synchronization and no overlay…

Sinumerik Alarm 16771 Channel %1 following axis %2 overlaid movement not enabled

Sinumerik Alarm 16771 Channel %1 following axis %2 overlaid movement not enabled Parameters: %1 = Channel number %2 = Axis name, spindle number Definitions: No gear synchronization and no overlay…

Sinumerik Alarm 16770 Channel %1 block %2 axis %3 no measuring system available

Sinumerik Alarm 16770 Channel %1 block %2 axis %3 no measuring system available Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name, spindle number Definitions:…

Sinumerik Alarm 16763 Channel %1 block %2 axis %3 programmed speed is illegal (zero or negative)

Sinumerik Alarm 16763 Channel %1 block %2 axis %3 programmed speed is illegal (zero or negative) Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name,…

Sinumerik Alarm 16762 Channel %1 block %2 spindle %3 thread function is active

Sinumerik Alarm 16762 Channel %1 block %2 spindle %3 thread function is active Parameters: %1 = Channel number %2 = Block number, label %3 = Spindle number Definitions: Mistake in…

Sinumerik Alarm 16761 Channel %1 block %2 axis/spindle %3 not programmable in the channel

Sinumerik Alarm 16761 Channel %1 block %2 axis/spindle %3 not programmable in the channel Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name, spindle number…

Sinumerik Alarm 16760 Channel %1 block %2 axis %3 S value missing

Sinumerik Alarm 16760 Channel %1 block %2 axis %3 S value missing Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name, spindle number Definitions: No…

Sinumerik Alarm 16755 Channel %1 block %2 no stop required

Sinumerik Alarm 16755 Channel %1 block %2 no stop required Parameters: %1 = Channel number %2 = Block number, label Definitions: No Stop is needed for the programmed function. A…

Sinumerik Alarm 16750 Channel %1 block %2 axis %3 SPCON not programmed

Sinumerik Alarm 16750 Channel %1 block %2 axis %3 SPCON not programmed Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name, spindle number Definitions: For…

Sinumerik Alarm 16740 Channel %1 block %2 no geometry axis programmed

Sinumerik Alarm 16740 Channel %1 block %2 no geometry axis programmed Parameters: %1 = Channel number %2 = Block number, label Definitions: No geometry axis was programmed for tapping (G33)…

Sinumerik Alarm 16730 Channel %1 block %2 axis %3 wrong parameter

Sinumerik Alarm 16730 Channel %1 block %2 axis %3 wrong parameter Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name, spindle number Definitions: In G33…

Sinumerik Alarm 16720 Channel %1 block %2 axis %3 thread lead is zero

Sinumerik Alarm 16720 Channel %1 block %2 axis %3 thread lead is zero Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name, spindle number Definitions:…

Sinumerik Alarm 16715 Channel %1 block %2 axis %3 spindle not in standstill

Sinumerik Alarm 16715 Channel %1 block %2 axis %3 spindle not in standstill Parameters: %1 = Channel number %2 = Block number, label %3 = Spindle number Definitions: In the…

Sinumerik Alarm 16710 Channel %1 block %2 axis %3 master spindle not programmed

Sinumerik Alarm 16710 Channel %1 block %2 axis %3 master spindle not programmed Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name, spindle number Definitions:…

Sinumerik Alarm 16700 Channel %1 block %2 axis %3 invalid feed type

Sinumerik Alarm 16700 Channel %1 block %2 axis %3 invalid feed type Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name, spindle number Definitions: In…

Sinumerik Alarm 16510 Channel %1 block %2 no facing axis available

Sinumerik Alarm 16510 Channel %1 block %2 no facing axis available Parameters: %1 = Channel number %2 = Block number, label Definitions: Diameter programming has been activated with the keyword…

Sinumerik Alarm 16500 Channel %1 block %2 chamfer or rounding negative

Sinumerik Alarm 16500 Channel %1 block %2 chamfer or rounding negative Parameters: %1 = Channel number %2 = Block number, label Definitions: A negative chamfer or rounding has been programmed…

Sinumerik Alarm 16440 Channel %1 block %2 rotation programmed for non-existent geometry axis

Sinumerik Alarm 16440 Channel %1 block %2 rotation programmed for non-existent geometry axis Parameters: %1 = Channel number %2 = Block number, label Definitions: A rotation of a geometry axis…

Sinumerik Alarm 16430 Channel %1 block %2 geometry axis %3 cannot traverse as positioning axis in rotated coordinate system

Sinumerik Alarm 16430 Channel %1 block %2 geometry axis %3 cannot traverse as positioning axis in rotated coordinate system Parameters: %1 = Channel number %2 = Block number, label %3…

Sinumerik Alarm 16424 Channel %1 block %2 coordinate %3 programmed repeatedly in the block

Sinumerik Alarm 16424 Channel %1 block %2 coordinate %3 programmed repeatedly in the block Parameters: %1 = Channel number %2 = Block number, label %3 = Coordinate Definitions: It is…

Sinumerik Alarm 16423 Channel %1 block %2 angle %3 programmed repeatedly in the block

Sinumerik Alarm 16423 Channel %1 block %2 angle %3 programmed repeatedly in the block Parameters: %1 = Channel number %2 = Block number, label %3 = Angle Definitions: It is…

Sinumerik Alarm 16422 Channel %1 block %2 angle %3 programmed repeatedly in the block

Sinumerik Alarm 16422 Channel %1 block %2 angle %3 programmed repeatedly in the block Parameters: %1 = Channel number %2 = Block number, label %3 = Angle Definitions: It is…